| Permit Category | Permits | Issued | Units | Declared Valuation | Builder Median Review | City Median (75th pct) | Relative Pace |
|---|---|---|---|---|---|---|---|
| 52 | 51 | — | $59,396 | 2d (n=51) | 4d (21d p75) | Within typical range | |
| 9 | 9 | — | $18,625 | 0d (n=9) | 0d (0d p75) | Within typical range | |
| 1 | 1 | — | $1,600 | — | 40d (91d p75) | — | |
| 1 | 1 | — | $20,000 | — | 14d (29d p75) | — |
Click any address to open the full property dossier or inspect the official agency record
| Property / Parcel | Record & Category | Applied / Issued | Status | Valuation | Work Description & Raw Attribution |
|---|---|---|---|---|---|
| 1001 6th St City of Sacramento · APN 006-0091-001-0000 | General repair COM-2502443Portal ↗ | Issued Feb 27, 2025 22d review | Finaled | $20,000 | EPC - Sauna heater replacement Filed as: EV ELECTRIC INC |
| 4263 Bellwether Way City of Sacramento · APN 201-1340-102-0000 | Remodel / interior alteration RES-2401656Portal ↗ | Issued Jan 30, 2024 7d review | Finaled | $700 | INSTALLATION OF FORFD CONNECT CHARGING STATION ON NEW 40A CIRCUIT USING SURFACE MOUNT 3/4' EMT WITH 2 #8 THHN AND 1 10# THHN EGC.Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314 Filed as: EV ELECTRIC INC |
| 8463 Henrik Way City of Sacramento · APN 117-1600-028-0000 | Remodel / interior alteration RES-2312275Portal ↗ | Issued Jul 27, 2023 42d review | Finaled | $650 | Installation of a Tesla Wall Connector on a new 40 amp circuit using (2) #8 awg thhn and (1) #10 EGC. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994 are exempt). ALL WORK SUBJECT TO FIELD INSPECTION. Filed as: EV ELECTRIC INC |
| 3542 Nuestra Ave City of Sacramento · APN 201-1420-044-0000 | Remodel / interior alteration RES-2312267Portal ↗ | Issued Jul 27, 2023 42d review | Finaled | $650 | Installation of a ClipperCreek Amazing E Fast 32 amp hardwired EVSE on a new 40 amp circuit using (2) #8 awg thhn and (1) #10 EGC. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994 are exempt). ALL WORK SUBJECT TO FIELD INSPECTION. Filed as: EV ELECTRIC INC |
| 5907 Camellia Ave City of Sacramento · APN 005-0202-024-0000 | Remodel / interior alteration RES-2308223Portal ↗ | Issued Jul 25, 2023 91d review | Finaled | $1,086 | Installation of a nema 14-50 outlet on a new 40 amp gfci circuit using #8 thhn. For EV Charger in existing garage. Water conserving fixtures are required to be installed throughout this structure per SB 407 (Note: Residences built after January 1, 1994 are exempt). Carbon monoxide & Smoke alarms required. Reference 2022 CRC sections R315 & R314. ALL WORK SUBJECT TO FIELD INSPECTION. Filed as: EV ELECTRIC INC |
| 1304 39th St City of Sacramento · APN 008-0196-002-0000 | Remodel / interior alteration RES-2309435Portal ↗ | Issued Jul 20, 2023 71d review | Expired Permit | $1,950 | INSTALLATION OF NEMA 14-50 ON A NEW 40 AMP GFCI CIRCUIT USING 8/3 NM CABLE. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994 are exempt). ALL WORK SUBJECT TO FIELD INSPECTION. Filed as: EV ELECTRIC INC |
| 2020 8th Ave City of Sacramento · APN 012-0315-009-0000 | Remodel / interior alteration RES-2312933Portal ↗ | Issued Jun 26, 2023 3d review | Finaled | $1,175 | INSTALLATION OF A JUISEBOX 32 CONNECTOR ON A NEW 40 AMP CIRCUIT USING 3/4" SURFACE EMT WITH #8 THHN. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994 are exempt). ALL WORK SUBJECT TO FIELD INSPECTION. Filed as: EV ELECTRIC INC |
| 3641 College Ave City of Sacramento · APN 012-0405-014-0000 | Remodel / interior alteration RES-2312438Portal ↗ | Issued Jun 23, 2023 4d review | Finaled | $1,145 | INSTALL JUICEBOX 32 CONNECTOR ON A NEW 40 AMP CIRCUIT USING 8/2 NM CABLE. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994 are exempt). ALL WORK SUBJECT TO FIELD INSPECTION. Filed as: EV ELECTRIC INC |
