Active in City of Sacramento (808 permits)
Raw permit filing name: PHILLIP ISAACS' CONSTRUCTION INCORPORATED
784 issued · 658 parcels
vs 139 prior 24m(−6%)
52 construction/remodel
Sum of permit job values
Application → issuance
Latest: Oct 23, 2026
Where this builder's geocoded permits cluster
Compares this builder's median days from permit application to issuance against all peer permits in City of Sacramento (trailing 5-year benchmark).
| Permit Category | Permits | Issued | Units | Declared Valuation | Builder Median Review | City Median (75th pct) | Relative Pace |
|---|---|---|---|---|---|---|---|
| 463 | 452 | — | $5,806,980 | 0d (n=452) | 1d (3d p75) | Within typical range | |
| 205 | 201 | — | $3,632,589 | 0d (n=201) | 0d (0d p75) | Within typical range | |
| 53 | 51 | — | $987,124 | 0d (n=51) | 0d (0d p75) | Within typical range | |
| 52 | 48 | — | $835,144 | 1d (n=48) | 4d (21d p75) | Within typical range | |
| 11 | 11 | — | $82,767 | 0d (n=11) | 0d (0d p75) | Within typical range | |
| 10 | 10 | — | $109,173 | 0d (n=10) | 14d (29d p75) | Faster than peer median | |
| 7 | 6 | — | $47,219 | 2d (n=6) | 0d (0d p75) | Above 75th pct turnaround | |
| 3 | 1 | — | $39,493 | — | 33d (85d p75) | — | |
| 2 | 2 | — | $73,394 | 4d (n=2) | 40d (91d p75) | — | |
| 2 | 2 | — | $38,391 | 0d (n=2) | 14d (29d p75) | — |
Multi-permit and HCD housing projects linked to this builder's permits
1 units · $80,000 · 2 permits
Click any address to open the full property dossier or inspect the official agency record
| Property / Parcel | Record & Category | Applied / Issued | Status | Valuation | Work Description & Raw Attribution |
|---|---|---|---|---|---|
| 201 Del Verde Cir 7 City of Sacramento · APN 225-0900-002-0007 | Windows / doors / siding COM-2623752Portal ↗ | Issued Oct 23, 2026 1d review | Issued | $8,334 | UNIT#7 REPLACE 2 WINDOWS & 1 PATIO DOOR. LIKE FOR LIKE IN SIZE AND LOCATION INSTALL AS RETROFITS THE EGRESS WINDOWS WILL MEET THE CODE REQUIREMENTS ENFORCED AT THE TIME THE STRUCTURE WAS PERMITTED. THE STRUCTURE WAS BUILT IN (1982). CARBON MONOXIDE & SMOKE ALARMS REQUIRED. REFERENCE CRC SECTIONS R310.1 & R311.1. ALL WORK IS SUBJECT TO FIELD INSPECTION. Filed as: PHILLIP ISAACS' CONSTRUCTION INCORPORATED |
| 2261 Swarthmore Dr City of Sacramento · APN 295-0250-018-0000 | HVAC / heat pump RES-2623210Portal ↗ | Issued Oct 16, 2026 0d review | Issued | $19,882 | No Duct Work Permitted. Change-out Split System to Furnace Only (Split System). The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. Filed as: PHILLIP ISAACS' CONSTRUCTION INCORPORATED |
| 46 Windubey Cir City of Sacramento · APN 031-0590-047-0000 | Windows / doors / siding RES-2623034Portal ↗ | Issued Oct 14, 2026 0d review | Issued | $20,600 | Window Permit: Remove and replace 4 windows and 1 patio slider. Like for like in size and location. New trim on all 13 windows and slider. Install 20' gutter. Paint entire house. The egress windows will meet the code requirements enforced at the time the structure was permitted. The structure was built in 1985. Carbon monoxide & Smoke alarms required. Reference CRC sections R310.1 & R311.1. Filed as: PHILLIP ISAACS' CONSTRUCTION INCORPORATED |
| 2251 Swarthmore Dr City of Sacramento · APN 295-0250-030-0000 | Windows / doors / siding RES-2622886Portal ↗ | Issued Oct 14, 2026 1d review | Issued | $2,110 | REPLACE 1 WINDOW RETROFIT LIKE FOR LIKE THE EGRESS WINDOWS WILL MEET THE CODE REQUIREMENTS ENFORCED AT THE TIME THE STRUCTURE WAS PERMITTED. THE STRUCTURE WAS BUILT IN (1975). CARBON MONOXIDE & SMOKE ALARMS REQUIRED. REFERENCE CRC SECTIONS R310.1 & R311.1. ALL WORK IS SUBJECT TO FIELD INSPECTION. Filed as: PHILLIP ISAACS' CONSTRUCTION INCORPORATED |
