Active in City of Sacramento (35 permits)
Raw permit filing aliases merged: SURE BUILT CONSTRUCTION · SURE BUILT CONSTRUCTION INC
32 issued · 26 parcels
vs 7 prior 24m
19 construction/remodel
Sum of permit job values
Application → issuance
Latest: Aug 6, 2026
Where this builder's geocoded permits cluster
Compares this builder's median days from permit application to issuance against all peer permits in City of Sacramento (trailing 5-year benchmark).
| Permit Category | Permits | Issued | Units | Declared Valuation | Builder Median Review | City Median (75th pct) | Relative Pace |
|---|---|---|---|---|---|---|---|
| 13 | 12 | — | $532,842 | 0d (n=12) | 4d (21d p75) | Within typical range | |
| 12 | 10 | — | $264,797 | 0d (n=10) | 0d (0d p75) | Within typical range | |
| 3 | 3 | — | $96,382 | 55d (n=3) | 42d (83d p75) | Within typical range | |
| 3 | 3 | — | $11,237 | 0d (n=3) | 0d (0d p75) | Within typical range | |
| 2 | 2 | — | $218,000 | 125d (n=2) | 63d (119d p75) | — | |
| 1 | 1 | — | $20,000 | — | 1d (7d p75) | — | |
| 1 | 1 | — | $19,000 | — | 0d (0d p75) | — |
Multi-permit and HCD housing projects linked to this builder's permits
Click any address to open the full property dossier or inspect the official agency record
| Property / Parcel | Record & Category | Applied / Issued | Status | Valuation | Work Description & Raw Attribution |
|---|---|---|---|---|---|
| 6154 2nd Ave City of Sacramento · APN 011-0281-007-0000 | Addition (adds square footage) RES-2615593Portal ↗ | Issued Aug 6, 2026 15d review | Issued | $16,382 | EPC - EXPEDITED - SCOPE OF WORK IS LIMITED TO ADDITION OF BATH 52 SQ.FT. CONVERT EXISTING STORAGE INTO POOL ROOM. NEW TANKLESS WATER HEATER, MINI SPLIT SYSTEM AND REMOVAL OF EXISTING DECK. Carbon monoxide & Smoke alarms are required. Reference CRC sections R315 & R314. Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994 are exempt). All work subject to field inspections. REVISION RES-2622082: UPDATING THE SEWER CONNECTION AND ADDING SEWER CONNECTION DETAIL TO SHEET A-0005 Filed as: SURE BUILT CONSTRUCTION INC |
| 2404 24th St City of Sacramento · APN 010-0223-010-0000 | Remodel / interior alteration RES-2606067Portal ↗ | Issued Mar 26, 2026 0d review | Finaled | $7,500 | Remodel Permit: Convert unpermitted living space back to single car garage Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: SURE BUILT CONSTRUCTION INC |
| 3647 Rio Loma Way City of Sacramento · APN 225-0842-019-0000 | Remodel / interior alteration RES-2601947Portal ↗ | Issued Feb 19, 2026 21d review | Finaled | $10,000 | EPC - Kitchen Layout change and add footings. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994, are exempt). Filed as: SURE BUILT CONSTRUCTION INC |
| 3636 Rio Loma Way City of Sacramento · APN 225-0841-019-0000 | Plumbing / water heater / sewer RES-2527241Portal ↗ | Issued Dec 23, 2025 0d review | Finaled | $4,563 | E-Permit: Water Service replacement or repair, 35 L.F. Water Re-pipe, 40 L.F. Filed as: SURE BUILT CONSTRUCTION INC |
| 3647 Rio Loma Way City of Sacramento · APN 225-0842-019-0000 | Remodel / interior alteration RES-2516477Portal ↗ | Issued Aug 7, 2025 1d review | Finaled | $45,000 | Kitchen Remodel Permit: Update electrical and plumbing per code. New cabinetry, new flooring, counter tops, backsplash, tile, and light fixtures. Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994, are exempt). Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: SURE BUILT CONSTRUCTION INC |
| 7040 Wavecrest Way City of Sacramento · APN 030-0640-048-0000 | Addition (adds square footage) RES-2411232Portal ↗ | Issued Jul 16, 2024 55d review | Finaled | $45,000 | EPC - Kitchen remodel with 15 sf addition to align interior wall. Significant ceiling framing alterations with additional support roof rafters above. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314, Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994 are exempt).” Filed as: SURE BUILT CONSTRUCTION INC |
| 1963 Santa Maria Way City of Sacramento · APN 293-0101-008-0000 | Remodel / interior alteration RES-2404068Portal ↗ | Issued Mar 6, 2024 9d review | Finaled | $6,500 | Demo all existing floor, wall, tile, tub and toilet and cabinetry. Remodel a guest bathroom. Update electrical per cod install floor heating, update and install new plumbing fixtures, Install new floor tile in mudroom. Filed as: SURE BUILT CONSTRUCTION INC |
