Active in City of Sacramento (8 permits)
Raw permit filing aliases merged: DUY ELECTRIC · DUY ELECTRIC INC
8 issued · 6 parcels
vs 3 prior 24m
3 construction/remodel
Sum of permit job values
Application → issuance
Latest: Jul 20, 2026
Where this builder's geocoded permits cluster
Compares this builder's median days from permit application to issuance against all peer permits in City of Sacramento (trailing 5-year benchmark).
| Permit Category | Permits | Issued | Units | Declared Valuation | Builder Median Review | City Median (75th pct) | Relative Pace |
|---|---|---|---|---|---|---|---|
| 5 | 5 | 1 | $14,401 | 0d (n=5) | 0d (0d p75) | Within typical range | |
| 1 | 1 | — | $135,066 | — | 42d (83d p75) | — | |
| 1 | 1 | — | $70,000 | — | 4d (21d p75) | — | |
| 1 | 1 | — | $226,980 | — | 63d (119d p75) | — |
Click any address to open the full property dossier or inspect the official agency record
| Property / Parcel | Record & Category | Applied / Issued | Status | Valuation | Work Description & Raw Attribution |
|---|---|---|---|---|---|
| 8838 Elder Creek Rd C City of Sacramento · APN 064-0020-081-0013 | Commercial tenant improvement COM-2525322Portal ↗ | Issued Jul 20, 2026 228d review | Issued | $226,980 | EPC - "VACANT SPACE IN BUILDING "C", ROOM "C" WILL BE VACATED, AND A NEW GROW ROOM FACILITY WILL BE INSTALLED IN THE 3,492 SF. THE ROOM WILL INSTALL NEW HVAC EQUIPMENT, FANS, CEILING GROW LIGHTING AND ELECTRICAL SERVICE AS REQUIRED. ALL INTERIOR WALL, FLOOR AND CEILING FINISHES WILL REMAIN AS IS. MECHANICAL FAN COIL UNITS AND DEHUMIDIFIERS WILL BE CEILING SUPPORTED OR SET ON VERTICAL SUPPORT RACKS LATERALLY SUPPORTED BY WALL AND DIAGONALLY CABLE BRACING FROM UNISTRUT RAILS IN THE CEILING. Previous work done under permit COM -2300136 for refrence only. - PLNG-INSP Filed as: DUY ELECTRIC INC |
| 8838 Elder Creek Rd City of Sacramento · APN 064-0020-081-0013 | Remodel / interior alteration COM-2319944Portal ↗ | Issued Nov 14, 2023 56d review | Finaled | $70,000 | EPC - Power upgrade to an existing industrial building. Installation of new panels, transformers, new service, new power systems, new lighting systems, associated power and controls. Filed as: DUY ELECTRIC INC |
| 4015 Limestone Way City of Sacramento · APN 049-0470-048-0000 | Electrical / panel RES-2302188Portal ↗ | Issued Feb 6, 2023 0d review | Finaled | $4,200 1 units | AA: existing panel 100 Amps - Underground service.Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994 are exempt). Filed as: DUY ELECTRIC INC |
| 8838 Elder Creek Rd City of Sacramento · APN 064-0020-081-0013 | Addition (adds square footage) COM-2300136Portal ↗ | Issued Jan 10, 2023 6d review | Certificate of Occupancy | $135,066 | PERMIT TO COMPLETE EXPIRED COM-1813509 / CHANGE OF PERMIT HOLDER convert existing 13200 sq ft warehouse/office space to cannabis cultivation and legalize 362 sq ft mezzanine area for storage. legalize 341 sq ft mezzanine storage area above clone room and vegetation room 3. additional work to include new partition walls, electrical, mechanical, plumbing and finishes. Co2 being proposed with permit - PLNG-INSP See revision COM-1904480 - move two AC condenser units to exterior, change wall height to 12', change plant rack layout in veg room #2, 3, 4. Added drop down ceiling in storage room, added doorway to upstairs storage, change bathroom doors swing outward, specify the sizes of spacing of joist and beams in storage room and drying room EXPEDITED - REVISION TO COM-1813509: Add T-bar ceiling details to the approved plans. revision - COM-1918131 new accessible parking stall crf 9-23-2019 SEE REVISION COM-2324726: Remove Flower #3 from previous approved building plans due to power shortage Filed as: DUY ELECTRIC INC |
| 7722 Lytle St City of Sacramento · APN 052-0170-036-0000 | Electrical / panel RES-1809835Portal ↗ | Issued May 24, 2018 0d review | Finaled | $5,800 | CHANGE ELECTRICAL SERVICE PANEL REPLACE SWITCHES, PLUG AND REMOVE ALL UNAPPROVED ELECTRICAL CORD AND EXPOSED WIRING. REMOVE DOOR AND INSTALL FIRE WALL. Filed as: DUY ELECTRIC |
| 2030 Rene Ave City of Sacramento · APN 238-0171-004-0000 | Electrical / panel RES-1803762Portal ↗ | Issued Feb 28, 2018 0d review | Finaled | $2,501 | AA: existing panel 100 Amps - Overhead service, new main panel 200 Amps, Replacement weather head/masthead work, main breaker replacement. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314 Filed as: DUY ELECTRIC |
| 4095 Deerbrook Dr City of Sacramento · APN 119-0364-018-0000 | Electrical / panel RES-1611331Portal ↗ | Issued Jul 19, 2016 0d review | Finaled | $900 | E-Permit: existing panel 200 Amps - Underground service, new main panel 200 Amps, N/A weather head/masthead work. Filed as: DUY ELECTRIC |
| 604 Los Lunas Way City of Sacramento · APN 262-0333-008-0000 | Electrical / panel RES-1605319Portal ↗ | Issued Apr 8, 2016 0d review | Finaled | $1,000 | Replace main breaker Filed as: DUY ELECTRIC |