| 6201 S Land Park Dr City of Sacramento · APN 024-0272-008-0000 | Windows / doors / siding RES-2622882Portal ↗ | Issued Oct 13, 2026 0d review | Issued | $19,872 | Window/Insulation/Stucco Permit: Remove and replace 4 windows on left side of front. Like for like in size and location. Install with nail finishing method. Apply R-13 batt insulation. New 3 coat Omega acrylic stucco. Carbon monoxide & Smoke alarms required. Reference CRC sections R310.1 & R311.1. Filed as: PHILLIP ISAACS' CONSTRUCTION INCORPORATED |
| 75 Sandburg Dr City of Sacramento · APN 005-0172-012-0000 | Roof replacement RES-2621340Portal ↗ | Issued Sep 25, 2026 1d review | Issued | $20,620 | HVAC Permit: Remove existing gas/electric roof mount package unit. Install new 3 ton package heat pump. Include roof curb, plenum, in large return air. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: PHILLIP ISAACS' CONSTRUCTION INCORPORATED |
| 11 Spray Ct City of Sacramento · APN 030-0403-016-0000 | Roof replacement RES-2621218Portal ↗ | Issued Sep 24, 2026 1d review | Finaled | $29,000 | REMOVE 1 EXISTING LAYER OF COMP ROOF, DON TO ROOF DECK. INSTALL 37 SQUARES OF CERTAINTEED LANDMARK SOLARIS COOL ROOF SHINGLES. DIAMONDECK UNDERLAYMENT. NEW METAL SS REQUIRED. NEW GUTTER GUARDS OVER EXISTING GUTTERS. IN-PROGRESS INSPECTION REQUIRED IF 10 SQUARES OR GREATER. CF1R-ALT-05-E ON FILE. CF-6R-ENV-01 REQUIRED AT FINAL INSPECTION. CARBON MONOXIDE & SMOKE ALARMS REQUIRED. REFERENCE CRC SECTIONS R310.1 & R311.1. ALL WORK IS SUBJECT TO FIELD INSPECTION. Filed as: PHILLIP ISAACS' CONSTRUCTION INCORPORATED |
| 1108 Fremont Way City of Sacramento · APN 012-0062-002-0000 | Windows / doors / siding RES-2620945Portal ↗ | Issued Sep 23, 2026 2d review | Issued | $13,090 | Window Permit: Install 13 windows retrofit , like for like. The egress windows will meet the code requirements enforced at the time the structure was permitted. The structure was built in 1938. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: PHILLIP ISAACS' CONSTRUCTION INCORPORATED |
| 6721 Swenson Way City of Sacramento · APN 029-0103-009-0000 | HVAC / heat pump RES-2621068Portal ↗ | Issued Sep 22, 2026 0d review | Issued | $37,980 | Electrical/HVAC Permit: Remove existing split gas/electric HVAC system & attic insulation w/duct work. Furnish & install new split heat pump. Locate air handler in attic. Include electrical as needed to code, thermostat, line set, and A/C pad. Replace insulation with R-49 & deep bury new duct with R-8. Furnish and install one bath finishing. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: PHILLIP ISAACS' CONSTRUCTION INCORPORATED |
| 1703 Caramay Way City of Sacramento · APN 012-0041-012-0000 | Windows / doors / siding RES-2620807Portal ↗ | Issued Sep 18, 2026 0d review | Issued | $15,074 | Window Permit: Remove and replace 10 windows, like for like in size and location. Install as retrofits. The egress windows will meet the code requirements enforced at the time the structure was permitted. The structure was built in 1927. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: PHILLIP ISAACS' CONSTRUCTION INCORPORATED |
| 1128 Commons Dr City of Sacramento · APN 295-0320-010-0000 | Windows / doors / siding RES-2619735Portal ↗ | Issued Sep 9, 2026 1d review | Finaled | $45,922 | INSTALLATION OF 19 WINDOWS, LIKE FOR LIKE. THE EGRESS WINDOWS WILL MEET THE CODE REQUIREMENTS ENFORCED AT THE TIME THE STRUCTURE WAS PERMITTED. THE STRUCTURE WAS BUILT IN (1975). CARBON MONOXIDE & SMOKE ALARMS ARE REQUIRED. REFERENCE CRC SECTIONS R315 & R314. ALL WORK IS SUBJECT TO FIELD INSPECTION. Filed as: PHILLIP ISAACS' CONSTRUCTION INCORPORATED |