| 4707 H St City of Sacramento · APN 004-0311-011-0000 | Plumbing / water heater / sewer RES-2402725Portal ↗ | Issued Feb 9, 2024 2d review | Finaled | $20,000 | Complete replacement of existing 40 gal tanked gas water heater to tankless gas water heater and relocating from inside the kitchen cabinetry to an exterior wall. Additionally, we will also be replacing the bathroom water supply lines affecting the vanity sink, toilet and tub both underneath floor joists and inside the walls. The galvanized steel pipes are corroded and water pressure is obstructed, changing them to Pex tubing. Patching drywall, texture and moldings as needed. Installing outlet for new water heater and insulating all pipes outside, below the house and in the walls. We will also be replacing the risers, replacing stop valves and supply lines. We're also re-routing a gas line previously installed by others that is exiting the home through the crawl space access which is causing access obstruction. The gas line will be re-routed through a cripple wall to stub out for future use for existing exterior fire place. Some cabinetry repair will be necessary in the kitchen as well as painting and site cleanup. Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994, are exempt).Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314 Filed as: SURE BUILT CONSTRUCTION INC |
| 3647 Rio Loma Way City of Sacramento · APN 225-0842-019-0000 | Plumbing / water heater / sewer RES-2322911Portal ↗ | Issued Oct 26, 2023 0d review | Finaled | $3,500 | Change-out installation of Gas - 040 gallon to Gas - Tankless, located inside building, screening not required. Filed as: SURE BUILT CONSTRUCTION INC |
| 8308 Grinnell Way City of Sacramento · APN 079-0194-005-0000 | Electrical / panel RES-2308085Portal ↗ | Issued Apr 24, 2023 0d review | Finaled | $5,686 | E-Permit: existing panel 200 Amps - Overhead service, new main panel 200 Amps, Replacement weather head/masthead work, main breaker replacement, adding 7 outlets (120V), adding 2 exhaust fans, adding 2 paddle fans, adding 2 ceiling mounted lighting fixtures, adding 14 recessed lighting fixtures, rewiring 140 sq ft. Filed as: SURE BUILT CONSTRUCTION INC |
| 4981 49th St City of Sacramento · APN 022-0066-008-0000 | Electrical / panel RES-2306250Portal ↗ | Issued Mar 30, 2023 0d review | Expired Permit | $3,000 | E-Permit: existing panel 125 Amps - Overhead service, new main panel 125 Amps, Reuse Existing weather head/masthead work, main breaker replacement, adding 1 exhaust fans, adding 4 recessed lighting fixtures, rewiring 50 sq ft. Filed as: SURE BUILT CONSTRUCTION INC |
| 500 N St 1209 City of Sacramento · APN 006-0310-002-0049 | Commercial tenant improvement COM-2218307Portal ↗ | Issued Mar 22, 2023 205d review | Finaled | $198,000 | EPC - Interior Remodel only of multi-family condo to include 2 bathrooms a kitchen, living room and hallway. All new plumbing, lighting, flooring, cabinetry and wall finishes. New Water heater and panel upgrade. Filed as: SURE BUILT CONSTRUCTION INC |
| 500 N St 904 City of Sacramento · APN 006-0310-002-0014 | Commercial tenant improvement COM-2218338Portal ↗ | Issued Oct 13, 2022 45d review | Finaled | $20,000 | EPC - INTERIOR REMODEL: Open doorway at existing wall for a double barn door. Re-route electrical outlet wiring over soffit. No HVAC or Sprinkler modifications required. Filed as: SURE BUILT CONSTRUCTION INC |
| 500 N St 1008 City of Sacramento · APN 006-0310-002-0028 | Plumbing / water heater / sewer COM-2213185Portal ↗ | Applied Jun 22, 2022 | Withdrawn | $4,300 | C?O Electric water heater to electric tankless water heater, C/O toilet , C/O 125amp MP to new 125 amp MP. Filed as: SURE BUILT CONSTRUCTION INC |
| 5306 Broadway City of Sacramento · APN 015-0051-002-0000 | Remodel / interior alteration RES-2207541Portal ↗ | Issued May 6, 2022 28d review | Finaled | $200,000 | EPC - Kitchen and bathroom remodel with reconfiguration of both, new electrical and plumbing to both. Removal of wall between kitchen and dining room, not a weight baring wall. New lighting, cabinetry, countertops and flooring. Relocate entry window and doorway to opposite location, some dry rot repair as needed. Gutter replacement. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314, Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994 are exempt). Filed as: SURE BUILT CONSTRUCTION INC |
| 5306 Broadway City of Sacramento · APN 015-0051-002-0000 | Plumbing / water heater / sewer RES-2127019Portal ↗ | Issued Jan 5, 2022 13d review | Expired Permit | $40,000 | Non-structural repair to front of home due to vehicle damage to include like-for-like framing, electrical, and finishes. Relocated electrical panel and replace existing water heater w/ exterior tankless. Infill garage man-door and WH closet door. Smoke & Carbon Monoxide Alarms required per CRC sections R314 & R315. Water conserving fixtures are required to be installed throughout this residence per SB 407 (Residences built after January 1, 1994 are exempt). Changes in this scope require PRE-approval from Building Department. Access to perform inspection/s must be provided by the Party requesting the inspection. Filed as: SURE BUILT CONSTRUCTION INC |
