Active in City of Sacramento (87 permits)
Raw permit filing name: THAI'S TECHNICAL SERVICE
86 issued · 76 parcels
vs 1 prior 24m
0 construction/remodel
Sum of permit job values
Application → issuance
Latest: Jun 25, 2025
Where this builder's geocoded permits cluster
Compares this builder's median days from permit application to issuance against all peer permits in City of Sacramento (trailing 5-year benchmark).
| Permit Category | Permits | Issued | Units | Declared Valuation | Builder Median Review | City Median (75th pct) | Relative Pace |
|---|---|---|---|---|---|---|---|
| 66 | 66 | — | $123,446 | 0d (n=66) | 0d (0d p75) | Within typical range | |
| 7 | 7 | — | $63,400 | 0d (n=7) | 0d (0d p75) | Within typical range | |
| 6 | 6 | — | $18,775 | 0d (n=6) | 0d (0d p75) | Within typical range | |
| 3 | 3 | — | $7,498 | 0d (n=3) | 14d (29d p75) | Faster than peer median | |
| 3 | 2 | — | $5,311 | 0d (n=2) | 33d (85d p75) | — | |
| 1 | 1 | — | $10,290 | — | 0d (0d p75) | — | |
| 1 | 1 | — | $3,500 | — | 14d (29d p75) | — |
Click any address to open the full property dossier or inspect the official agency record
| Property / Parcel | Record & Category | Applied / Issued | Status | Valuation | Work Description & Raw Attribution |
|---|---|---|---|---|---|
| 7449 Willowwick Way City of Sacramento · APN 047-0265-010-0000 | Electrical / panel RES-2513353Portal ↗ | Issued Jun 25, 2025 0d review | Expired Permit | $2,111 | AA: existing panel 100 Amps - Overhead service, new main panel 200 Amps, Reuse Existing weather head/masthead work, main breaker replacement. Filed as: THAI'S TECHNICAL SERVICE |
| 3408 23rd Ave City of Sacramento · APN 022-0014-004-0000 | Other RES-2500376Portal ↗ | Issued Jan 7, 2025 0d review | Finaled | $2,000 | 3408 23RD AVE - UPGRADE MSP TO 125A. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. ALL WORK SUBJECT TO FIELD INSPECTION. Filed as: THAI'S TECHNICAL SERVICE |
| 4730 Natomas Blvd 140 City of Sacramento · APN 225-0040-101-0000 | General repair COM-2402401Portal ↗ | Issued Feb 1, 2024 0d review | Finaled | $3,500 | like for like replacement of grease trap Filed as: THAI'S TECHNICAL SERVICE |
| 803 Roundtree Ct City of Sacramento · APN 030-0460-030-0000 | Plumbing / water heater / sewer RES-2004351Portal ↗ | Issued Mar 10, 2020 0d review | Expired Permit | $1,900 | Emergency plumbing repair, repair leak in copper water piping and install new water electric WH. heater. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: THAI'S TECHNICAL SERVICE |
| 1305 W St City of Sacramento · APN 009-0203-021-0000 | Electrical / panel RES-2004346Portal ↗ | Issued Mar 10, 2020 0d review | Finaled | $2,501 | AA: existing panel 100 Amps - Overhead service, new main panel 200 Amps, Replacement weather head/masthead work, main breaker replacement. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314 Filed as: THAI'S TECHNICAL SERVICE |
| 780 El Macero Way City of Sacramento · APN 031-0340-041-0000 | Plumbing / water heater / sewer RES-2001993Portal ↗ | Issued Feb 5, 2020 0d review | Finaled | $1,500 | 780 EL MACERO (RHIP 08-059480) - KITCHEN AND BEDROOM GFCI OUTLET; OUTSIDE LIGHTING; FIRE RATED GARAGE DOOR TO BE REPLACED; WATER HEATER TO BE REPLACED 40 GALLON GAS .; SMOKE ALARMS AND CARBON MONOXIDE DETECTORS REQUIRED. ALL WORK IS SUBJECT TO FIELD INSPECTION. Filed as: THAI'S TECHNICAL SERVICE |
| 2228 13th St City of Sacramento · APN 009-0206-035-0000 | HVAC / heat pump RES-2001659Portal ↗ | Issued Jan 31, 2020 1d review | Expired Permit | $1,875 | Case 19-007621- TO Complete the Work on Expired RES-1906524: Unit 1237 W St - Illegal Residential Cannabis Cultivation, Restore SFR:. Return dwelling to original configuration, remove all unapproved wiring, electrical panels, lighting, grow apparatus and ducting, remove unapproved grow equipment, remove all interior partitions not part of original construction. Restore all violated fire assemblies. House to be fully scrubbed and sanitized. SMUD safety inspection upon completion of all electrical work. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314 Filed as: THAI'S TECHNICAL SERVICE |
| 1543 Dickson St City of Sacramento · APN 035-0051-014-0000 | Roof replacement RES-1903437Portal ↗ | Issued Feb 27, 2019 0d review | Finaled | $10,290 | New install/New location Split System. A unit will be installed in a new location. This unit will be fully screened behind a solid fence or alternatively behind shrubs or buildings providing screening resulting in the unit not being visible from any street views. Roof top installations will be located on back roof slopes and below ridge lines, and not visible from street views. HERS Report required at final inspection. Smoke & Carbon Monoxide Alarms required per CRC sections R314 & R315. Water conserving fixtures are required to be installed throughout this residence per SB 407 (Residences built after January 1, 1994 are exempt). Changes in this scope require PRE-approval from Building Department. ALL work subject to field inspection, unless exempted by Code. Access to perform inspection/s must be provided by the Party requesting the inspection. Filed as: THAI'S TECHNICAL SERVICE |