| 8528 Tay Way City of Sacramento · APN 078-0470-021-0000 | Windows / doors / siding RES-2619623Portal ↗ | Issued Sep 8, 2026 4d review | Finaled | $11,500 | REMOVE AND REPLACE 10 WINDOWS RETROFIT. The egress windows will meet the code requirements enforced at the time the structure was permitted. The structure was built in (2002). CARBON MONOXIDE & SMOKE ALARMS ARE REQUIRED. REFERENCE CRC SECTIONS R315 & R314. Filed as: PHILLIP ISAACS' CONSTRUCTION INCORPORATED |
| 111 Groth Cir City of Sacramento · APN 225-1380-050-0000 | Windows / doors / siding RES-2619107Portal ↗ | Issued Aug 31, 2026 0d review | Issued | $18,600 | REPLACE 14 WINDOWS, ALL LIKE FOR LIKE IN SIZE AND LOCATION, INSTALL ALL AS RETROFITS THE EGRESS WINDOWS WILL MEET THE CODE REQUIREMENTS ENFORCED AT THE TIME THE STRUCTURE WAS PERMITTED. THE STRUCTURE WAS BUILT IN (2000). CARBON MONOXIDE & SMOKE ALARMS ARE REQUIRED. REFERENCE CRC SECTIONS R315 & R314. ALL WORK IS SUBJECT TO FIELD INSPECTION. Filed as: PHILLIP ISAACS' CONSTRUCTION INCORPORATED |
| 308 Dunbarton Cir City of Sacramento · APN 295-0230-029-0000 | Windows / doors / siding RES-2618884Portal ↗ | Issued Aug 28, 2026 1d review | Withdrawn | $30,000 | REPLACE 8 WINDOW, 1 PATIO SLIDER, ALL LIKE FOR LIKE IN SIZE AND LOCATION. THE EGRESS WINDOWS WILL MEET THE CODE REQUIREMENTS ENFORCED AT THE TIME THE STRUCTURE WAS PERMITTED. THE STRUCTURE WAS BUILT IN (1976). CARBON MONOXIDE & SMOKE ALARMS ARE REQUIRED. REFERENCE CRC SECTIONS R315 & R314. ALL WORK IS SUBJECT TO FIELD INSPECTION. Filed as: PHILLIP ISAACS' CONSTRUCTION INCORPORATED |
| 841 55th St City of Sacramento · APN 008-0082-015-0000 | Windows / doors / siding RES-2617736Portal ↗ | Issued Aug 27, 2026 14d review | Issued | $44,397 | Window/Siding Permit: Install 6 windows and 1 patio slider. Install with nail finish and new siding trim. Remove existing stucco and replace with Hardie James 8 1/4" lap siding. Includes re sheeting=15 squares, 220 linear square feet. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: PHILLIP ISAACS' CONSTRUCTION INCORPORATED |
| 305 25th St City of Sacramento · APN 004-0370-013-0000 | HVAC / heat pump RES-2617942Portal ↗ | Issued Aug 26, 2026 9d review | Issued | $14,612 | Replace existing ground mount gas/electric Package HVAC unit with new package heat pump in same location. New disconnect and thermostat. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314 Filed as: PHILLIP ISAACS' CONSTRUCTION INCORPORATED |
| 7040 Wavecrest Way City of Sacramento · APN 030-0640-048-0000 | Windows / doors / siding RES-2617402Portal ↗ | Issued Aug 11, 2026 0d review | Finaled | $6,617 | Window Permit: Remove and replace 4 windows, like for like, in size and location. Install with nail finish and trim board. The egress windows will meet the code requirements enforced at the time the structure was permitted. The structure was built in 1979. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: PHILLIP ISAACS' CONSTRUCTION INCORPORATED |
| 5931 Wymore Way City of Sacramento · APN 024-0202-008-0000 | Windows / doors / siding RES-2616961Portal ↗ | Issued Aug 6, 2026 1d review | Issued | $15,757 | Window Permit: Install 9 windows and 1 sliding glass door like for like. The egress windows will meet the code requirements enforced at the time the structure was permitted. The structure was built in 1957. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: PHILLIP ISAACS' CONSTRUCTION INCORPORATED |