| 799 Lake Front Dr City of Sacramento · APN 031-1410-044-0000 | Roof replacement COM-2122556Portal ↗ | Issued Oct 20, 2021 1d review | Finaled | $19,000 | Tear Off - Yes, Resheet - No, 1 layer(s), 4 squares of Wood Shake Class B. In-progress inspection required if 10 squares or greater. Filed as: SURE BUILT CONSTRUCTION INC |
| 4217 Savannah Ln City of Sacramento · APN 049-0340-022-0000 | Plumbing / water heater / sewer RES-2121832Portal ↗ | Issued Oct 18, 2021 7d review | Withdrawn | $25,000 | Non-structural kitchen remodel to complete work done by others to include full kitchen remodel, remove and replace receptacles, remove and reinstall plumbing/electrical fixtures, remove and reinstall sliding door, and install new interior finishes. Smoke & Carbon Monoxide Alarms required per CRC sections R314 & R315. Water conserving fixtures are required to be installed throughout this residence per SB 407 (Residences built after January 1, 1994 are exempt). Changes in this scope require PRE-approval from Building Department. Access to perform inspection/s must be provided by the Party requesting the inspection. Filed as: SURE BUILT CONSTRUCTION INC |
| 605 Claire Ave City of Sacramento · APN 226-0061-015-0000 | Demolition RES-2122253Portal ↗ | Issued Oct 15, 2021 0d review | Expired Permit | $20,000 | Demolish and dispose of 720-sqft SFR. County approval for abandonment of septic tank required at final inspection. Filed as: SURE BUILT CONSTRUCTION INC |
| 2010 15th St City of Sacramento · APN 009-0145-011-0000 | Plumbing / water heater / sewer RES-2100950Portal ↗ | Issued Jan 15, 2021 0d review | Finaled | $45,000 | Add washer & dryer to hall bathroom, reduce size of existing shower to fit the laundry. New toilet, vanity, linen closet, lighting exhaust fan. Re-pipe drain & add vent. New valves, move water supply to next wall, repair damaged walls and siding. Close one door way. Repair window due to dry rot. Replace back existing siding. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R31. Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994 are exempt). Filed as: SURE BUILT CONSTRUCTION INC |
| 2010 15th St City of Sacramento · APN 009-0145-011-0000 | Plumbing / water heater / sewer RES-2100889Portal ↗ | Applied Jan 14, 2021 | Void | $45,000 | Add washer & dryer to hall bathroom, reduce size of existing shower to fit the laundry. New toilet, vanity, linen closet, lighting exhaust fan. Re-pipe drain & add vent. New valves, move water supply to next wall, repair damaged walls and siding. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R31. Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994 are exempt). Filed as: SURE BUILT CONSTRUCTION INC |
| 339 Zephyr Ranch Dr City of Sacramento · APN 031-0410-064-0000 | Remodel / interior alteration RES-2016450Portal ↗ | Issued Sep 17, 2020 6d review | Finaled | $18,000 | Non-Structural Hall Bath Remodel-adding (1) partition wall for shower: “Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994 are exempt).” Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314 Filed as: SURE BUILT CONSTRUCTION INC |
| 1808 T St City of Sacramento · APN 010-0091-003-0000 | Addition (adds square footage) COM-1924798Portal ↗ | Issued Apr 3, 2020 106d review | Finaled | $35,000 | EPC - Replace existing porch and balcony due to dry-rot damage. Add 30-sqft to balcony and 40-sqft to porch. Stairs to extend an additional 2ft from existing stairs. - PLNG-INSP (CONVERTED TO EPC AT 3RD CYCLE REVIEW SEE SUB-2005077) Filed as: SURE BUILT CONSTRUCTION INC |
| 369 Deer River Way City of Sacramento · APN 031-0950-006-0000 | Plumbing / water heater / sewer RES-2003571Portal ↗ | Issued Feb 28, 2020 0d review | Finaled | $7,000 | Change-out installation of Gas - 040 gallon to Gas - Tankless, located inside building, screening not required. Water heater change out. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314 Filed as: SURE BUILT CONSTRUCTION INC |
| 1808 T St City of Sacramento · APN 010-0091-003-0000 | Remodel / interior alteration COM-1924796Portal ↗ | Applied Dec 19, 2019 | Void | $35,000 | Replace existing porch and balcony due to dry-rot damage. New stairs to extend an additional 2ft from existing stairs Filed as: SURE BUILT CONSTRUCTION INC |