Active in City of Sacramento (9 permits)
Raw permit filing name: ATOM CONSTRUCTION
8 issued · 8 parcels
vs 2 prior 24m
6 construction/remodel
Sum of permit job values
Application → issuance
Latest: Mar 25, 2026
Where this builder's geocoded permits cluster
Compares this builder's median days from permit application to issuance against all peer permits in City of Sacramento (trailing 5-year benchmark).
| Permit Category | Permits | Issued | Units | Declared Valuation | Builder Median Review | City Median (75th pct) | Relative Pace |
|---|---|---|---|---|---|---|---|
| 4 | 4 | — | $95,500 | 1d (n=4) | 4d (21d p75) | Within typical range | |
| 1 | 1 | — | $143,000 | — | 63d (119d p75) | — | |
| 1 | 1 | — | $6,000 | — | 5d (25d p75) | — | |
| 1 | 1 | — | $25,875 | — | 0d (0d p75) | — | |
| 1 | 1 | — | $6,462 | — | 0d (0d p75) | — | |
| 1 | 0 | — | — | — | 41d (93d p75) | — |
Click any address to open the full property dossier or inspect the official agency record
| Property / Parcel | Record & Category | Applied / Issued | Status | Valuation | Work Description & Raw Attribution |
|---|---|---|---|---|---|
| 7576 Myrtle Vista Ave City of Sacramento · APN 031-0101-009-0000 | Plumbing / water heater / sewer RES-2605897Portal ↗ | Issued Mar 25, 2026 0d review | Issued | $6,462 | AA: Sewer Service replacement or repair, Dig and Bury 80 L.F. All work subject to field inspection. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: ATOM CONSTRUCTION |
| 2801 Muir Way City of Sacramento · APN 012-0102-001-0000 | Remodel / interior alteration RES-2503727Portal ↗ | Issued Mar 5, 2025 9d review | Finaled | $15,000 | Bathroom Remodel Permit: COMPLETE BATHROOM REMODEL. RE-LOCATE TOILET. NEW CURBLESS SHOWER. Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994, are exempt).Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. REMOVE NON-BEARING WING WALL AND CHANGE STANDARD DOOR TO A POCKET DOOR. NON STRUCTURAL REMODEL. ALL WORK SUBJECT TO FIELD INSPECTION. Filed as: ATOM CONSTRUCTION |
| 208 Bonfield Way City of Sacramento · APN 237-0450-003-0000 | Pool / spa RES-2408790Portal ↗ | Issued Apr 23, 2024 0d review | Finaled | $6,000 | Pool Demo Permit: DEMO POOL. PUNCH TWO HOLES FOR DRAINAGE AT SHALLOW AND DEEP PART OF POOL. DISCONNECT ALL ELECTRICAL AND PLUMBING SERVICING THE POOL. FILL IN WITH CONCRETE/ROCKS/PLASTER. LAST 18" NEEDS TO BE FILLED WITH DIRT. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: ATOM CONSTRUCTION |
| 5627 Overleaf Way City of Sacramento · APN 201-0920-045-0000 | Remodel / interior alteration RES-2223346Portal ↗ | Issued Nov 2, 2022 0d review | Finaled | $35,000 | Non-structural kitchen and 2 bathroom remodel. R&R plumbing fixtures, light fixtures, cabinet/counter, portable water re-pipe, install under cabinet lighting, painting. Bathroom (Master and Hall) - R&R cabinet/counter, plumbing fixtures, electrical lighting, portable water re-pipe, shower and painting. Master bath convert tub to shower pan. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994 are exempt). Filed as: ATOM CONSTRUCTION |
| 28 Buenvante Pl City of Sacramento · APN 201-0590-034-0000 | Remodel / interior alteration RES-1923435Portal ↗ | Issued Dec 3, 2019 0d review | Finaled | $20,000 | EXPEDITED - Remodel Master Bathroom - Replace existing shower with new, curbless type. Tub to be removed entirely. All walls to remain. Filed as: ATOM CONSTRUCTION |
| 8409 Moravian Ct City of Sacramento · APN 079-0123-009-0000 | Remodel / interior alteration RES-1905743Portal ↗ | Issued Apr 5, 2019 2d review | Finaled | $25,500 | EXPEDITED - Kitchen remodel w/ frame modifications and fixture / appliance relocation to include extension for raised subfloor into family room. New lighting, switches, & receptacles. Install new French door in family room. Smoke & Carbon Monoxide Alarms required per CRC sections R314 & R315. Water conserving fixtures are required to be installed throughout this residence per SB 407 (Residences built after January 1, 1994 are exempt). Changes in this scope require PRE-approval from Building Department. ALL work subject to field inspection, unless exempted by Code. Access to perform inspection/s must be provided by the Party requesting the inspection. Filed as: ATOM CONSTRUCTION |
| 2711 B St City of Sacramento · APN 003-0050-010-0000 | Plan revision / deferred submittal COM-1820924Portal ↗ | Applied Oct 26, 2018 | Complete | — | REVISION TO COM-1811162 Occupancy load changes Filed as: ATOM CONSTRUCTION |
| 2711 B St City of Sacramento · APN 003-0050-010-0000 | Commercial tenant improvement COM-1811162Portal ↗ | Issued Jul 24, 2018 41d review | Certificate of Occupancy | $143,000 | EXPEDITED 10,5,5- convert previous B street theater to 6093 sq ft church to include mechanical, electrical, plumbing, removing/adding partition walls, classrooms, offices and finishes - PLNG-INSP REVISION TO COM-1811162 Occupancy load changes Filed as: ATOM CONSTRUCTION |
| 2750 Marty Way City of Sacramento · APN 012-0033-003-0000 | Electrical / panel RES-1702251Portal ↗ | Issued Mar 1, 2017 14d review | Finaled | $25,875 | Constructing a 460 sq ft detached deck, with 2 new 110 and 1 new 220 v electrical circuit and new spa. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. “Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994 are exempt).” Filed as: ATOM CONSTRUCTION |