| 4911 Brand Way City of Sacramento · APN 004-0093-019-0000 | Electrical / panel RES-2615908Portal ↗ | Issued Jul 27, 2026 3d review | Finaled | $14,885 | Window Permit: Replace four windows with new Milgard Tuscany white vinyl units: front bedroom gets a 3 panel with grids and a 2 panel slider with lowered sill for egress, bathroom gets a tempered single hung with clear top and satin etch bottom, and rear bedroom gets a 3 panel slider with sill lowered for egress (may need 1/3 panels). Work includes full new construction installation, removing 4–6 inches of stucco, adding flashing and wire, applying a 3 coat stucco system, and re stuccoing the south and east walls only. Replace existing 1 header like for like. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: PHILLIP ISAACS' CONSTRUCTION INCORPORATED |
| 6690 Trudy Way City of Sacramento · APN 030-0173-005-0000 | Windows / doors / siding RES-2615644Portal ↗ | Issued Jul 23, 2026 1d review | Issued | $9,947 | Window Permit: Replace 4 windows and 1 patio slider, all like for like in size and location. Install as retrofits. The egress windows will meet the code requirements enforced at the time the structure was permitted. The structure was built in 1959. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: PHILLIP ISAACS' CONSTRUCTION INCORPORATED |
| 1133 57th St City of Sacramento · APN 008-0242-022-0000 | Windows / doors / siding RES-2615590Portal ↗ | Issued Jul 23, 2026 1d review | Finaled | $4,327 | Window Permit: Install 1 window and 1 sliding door. The egress windows will meet the code requirements enforced at the time the structure was permitted. The structure was built in 1948. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: PHILLIP ISAACS' CONSTRUCTION INCORPORATED |
| 501 Dunbarton Cir City of Sacramento · APN 295-0140-026-0000 | Windows / doors / siding RES-2615438Portal ↗ | Issued Jul 21, 2026 0d review | Issued | $23,769 | Window/Siding Permit: Replace 5 windows and 3 patio sliders. All like for like in size and location. 2 of the patio doors installed with nail finishing method and siding with siding T1-11 patch. All the rest are install as retrofits. The egress windows will meet the code requirements enforced at the time the structure was permitted. The structure was built in 1976. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: PHILLIP ISAACS' CONSTRUCTION INCORPORATED |
| 3654 Far Niente Way City of Sacramento · APN 225-1160-072-0000 | Windows / doors / siding RES-2614040Portal ↗ | Issued Jul 6, 2026 4d review | Issued | $12,668 | REMOVE AND REPLACE 11 WINDOWS LIKE FOR LIKE. NO OPERATIONS CHANGING. The egress windows will meet the code requirements enforced at the time the structure was permitted. The structure was built in 2000. CARBON MONOXIDE & SMOKE ALARMS ARE REQUIRED. REFERENCE CRC SECTIONS R315 & R314. Filed as: PHILLIP ISAACS' CONSTRUCTION INCORPORATED |
| 2546 Campden Way City of Sacramento · APN 274-0460-040-0000 | Windows / doors / siding RES-2612000Portal ↗ | Issued Jun 10, 2026 0d review | Finaled | $23,095 | REMOVE AND REPLACE 12 WINDOWS LIKE FOR LIKE WITH A RETRO FIT INSTALLATION. REMOVE AND REPLACE 2 PATIO DOORS LIKE FOR LIKE WITHA RETRO FIT INSTALLATION. CARBON MONOXIDE & SMOKE ALARMS ARE REQUIRED. REFERENCE CRC SECTIONS R315 & R314. The egress windows will meet the code requirements enforced at the time the structure was permitted. The structure was built in 1999. Filed as: PHILLIP ISAACS' CONSTRUCTION INCORPORATED |
| 401 Lampasas Ave City of Sacramento · APN 263-0161-016-0000 | Roof replacement RES-2611944Portal ↗ | Issued Jun 9, 2026 0d review | Finaled | $23,475 | HVAC Permit; Replace existing roof mount HVA with new roof mount gas/electric HVAC. Enlarge return air duct to 20 x 30. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: PHILLIP ISAACS' CONSTRUCTION INCORPORATED |