Active in City of Sacramento (7 permits)
Raw permit filing aliases merged: JAGUAR CONSTRUCTION · Jaguar Construction
7 issued · 4 parcels
vs 0 prior 24m
3 construction/remodel
Sum of permit job values
Application → issuance
Latest: May 5, 2020
Where this builder's geocoded permits cluster
Compares this builder's median days from permit application to issuance against all peer permits in City of Sacramento (trailing 5-year benchmark).
| Permit Category | Permits | Issued | Units | Declared Valuation | Builder Median Review | City Median (75th pct) | Relative Pace |
|---|---|---|---|---|---|---|---|
| 3 | 3 | — | $41,000 | 0d (n=3) | 4d (21d p75) | Within typical range | |
| 3 | 3 | — | $9,815 | 0d (n=3) | 0d (0d p75) | Within typical range | |
| 1 | 1 | — | $14,000 | — | 0d (0d p75) | — |
Click any address to open the full property dossier or inspect the official agency record
| Property / Parcel | Record & Category | Applied / Issued | Status | Valuation | Work Description & Raw Attribution |
|---|---|---|---|---|---|
| 872 Vallejo Way City of Sacramento · APN 012-0101-006-0000 | Plumbing / water heater / sewer RES-2007447Portal ↗ | Issued May 5, 2020 0d review | Finaled | $3,390 | Change-out installation of Gas - 040 gallon to Gas - Tankless, relocate to outside building, screened by the Building and any Street Views. Filed as: JAGUAR CONSTRUCTION |
| 872 Vallejo Way City of Sacramento · APN 012-0101-006-0000 | Plumbing / water heater / sewer RES-2007446Portal ↗ | Issued May 5, 2020 0d review | Finaled | $4,925 | E-Permit: Water Service replacement or repair, 20 L.F. Drain Line replacement or repair, 10 L.F. Water Re-pipe, 28 L.F. Gas Line replacement, repair, or new leg, 55 L.F. Kitchen Sink/Faucet and/or Disposal Replacement. Filed as: JAGUAR CONSTRUCTION |
| 872 Vallejo Way City of Sacramento · APN 012-0101-006-0000 | Electrical / panel RES-2007445Portal ↗ | Issued May 5, 2020 0d review | Finaled | $14,000 | E-Permit: existing panel 100 Amps - Overhead service, adding 10 outlets (120V), adding 1 outlets (240V), adding 1 exhaust fans, adding 16 recessed lighting fixtures, adding 060 Amps subpanel, rewiring 160 sq ft. Filed as: JAGUAR CONSTRUCTION |
| 5836 N St City of Sacramento · APN 008-0303-007-0000 | Remodel / interior alteration RES-2005390Portal ↗ | Issued Mar 31, 2020 1d review | Finaled | $28,000 | Non-structural kitchen & bath remodel limited to cabinet/countertop replacement, new plumbing / electrical fixtures, and finishes. Replace all electrical receptacles & switches. Non-structural replacement of all but (4) windows throughout dwelling. Smoke & Carbon Monoxide Alarms required per CRC sections R314 & R315. Water conserving fixtures are required to be installed throughout this residence per SB 407 (Residences built after January 1, 1994 are exempt). Changes in this scope require PRE-approval from Building Department. Access to perform inspection/s must be provided by the Party requesting the inspection. Filed as: JAGUAR CONSTRUCTION |
| 3222 Pilgrim Ct City of Sacramento · APN 252-0321-004-0000 | Remodel / interior alteration RES-1817987Portal ↗ | Issued Sep 14, 2018 0d review | Finaled | $5,000 | EXPEDITED - kitchen remodel to only include removing 2 non bearing walls, electrical rewire and installation of recessed can lighting. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. “Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994 are exempt).” Filed as: JAGUAR CONSTRUCTION |
| 3813 Branch St City of Sacramento · APN 251-0053-005-0000 | Plumbing / water heater / sewer RES-1814242Portal ↗ | Issued Jul 25, 2018 0d review | Finaled | $1,500 | H # 18-008737 - Water Heater Replacement ( Laundry room behind garage) 40 Gallon - Gas- Same Location ; 6- 7 sheets of Sheet Rock to be replaced within the kitchen area; Vanity w/ sink to be replaced within bathroom ; “Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994 are exempt).”Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314 Filed as: Jaguar Construction |
| 3222 Pilgrim Ct City of Sacramento · APN 252-0321-004-0000 | Remodel / interior alteration RES-1807403Portal ↗ | Issued Apr 20, 2018 0d review | Finaled | $8,000 | EXPEDITED - Convert a portion of master bedroom to a full bathroom. Window to be removed and covered up. Electrical and plumbing subject to field inspection. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314, Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994 are exempt).” Filed as: JAGUAR CONSTRUCTION |