Active in City of Sacramento (71 permits)
Raw permit filing name: VANGUARD ELECTRIC
70 issued · 60 parcels
vs 14 prior 24m(+279%)
Includes 2 ADU permits
Sum of permit job values
Application → issuance
Latest: Oct 13, 2026
Where this builder's geocoded permits cluster
Compares this builder's median days from permit application to issuance against all peer permits in City of Sacramento (trailing 5-year benchmark).
| Permit Category | Permits | Issued | Units | Declared Valuation | Builder Median Review | City Median (75th pct) | Relative Pace |
|---|---|---|---|---|---|---|---|
| 44 | 43 | — | $244,699 | 0d (n=43) | 0d (0d p75) | Within typical range | |
| 18 | 18 | — | $19,400 | 4d (n=18) | 4d (21d p75) | Within typical range | |
| 4 | 4 | — | $14,829 | 0d (n=4) | 0d (0d p75) | Within typical range | |
| 3 | 3 | — | $11,900 | 0d (n=3) | 0d (0d p75) | Within typical range | |
| 2 | 2 | — | $14,500 | 2d (n=2) | 97d (172d p75) | — |
Multi-permit and HCD housing projects linked to this builder's permits
1 units · $3,000 · 1 permit
1 units · $11,500 · 1 permit
Click any address to open the full property dossier or inspect the official agency record
| Property / Parcel | Record & Category | Applied / Issued | Status | Valuation | Work Description & Raw Attribution |
|---|---|---|---|---|---|
| 2017 12th St City of Sacramento · APN 009-0141-021-0000 | Electrical / panel RES-2622795Portal ↗ | Issued Oct 13, 2026 1d review | Finaled | $2,000 | ELECTRICAL PANEL UPGRADE. EXISTING IS 100A, WILL UPGRADE TO 200A. OVERHEAD SERVICE. PANEL WILL STAY IN SAME RELATIVE LOCATION. CARBON MONOXIDE & SMOKE ALARMS REQUIRED. REFERENCE CRC SECTIONS R310.1 & R311.1. ALL WORK IS SUBJECT TO FIELD INSPECTION. Filed as: VANGUARD ELECTRIC |
| 405 11th St City of Sacramento · APN 002-0115-004-0000 | Electrical / panel RES-2620148Portal ↗ | Issued Sep 22, 2026 11d review | Issued | $6,350 | ELECTRICAL PANEL UPGRADE: EXISTING IS 100A. WILL UPGRADE TO 200A. OVERHEAD SERVICE. PANEL WILL STAY IN SAME RELATIVE LOCATION. CARBON MONOXIDE & SMOKE ALARMS ARE REQUIRED. REFERENCE CRC SECTIONS R315 & R314. ALL WORK IS SUBJECT TO FIELD INSPECTION. Filed as: VANGUARD ELECTRIC |
| 405 11th St City of Sacramento · APN 002-0115-004-0000 | Electrical / panel RES-2620147Portal ↗ | Applied Sep 11, 2026 | Void | $6,350 | ELECTRICAL PANEL UPGRADE: EXISTING IS 100A. WILL UPGRADE TO 200A. OVERHEAD SERVICE. PANEL WILL STAY IN SAME RELATIVE LOCATION. CARBON MONOXIDE & SMOKE ALARMS ARE REQUIRED. REFERENCE CRC SECTIONS R315 & R314. ALL WORK IS SUBJECT TO FIELD INSPECTION. Filed as: VANGUARD ELECTRIC |
| 5417 Harte Way City of Sacramento · APN 018-0233-007-0000 | Electrical / panel RES-2617431Portal ↗ | Issued Aug 11, 2026 0d review | Finaled | $5,100 | E-Permit: existing panel 100 Amps - Overhead service, new main panel 200 Amps, Replacement weather head/masthead work, main breaker replacement. Filed as: VANGUARD ELECTRIC |
| 7287 Riverwind Way City of Sacramento · APN 031-0590-004-0000 | Remodel / interior alteration RES-2615073Portal ↗ | Issued Jul 21, 2026 6d review | Finaled | $925 | EPC - Install Enphase IQ40 hardwire on 40A breaker with 8AWG copper. The charger is installed on the inside of garage, directly behind electrical panel. Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994, are exempt). Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: VANGUARD ELECTRIC |
| 259 Brewster Ave City of Sacramento · APN 031-0370-013-0000 | Electrical / panel RES-2609167Portal ↗ | Issued May 7, 2026 0d review | Finaled | $5,100 | E-Permit: existing panel 200 Amps - Underground service, new main panel 200 Amps, N/A weather head/masthead work, main breaker replacement. Filed as: VANGUARD ELECTRIC |
| 5601 Carmela Way B City of Sacramento · APN 025-0043-018-0000 | Accessory dwelling unit (new or conversion) RES-2608709Portal ↗ | Issued May 4, 2026 4d review | Finaled | $3,000 | Gas Permit: FOR UNITS A & B- There is currently only 1 meter for both units A and B. The gas lines are existing and have been in use since the ADU was built. This permit is to separate them so they can have separate PGE meters. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: VANGUARD ELECTRIC |
| 361 Cedar River Way City of Sacramento · APN 031-0312-005-0000 | Electrical / panel RES-2606200Portal ↗ | Issued Mar 29, 2026 0d review | Finaled | $4,600 | E-Permit: existing panel 200 Amps - Underground service, new main panel 200 Amps, N/A weather head/masthead work, main breaker replacement. Filed as: VANGUARD ELECTRIC |
| 6909 Arabella Way City of Sacramento · APN 031-0360-056-0000 | Electrical / panel RES-2606199Portal ↗ | Issued Mar 29, 2026 0d review | Finaled | $4,800 | E-Permit: existing panel 200 Amps - Underground service, new main panel 200 Amps, N/A weather head/masthead work, main breaker replacement. Filed as: VANGUARD ELECTRIC |
