Active in City of Sacramento (10 permits) · Unincorporated Marin (1 permit)
Raw permit filing name: EQUISOLAR INC
9 issued · 10 parcels
vs 0 prior 24m
0 construction/remodel
Sum of permit job values
Application → issuance
Latest: Jun 5, 2019
Where this builder's geocoded permits cluster
Compares this builder's median days from permit application to issuance against all peer permits in City of Sacramento (trailing 5-year benchmark).
| Permit Category | Permits | Issued | Units | Declared Valuation | Builder Median Review | City Median (75th pct) | Relative Pace |
|---|---|---|---|---|---|---|---|
| 10 | 9 | — | $228,750 | 8d (n=9) | 3d (8d p75) | Within typical range | |
| 1 | 0 | — | — | — | 41d (93d p75) | — |
Click any address to open the full property dossier or inspect the official agency record
| Property / Parcel | Record & Category | Applied / Issued | Status | Valuation | Work Description & Raw Attribution |
|---|---|---|---|---|---|
| 630 N San Pedro Rd Unincorporated Marin · APN 180-231-08 | Solar / battery storage 161728Portal ↗ | Issued Jun 5, 2019 0d review | Issued | $50,000 | Pv Solar 8.900 Kw - Express Filed as: EQUISOLAR INC |
| 69 Tristan Cir City of Sacramento · APN 118-0052-006-0000 | Plan revision / deferred submittal RES-1800340Portal ↗ | Applied Jan 5, 2018 | Complete | — | OTC REVISION TO RES-1716813-Remove panel Upgrade utilize (e) 200A MSP w/ (e) 200A Main Breaker .5HR Revision Review Filed as: EQUISOLAR INC |
| 5845 61st St City of Sacramento · APN 027-0193-019-0000 | Solar / battery storage RES-1721844Portal ↗ | Issued Dec 13, 2017 15d review | Expired Permit | $20,000 | Install 3.5kw Roof Top Solar PV System. "Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994 are exempt)." Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314 Filed as: EQUISOLAR INC |
| 709 Kesner Ave City of Sacramento · APN 250-0112-022-0000 | Solar / battery storage RES-1721158Portal ↗ | Issued Nov 16, 2017 2d review | Finaled | $21,000 | 7.35kw Solar PV System. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314, Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994 are exempt).” Filed as: EQUISOLAR INC |
| 69 Tristan Cir City of Sacramento · APN 118-0052-006-0000 | Solar / battery storage RES-1716813Portal ↗ | Issued Sep 22, 2017 8d review | Finaled | $22,000 | 8.625kw Solar PV System and 225 Amp main service panel upgrade. All supply side connections, main breaker change-out, and/or panel upgrade will require a second inspection. See Revision RES-1800340 OTC REVISION TO RES-1716813-Remove panel Upgrade utilize (e) 200A MSP w/ (e) 200A Main Breaker. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314, Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994 are exempt).” Filed as: EQUISOLAR INC |
| 7160 Havenside Dr City of Sacramento · APN 031-0340-084-0000 | Solar / battery storage RES-1715650Portal ↗ | Issued Sep 22, 2017 25d review | Finaled | $19,000 | 6.9kw, 20 modules, roof mount Solar PV System, Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314, Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994 are exempt).” Filed as: EQUISOLAR INC |
| 3156 Pendleton St City of Sacramento · APN 252-0340-016-0000 | Solar / battery storage RES-1715580Portal ↗ | Applied Aug 28, 2017 | Expired Application | $10,000 | 2.76kw, 8 modules roof mount Solar PV System Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314, Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994 are exempt).” Filed as: EQUISOLAR INC |
| 7991 Newgate Dr City of Sacramento · APN 117-0584-058-0000 | Solar / battery storage RES-1715510Portal ↗ | Issued Aug 25, 2017 0d review | Expired Permit | $11,000 | Solar PV - Roof Mount Installation of a 3.012KW - DC roof mount solar with 12 modules. Carbon monoxide & Smoke alarms required. Reference 2013 CRC sections R315 & R314 “Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994 are exempt).” Filed as: EQUISOLAR INC |
| 8 Lochmoor Cir City of Sacramento · APN 118-0032-032-0000 | Solar / battery storage RES-1712161Portal ↗ | Issued Aug 2, 2017 22d review | Finaled | $21,500 | 4.550kw Solar PV System, and 0gal Solar WH System (water heater installed null). (Original scope of work should have included a new 200 amp electrical panel, missed by tech) second fee was not invoiced being invoiced as the second re-inspection fee per JPino - BRH Filed as: EQUISOLAR INC |
| 290 Christine Dr City of Sacramento · APN 263-0063-016-0000 | Solar / battery storage RES-1619393Portal ↗ | Issued Dec 16, 2016 14d review | Finaled | $22,350 | Solar PV: Installation of a 2.6 KW - DC roof mount solar with 10 modules and 10 end phase micro- inverters. Carbon monoxide & Smoke alarms required. Reference 2013 CRC sections R315 & R314 “Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994 are exempt).” Filed as: EQUISOLAR INC |
| 1530 Ascot Ave City of Sacramento · APN 215-0230-015-0000 | Solar / battery storage RES-1617540Portal ↗ | Issued Nov 4, 2016 4d review | Finaled | $31,900 | 7.11kw Solar PV System, a 200 amp main service panel. All supply side connections, main panel change outs or main breaker change outs will require a second inspection. Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994 are exempt).” Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314 Filed as: EQUISOLAR INC |