| 672 Alamos Ave City of Sacramento · APN 263-0103-009-0000 | Electrical / panel RES-1822533Portal ↗ | Issued Nov 26, 2018 0d review | Finaled | $1,690 | AA: existing panel 100 Amps - Overhead service, new main panel 100 Amps, Replacement weather head/masthead work. Filed as: THAI'S TECHNICAL SERVICE |
| 1543 Dickson St City of Sacramento · APN 035-0051-014-0000 | Electrical / panel RES-1821957Portal ↗ | Issued Nov 13, 2018 0d review | Expired Permit | $1,650 | AA: existing panel 060 Amps - Overhead service, new main panel 100 Amps, New Install weather head/masthead work, main breaker replacement. Filed as: THAI'S TECHNICAL SERVICE |
| 7484 53rd Ave City of Sacramento · APN 040-0240-046-0000 | Electrical / panel RES-1818704Portal ↗ | Issued Sep 25, 2018 0d review | Finaled | $2,501 | AA: existing panel 100 Amps - Overhead service, new main panel 200 Amps, Replacement weather head/masthead work, main breaker replacement.Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314 Filed as: THAI'S TECHNICAL SERVICE |
| 6041 Belleview Ave City of Sacramento · APN 038-0360-029-0000 | Electrical / panel RES-1815558Portal ↗ | Issued Aug 13, 2018 0d review | Expired Permit | $10,000 | Illegal Residential Cannabis Grow-WWOP-QUAD Fees-Restore SFR to original condition, (Job Specific Info). SMUD release upon approval of all electrical repairs. House to be fully scrubbed and sanitized. All work subject to field inspection; All repairs needed per housing checklist.Smoke alarms and Carbon Monoxide detectors required Filed as: THAI'S TECHNICAL SERVICE |
| 2600 26th Ave City of Sacramento · APN 019-0181-004-0000 | Electrical / panel RES-1805518Portal ↗ | Issued Mar 26, 2018 0d review | Finaled | $1,300 | AA: existing panel 100 Amps - Overhead service, new main panel 100 Amps, N/A weather head/masthead work, main breaker replacement. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314 Filed as: THAI'S TECHNICAL SERVICE |
| 3433 La Cadena Way City of Sacramento · APN 201-1010-037-0000 | Fire alarm / sprinkler RES-1804276Portal ↗ | Issued Mar 7, 2018 0d review | Expired Permit | $1,999 | HSG Case 17-021485 : Complete work commenced under Res-1719373 Replace front door and door jamb. Broken by forced entry, Install missing receptacle and switch outlet covers throughout. Remove the ceiling fan installed in the dining room (the outlet box is not rated for fan) and install a luminaire listed for use. Install CO2/smoke detectors where required (sleeping areas and areas immediately adjacent to sleeping areas) Install all other missing luminaires and/ or diffusers, Cap off all gas appliance stub outs that don't have appliances. Patch up all holes in ceiling/ walls and restore all fire walls to its original condition. Install finish flooring throughout. Seal around the garage man-door and install proper weather trim. Install missing frieze block on left side of the house. Rodent proofing. Secure electrical AC whip in place. Install K.O. seal at the top of service panel. Remove 125A GE breaker from Cutler-Hammer panel and blank off. Provide HERS testing CERT. Obtain permit for electrical safety inspection and plumbing gas test. “Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994 are exempt).” Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314 Filed as: THAI'S TECHNICAL SERVICE |
| 4474 Breckenridge Way City of Sacramento · APN 237-0354-018-0000 | Electrical / panel RES-1804098Portal ↗ | Issued Mar 5, 2018 0d review | Finaled | $2,111 | AA: existing panel 100 Amps - Underground service, new main panel 200 Amps, N/A weather head/masthead work, main breaker replacement. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314 Filed as: THAI'S TECHNICAL SERVICE |
| 8159 Center Pkwy City of Sacramento · APN 117-0084-013-0000 | HVAC / heat pump RES-1803174Portal ↗ | Issued Feb 20, 2018 0d review | Withdrawn | $5,000 | HSG Case 18-003824: Illegal Residential Cannabis Grow-WWOP-QUAD Fees-Restore SFR. Return dwelling to original configuration, remove all unapproved wiring, electrical panels, lighting, grow apparatus and ducting, remove unapproved grow equipment, remove all interior partitions not part of original construction. Restore all violated fire assemblies. House to be fully scrubbed and sanitized. SMUD safety inspection upon completion of all electrical work. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314 Filed as: THAI'S TECHNICAL SERVICE |
