Active in City of Sacramento (22 permits)
Raw permit filing name: JOSEPH THE HANDYMAN LLC
22 issued · 21 parcels
vs 16 prior 24m(−63%)
0 construction/remodel
Sum of permit job values
Application → issuance
Latest: Jan 29, 2026
Where this builder's geocoded permits cluster
Compares this builder's median days from permit application to issuance against all peer permits in City of Sacramento (trailing 5-year benchmark).
| Permit Category | Permits | Issued | Units | Declared Valuation | Builder Median Review | City Median (75th pct) | Relative Pace |
|---|---|---|---|---|---|---|---|
| 20 | 20 | 9 | $242,069 | 4d (n=20) | 0d (0d p75) | Above 75th pct turnaround | |
| 2 | 2 | — | $24,870 | 7d (n=2) | 0d (0d p75) | — |
Click any address to open the full property dossier or inspect the official agency record
| Property / Parcel | Record & Category | Applied / Issued | Status | Valuation | Work Description & Raw Attribution |
|---|---|---|---|---|---|
| 3230 Iberian Dr City of Sacramento · APN 225-0713-007-0000 | HVAC / heat pump RES-2601805Portal ↗ | Issued Jan 29, 2026 1d review | Finaled | $13,490 | No Duct Work Permitted. Change-out Split System to Split System. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: JOSEPH THE HANDYMAN LLC |
| 3928 U St City of Sacramento · APN 011-0107-004-0000 | HVAC / heat pump RES-2515636Portal ↗ | Issued Jul 28, 2025 4d review | Finaled | $14,995 | HVAC Permit: Change out like for like 3.5 ton, gas split system. 90% gas furnace. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: JOSEPH THE HANDYMAN LLC |
| 1917 Keith Way City of Sacramento · APN 277-0184-017-0000 | Roof replacement RES-2515025Portal ↗ | Issued Jul 21, 2025 4d review | Finaled | $13,995 | .HVAC Permit: Change out like for like 3.5 ton gas pack on roof and full duct work replacement. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: JOSEPH THE HANDYMAN LLC |
| 3212 Sweet Maple Way City of Sacramento · APN 274-0590-007-0000 | HVAC / heat pump RES-2508990Portal ↗ | Issued May 15, 2025 13d review | Finaled | $15,774 | HVAC CHANGE-OUT. "C/O 4 ton gas split system like for like." CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. No Duct Work Permitted. Change-out Split System to Split System. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. Filed as: JOSEPH THE HANDYMAN LLC |
| 7908 43rd Ave City of Sacramento · APN 038-0152-002-0000 | Roof replacement RES-2503755Portal ↗ | Issued Mar 6, 2025 9d review | Finaled | $10,875 | No Duct Work Permitted. Change-out Roof Mount to Roof Mount. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. Filed as: JOSEPH THE HANDYMAN LLC |
| 3300 37th St City of Sacramento · APN 013-0341-031-0000 | HVAC / heat pump RES-2501661Portal ↗ | Issued Jan 31, 2025 7d review | Finaled | $7,995 | Water Heater Permit: Change out 50 gallon tanked natural gas water heater and converting it toa 65 gallon heat pump tanked water heater with new electrical circuit. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: JOSEPH THE HANDYMAN LLC |
| 15 Blue Fern Ct City of Sacramento · APN 274-0570-024-0000 | HVAC / heat pump RES-2419069Portal ↗ | Issued Aug 30, 2024 3d review | Finaled | $14,990 | C/O Gas to Electric conversion 4 ton heat pump split system like for like, minor duct modifications The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: JOSEPH THE HANDYMAN LLC |
| 2622 14th St City of Sacramento · APN 009-0293-004-0000 | HVAC / heat pump RES-2416459Portal ↗ | Issued Jul 29, 2024 4d review | Finaled | $8,995 | HVAC Permit: Gas to electric conversion 3 ton, 16 SEER2, heat pump split system, like for like. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: JOSEPH THE HANDYMAN LLC |
| 4432 Euclid Ave City of Sacramento · APN 016-0131-011-0000 | HVAC / heat pump RES-2416032Portal ↗ | Issued Jul 29, 2024 7d review | Finaled | $15,820 | C/O 3 ton gas split system like for like The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: JOSEPH THE HANDYMAN LLC |
| 5 Suncloud Ct City of Sacramento · APN 117-0950-031-0000 | HVAC / heat pump RES-2414491Portal ↗ | Issued Jul 10, 2024 8d review | Finaled | $12,720 | Heat Pump and Air Handler Repalcement The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314 Filed as: JOSEPH THE HANDYMAN LLC |
| 2108 Grand Ave City of Sacramento · APN 252-0133-003-0000 | HVAC / heat pump RES-2414359Portal ↗ | Issued Jul 1, 2024 0d review | Finaled | $18,775 | Change-out w/new ducts 2 ton gas package unit. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. ALL WORK SUBJECT TO FIELD INSPECTION. Filed as: JOSEPH THE HANDYMAN LLC |