| 4825 Crestwood Way City of Sacramento · APN 016-0153-004-0000 | Remodel / interior alteration RES-2312271Portal ↗ | Issued Jun 23, 2023 8d review | Finaled | $930 | Installation of a nema 14-50 outlet on a 40 amp GFCI circuit using 8/3 NM cable. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994 are exempt). ALL WORK SUBJECT TO FIELD INSPECTION. Filed as: EV ELECTRIC INC |
| 125 43rd St City of Sacramento · APN 004-0124-007-0000 | Remodel / interior alteration RES-2309971Portal ↗ | Issued Jun 16, 2023 30d review | Finaled | $1,814 | INSTALLATION OF A JIUCEBOX 32 ON A NEW 40 AMP CIRCUIT USING 2, #8 AWG THHN AND 1 #10 EGC.Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994 are exempt). ALL WORK SUBJECT TO FIELD INSPECTION. Filed as: EV ELECTRIC INC |
| 1546 34th St City of Sacramento · APN 007-0294-006-0000 | Remodel / interior alteration RES-2310464Portal ↗ | Issued May 30, 2023 7d review | Finaled | $1,130 | INSTALLATION OF A CLIPPERCREEK AMAZINGE HARDWIRED ON A NEW 40 AMP CIRCUIT USING (2) #8 AWG THHN AND (1) #10 EGC. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994 are exempt). ALL WORK SUBJECT TO FIELD INSPECTION. Filed as: EV ELECTRIC INC |
| 2100 Blackridge Ave City of Sacramento · APN 225-1400-010-0000 | Remodel / interior alteration RES-2310471Portal ↗ | Issued May 26, 2023 3d review | Finaled | $2,089 | INSTALLATION OF A JUICEBOX 32 HARDWIRED ON A NEW 40 AMP CIRCUIT AND INSTALLATION OF A 120V OUTLET. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994 are exempt). ALL WORK SUBJECT TO FIELD INSPECTION. Filed as: EV ELECTRIC INC |
| 3548 David Way City of Sacramento · APN 015-0216-001-0000 | Remodel / interior alteration RES-2310115Portal ↗ | Issued May 24, 2023 6d review | Finaled | $1,290 | "Installation of a nema 14-50 outlet on a new 40 amp GFCI circuit using 8/3 NM Cable." Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994 are exempt). ALL WORK SUBJECT TO FIELD INSPECTION. Filed as: EV ELECTRIC INC |
| 1205 Nevis Ct City of Sacramento · APN 016-0291-031-0000 | Remodel / interior alteration RES-2309967Portal ↗ | Issued May 24, 2023 7d review | Finaled | $1,445 | INSTALLATION OF A JUICEBOX ON NEW 40 AMP CIRCUIT USING 2 #8 AWG THHN AND 1 #10 EGC. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994 are exempt). ALL WORK SUBJECT TO FIELD INSPECTION. Filed as: EV ELECTRIC INC |
| 390 Allaire Cir City of Sacramento · APN 201-1040-026-0000 | Remodel / interior alteration RES-2309409Portal ↗ | Issued May 12, 2023 2d review | Finaled | $825 | Installation of NEMA 14-50 outlet on a new 40 amp GFCI circuit using (2) #8 awg thhn and (1) #10 EGC. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314 Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994 are exempt).” Filed as: EV ELECTRIC INC |
| 9 La Gama Ct City of Sacramento · APN 201-1040-012-0000 | Remodel / interior alteration RES-2309289Portal ↗ | Issued May 10, 2023 1d review | Finaled | $825 | Installation of a nema 14-50 outlet on a new 40 amp GFCI circuit using (2) #8 awg thhn and (1) #10 EGC Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994 are exempt). ALL WORK SUBJECT TO FIELD INSPECTION. Filed as: EV ELECTRIC INC |
| 320 Arnold Gamble Cir City of Sacramento · APN 201-0570-063-0000 | Remodel / interior alteration RES-2308842Portal ↗ | Issued May 4, 2023 1d review | Finaled | $1,042 | Installation of a JuiceBox 32 hardwired EVSE on a new 40 amp circuit using (2) #8 awg thhn and (1) #10 EGC. Water conserving fixtures are required to be installed throughout this structure per SB 407 (Note: Residences built after January 1, 1994 are exempt). Carbon monoxide & Smoke alarms required. Reference 2022 CRC sections R315 & R314. ALL WORK SUBJECT TO FIELD INSPECTION. Filed as: EV ELECTRIC INC |