| 8016 38th Ave City of Sacramento · APN 027-0342-012-0000 | Electrical / panel RES-1723545Portal ↗ | Issued Dec 26, 2017 0d review | Expired Permit | $2,095 | AA: existing panel 100 Amps - Overhead service, new main panel 150 Amps, Replacement weather head/masthead work. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314 Filed as: THAI'S TECHNICAL SERVICE |
| 142 Mike Gartrell Cir City of Sacramento · APN 201-0550-071-0000 | Plumbing / water heater / sewer RES-1721495Portal ↗ | Issued Nov 20, 2017 0d review | Finaled | $5,000 | HSG Case 17-024712: Illegal Residential Cannabis Grow-WWOP-QUAD Fees-Restore SFR. Provide all repairs to electrical, mechanical, plumbing and fire separation / structural assemblies to restore property to previously approved use-remove all illegal wiring and obtain SMUD release for power restoration once completed. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314 Filed as: THAI'S TECHNICAL SERVICE |
| 136 Mike Gartrell Cir City of Sacramento · APN 201-0550-070-0000 | Electrical / panel RES-1721487Portal ↗ | Issued Nov 20, 2017 0d review | Finaled | $1,000 | HSG Case 17-025442: Illegal Cannabis Grow Related Electrical Repairs-WWOP-QUAD Fees: Restoration of Electrical Service to previously approved condition. An extra 125 AMP overcurrent device has been added to the house service panel without permits. SMUD shows excessive power use . Provide SMUD release after work performed passes final. Filed as: THAI'S TECHNICAL SERVICE |
| 6339 Fruitridge Rd City of Sacramento · APN 023-0251-011-0000 | Other RES-1719961Portal ↗ | Issued Oct 27, 2017 0d review | Finaled | $2,111 | C/O 2 panels from 100A to 200A. Duplex 6339 & 6341. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: THAI'S TECHNICAL SERVICE |
| 3433 La Cadena Way City of Sacramento · APN 201-1010-037-0000 | Fire alarm / sprinkler RES-1719373Portal ↗ | Issued Oct 18, 2017 0d review | Expired Permit | $1,999 | HSG Case 17-021485 : Corrective Action for SFR used for Cannabis Cultivation. Replace front door and door jamb. Broken by forced entry, Install missing receptacle and switch outlet covers throughout. Remove the ceiling fan installed in the dining room (the outlet box is not rated for fan) and install a luminaire listed for use. Install CO2/smoke detectors where required (sleeping areas and areas immediately adjacent to sleeping areas) Install all other missing luminaires and/ or diffusers, Cap off all gas appliance stub outs that don't have appliances. Patch up all holes in ceiling/ walls and restore all fire walls to its original condition. Install finish flooring throughout. Seal around the garage man-door and install proper weather trim. Install missing frieze block on left side of the house. Rodent proofing. Secure electrical AC whip in place. Install K.O. seal at the top of service panel. Remove 125A GE breaker from Cutler-Hammer panel and blank off. Provide HERS testing CERT. Obtain permit for electrical safety inspection and plumbing gas test. “Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994 are exempt).” Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314 Filed as: THAI'S TECHNICAL SERVICE |
| 2520 48th Ave City of Sacramento · APN 036-0084-006-0000 | Electrical / panel RES-1719328Portal ↗ | Issued Oct 18, 2017 0d review | Finaled | $2,501 | AA: existing panel 100 Amps - Overhead service, new main panel 200 Amps, Replacement weather head/masthead work, main breaker replacement. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314 Filed as: THAI'S TECHNICAL SERVICE |
| 1687 Wakefield Way City of Sacramento · APN 047-0031-013-0000 | Electrical / panel RES-1715830Portal ↗ | Issued Aug 30, 2017 0d review | Expired Permit | $1,200 | AA: existing panel 100 Amps - Overhead service, new main panel 200 Amps, Replacement weather head/masthead work. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314, Filed as: THAI'S TECHNICAL SERVICE |
| 2785 Mendel Way City of Sacramento · APN 225-0352-007-0000 | Electrical / panel RES-1715825Portal ↗ | Issued Aug 30, 2017 0d review | Finaled | $1,250 | AA: existing panel 100 Amps - Overhead service, new main panel 200 Amps, Replacement weather head/masthead work, main breaker replacement. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314, Filed as: THAI'S TECHNICAL SERVICE |
| 5840 Sun Valley Way City of Sacramento · APN 117-0102-003-0000 | Electrical / panel RES-1715654Portal ↗ | Issued Aug 28, 2017 0d review | Finaled | $2,500 | SMUD Disconnect / Reconnect same day-Occupied. Change Out existing panel 100 Amps - Underground service, new main panel 200 Amps, Reuse Existing Underground supply conduit. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314 Filed as: THAI'S TECHNICAL SERVICE |