| 7885 Whisper Wood Way City of Sacramento · APN 117-0600-038-0000 | HVAC / heat pump RES-2412838Portal ↗ | Issued Jun 12, 2024 1d review | Finaled | $12,259 | No Duct Work Permitted. Change-out Split System to Split System. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. ALL WORK SUBJECT TO FIELD INSPECTION. Filed as: JOSEPH THE HANDYMAN LLC |
| 4757 69th St City of Sacramento · APN 021-0335-021-0000 | HVAC / heat pump RES-2402666Portal ↗ | Issued Feb 22, 2024 16d review | Expired Permit | $9,745 | HVAC Permit: Install 1 7K BTU wall mount mini split head. Install 1 9K BTU wall mount mini split head. Install 1 18K BTU heat pump condenser 18 seer 2 install new line set, communication cable, and drain lines. Remove existing wall AC. Remove existing wall furnace. Interior drywall patch. Exterior lap wood siding patch. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: JOSEPH THE HANDYMAN LLC |
| 4755 69th St City of Sacramento · APN 021-0335-021-0000 | HVAC / heat pump RES-2402548Portal ↗ | Issued Feb 22, 2024 17d review | Expired Permit | $10,495 | INSTALL (1) 7K BTU WALL MOUNT MINI SPLIT HEAD INSTALL (1) 9K BTU WALL MOUNT MINI SPLIT HEADINSTALL (1) 18K BTU HEAT PUMP CONDENSER 18 SEER2 INSTALL NEW LINE SET, COMMUNICATIONCABLE, AND DRAIN LINES REMOVE EXISTING WALL AC REMOVE EXISTING WALL FURNACE INTERIOR DRYWALL PATCH EXTERIOR LAP WOOD SIDING PATCH The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314 Filed as: JOSEPH THE HANDYMAN LLC |
| 3924 Natoma Way City of Sacramento · APN 252-0023-037-0000 | HVAC / heat pump RES-2323416Portal ↗ | Issued Nov 2, 2023 0d review | Finaled | $4,180 | HVAC Permit: Change of gas dual wall, 50K BTUs wall furnace, like for like and same location. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: JOSEPH THE HANDYMAN LLC |
| 2445 Edna St City of Sacramento · APN 025-0242-019-0000 | HVAC / heat pump RES-2320236Portal ↗ | Issued Sep 22, 2023 0d review | Finaled | $12,000 | HVAC Permit: Package unit replacement Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: JOSEPH THE HANDYMAN LLC |
| 2188 6th Ave City of Sacramento · APN 013-0172-040-0000 | HVAC / heat pump RES-2317014Portal ↗ | Issued Aug 25, 2023 14d review | Finaled | $2,749 9 units | Water Heater Permit: Change out existing 40 gallon natural gas water heater and convert to electrical 50 gallon water heat pump. like for like. Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994, are exempt). Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: JOSEPH THE HANDYMAN LLC |
| 5001 T St City of Sacramento · APN 011-0134-001-0000 | HVAC / heat pump RES-2311809Portal ↗ | Issued Jun 13, 2023 4d review | Finaled | $13,101 | No Duct Work Permitted. Change-out Split System to Split System. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: JOSEPH THE HANDYMAN LLC |
| 5541 79th St City of Sacramento · APN 023-0303-018-0000 | HVAC / heat pump RES-2311819Portal ↗ | Issued Jun 12, 2023 3d review | Finaled | $11,947 | No Duct Work Permitted. Change-out w/new ducts Split System to Split System. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%.The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314 Filed as: JOSEPH THE HANDYMAN LLC |
| 4055 12th Ave City of Sacramento · APN 014-0244-031-0000 | HVAC / heat pump RES-2311337Portal ↗ | Issued Jun 6, 2023 1d review | Expired Permit | $9,300 | No Duct Work Permitted. Change-out Split System to Split System. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%.The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: JOSEPH THE HANDYMAN LLC |
| 8125 La Riviera Dr City of Sacramento · APN 079-0361-026-0000 | HVAC / heat pump RES-2307271Portal ↗ | Issued Apr 14, 2023 1d review | Expired Permit | $15,739 | No Duct Work Permitted. Change-out Split System to Split System. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%.REPLACE AIR HANDLER, HEAT PUMP, AND COIL LOCATED IN INDOOR CLOSET AND BACKYARD RESPECTIVLY HSOF 9 SEER 17.. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314 Filed as: JOSEPH THE HANDYMAN LLC |
| 6382 Faustino Way City of Sacramento · APN 030-0790-041-0000 | HVAC / heat pump RES-2306062Portal ↗ | Issued Mar 30, 2023 2d review | Finaled | $17,000 | No Duct Work Permitted. Change-out Split System to Split System. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. Filed as: JOSEPH THE HANDYMAN LLC |