| 4325 62nd St City of Sacramento · APN 021-0237-011-0000 | Electrical / panel RES-2308431Portal ↗ | Issued Apr 27, 2023 0d review | Finaled | $3,100 | E-Permit: existing panel 100 Amps - Overhead service, new main panel 200 Amps, Replacement weather head/masthead work, main breaker replacement. Filed as: EV ELECTRIC INC |
| 3778 E Commerce Way City of Sacramento · APN 225-2830-003-0000 | Remodel / interior alteration RES-2308254Portal ↗ | Issued Apr 26, 2023 0d review | Finaled | $910 | Installation of a nema 14-50 outlet on a new 40 amp circuit using (2) #8 thhn & (1) #10 thhn EGC using existing 3/4Z conduit. Water conserving fixtures are required to be installed throughout this structure per SB 407 (Note: Residences built after January 1, 1994 are exempt). Carbon monoxide & Smoke alarms required. Reference 2022 CRC sections R315 & R314. ALL WORK SUBJECT TO FIELD INSPECTION. Filed as: EV ELECTRIC INC |
| 2847 Belle Fleur Way City of Sacramento · APN 225-1050-073-0000 | Remodel / interior alteration RES-2308251Portal ↗ | Issued Apr 26, 2023 0d review | Finaled | $750 | Installation of a nema 14-50 outlet on a new 40 amp gfci circuit using #8 thhn. Water conserving fixtures are required to be installed throughout this structure per SB 407 (Note: Residences built after January 1, 1994 are exempt). Carbon monoxide & Smoke alarms required. Reference 2022 CRC sections R315 & R314. ALL WORK SUBJECT TO FIELD INSPECTION. Filed as: EV ELECTRIC INC |
| 2048 51st Ave City of Sacramento · APN 035-0366-013-0000 | Remodel / interior alteration RES-2308242Portal ↗ | Issued Apr 26, 2023 0d review | Finaled | $1,310 | Installation of a Tesla Wall Connector on a new 40 amp circuit using 8/2 NM cable. Water conserving fixtures are required to be installed throughout this structure per SB 407 (Note: Residences built after January 1, 1994 are exempt). Carbon monoxide & Smoke alarms required. Reference 2022 CRC sections R315 & R314. ALL WORK SUBJECT TO FIELD INSPECTION. Filed as: EV ELECTRIC INC |
| 120 Citrine Cir City of Sacramento · APN 225-1260-034-0000 | Remodel / interior alteration RES-2308212Portal ↗ | Issued Apr 26, 2023 1d review | Finaled | $775 | Installation of a Tesla Wall Connector on a new 40 amp circuit using (2) #8 awg thhn and (1) #10 EGC. Water conserving fixtures are required to be installed throughout this structure per SB 407 (Note: Residences built after January 1, 1994 are exempt). Carbon monoxide & Smoke alarms required. Reference 2022 CRC sections R315 & R314. ALL WORK SUBJECT TO FIELD INSPECTION. Filed as: EV ELECTRIC INC |
| 1545 University Ave City of Sacramento · APN 295-0460-002-0000 | Remodel / interior alteration RES-2308209Portal ↗ | Issued Apr 26, 2023 1d review | Finaled | $1,835 | Installation of a nema 6-50 outlet on a new 40 amp GFCI circuit using 8/2 NM cable. Installation of a 120v GFCI outlet on a new 20 amp circuit. Water conserving fixtures are required to be installed throughout this structure per SB 407 (Note: Residences built after January 1, 1994 are exempt). Carbon monoxide & Smoke alarms required. Reference 2022 CRC sections R315 & R314. ALL WORK SUBJECT TO FIELD INSPECTION. Filed as: EV ELECTRIC INC |
| 2006 T St City of Sacramento · APN 010-0390-018-0000 | Remodel / interior alteration RES-2308171Portal ↗ | Issued Apr 25, 2023 0d review | Finaled | $650 | Installation of a ClipperCreek HCS-40 on a new 40 amp circuit using 8/2 NM cable. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. ALL WORK SUBJECT TO FIELD INSPECTION Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994, are exempt). Filed as: EV ELECTRIC INC |
| 35 Okeefe Ct City of Sacramento · APN 201-1190-073-0000 | Remodel / interior alteration RES-2308167Portal ↗ | Issued Apr 25, 2023 0d review | Finaled | $1,118 | INSTALLATION OF NEMA 14-50 OUTLET ON A 40 AMP GFCI CIRCUIT USING #8 THHN. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994 are exempt). ALL WORK SUBJECT TO FIELD INSPECTION. Filed as: EV ELECTRIC INC |