| 579 De Mar Dr City of Sacramento · APN 031-0642-022-0000 | Electrical / panel RES-2600760Portal ↗ | Issued Jan 14, 2026 0d review | Finaled | $4,800 | E-Permit: existing panel 125 Amps - Underground service, new main panel 125 Amps, N/A weather head/masthead work, main breaker replacement. Filed as: VANGUARD ELECTRIC |
| 7419 Golden Oak Way City of Sacramento · APN 031-0182-011-0000 | Electrical / panel RES-2527473Portal ↗ | Issued Dec 30, 2025 0d review | Finaled | $4,500 | E-Permit: existing panel 125 Amps - Underground service, new main panel 200 Amps, N/A weather head/masthead work, main breaker replacement. Filed as: VANGUARD ELECTRIC |
| 2222 C St City of Sacramento · APN 003-0084-008-0000 | Remodel / interior alteration RES-2523706Portal ↗ | Issued Dec 12, 2025 30d review | Finaled | $1,400 | Install charge point home flex nacs on 40a breaker with 8 awg copper. The charger is installed on the outside of the building on the nw corner. Filed as: VANGUARD ELECTRIC |
| 1010 Roundtree Ct City of Sacramento · APN 030-0470-014-0000 | Electrical / panel RES-2524030Portal ↗ | Issued Nov 18, 2025 1d review | Finaled | $4,600 | Electrical Permit: Like for like electrical panel replacement. Remove and dispose Zinsco 125 amp meter main. Install square D 125 amp meter main. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: VANGUARD ELECTRIC |
| 3825 Haywood St City of Sacramento · APN 251-0064-007-0000 | Remodel / interior alteration RES-2523219Portal ↗ | Issued Nov 18, 2025 13d review | Finaled | $1,400 | Install tesla wall charger on 40a breaker with 8 awg copper. The charger is installed on the outside of the building, on the NE corner. Filed as: VANGUARD ELECTRIC |
| 1832 Larkin Way City of Sacramento · APN 010-0332-009-0000 | Accessory dwelling unit (new or conversion) RES-2523683Portal ↗ | Issued Nov 12, 2025 0d review | Finaled | $11,500 | Electrical Permit: This is a modification for permit RES-2523683. Currently a 100 amp electrical service. Upgrading to a 200 amp with 2 meters. The main house and ADU will each have 100 amp service with their own meter. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: VANGUARD ELECTRIC |
| 2709 23rd St City of Sacramento · APN 010-0346-020-0000 | Electrical / panel RES-2522926Portal ↗ | Issued Nov 3, 2025 0d review | Finaled | $7,225 | E-Permit: existing panel 100 Amps - Overhead service, new main panel 200 Amps, Replacement weather head/masthead work, main breaker replacement. Filed as: VANGUARD ELECTRIC |
| 2178 Lejano Way City of Sacramento · APN 225-0874-007-0000 | Remodel / interior alteration RES-2522491Portal ↗ | Issued Oct 31, 2025 4d review | Finaled | $950 | Install nema 14-50 on 40a gfci breaker with 8 awg copper to be used for ev charger. The outlet is installed inside of the garage. Filed as: VANGUARD ELECTRIC |
| 6038 Park Village St City of Sacramento · APN 035-0390-010-0000 | Remodel / interior alteration RES-2522489Portal ↗ | Issued Oct 29, 2025 2d review | Finaled | $950 | Install nema 14-5- on 40A gfci breaker with 8 awg copper to be used for ev charger. The outlet is installed inside the garage. Filed as: VANGUARD ELECTRIC |
| 6336 Seastone Way City of Sacramento · APN 030-0415-010-0000 | Electrical / panel RES-2522625Portal ↗ | Issued Oct 28, 2025 0d review | Finaled | $6,700 | E-Permit: existing panel 100 Amps - Underground service, new main panel 200 Amps, N/A weather head/masthead work, main breaker replacement. Filed as: VANGUARD ELECTRIC |
| 1016 Greenhurst Way City of Sacramento · APN 030-0272-003-0000 | Electrical / panel RES-2520974Portal ↗ | Issued Oct 4, 2025 0d review | Finaled | $4,600 | E-Permit: existing panel 125 Amps - Underground service, new main panel 125 Amps, N/A weather head/masthead work, main breaker replacement. Filed as: VANGUARD ELECTRIC |
| 3825 Haywood St City of Sacramento · APN 251-0064-007-0000 | Electrical / panel RES-2520973Portal ↗ | Issued Oct 4, 2025 0d review | Finaled | $5,250 | E-Permit: existing panel 100 Amps - Overhead service, new main panel 200 Amps, Replacement weather head/masthead work, main breaker replacement. Filed as: VANGUARD ELECTRIC |
| 5718 Kandinsky Way City of Sacramento · APN 201-1200-010-0000 | Remodel / interior alteration RES-2519262Portal ↗ | Issued Sep 18, 2025 6d review | Expired Permit | $950 | Install NEMA 14-50 40A GFCI breaker with 8 awg copper to be used for ev charger. The outlet will be installed on the wall outside of the garage. Filed as: VANGUARD ELECTRIC |
| 731 Clipper Way City of Sacramento · APN 030-0231-009-0000 | Electrical / panel RES-2519576Portal ↗ | Issued Sep 17, 2025 0d review | Finaled | $9,500 | E-Permit: existing panel 125 Amps - Underground service, new main panel 200 Amps, N/A weather head/masthead work, main breaker replacement. Filed as: VANGUARD ELECTRIC |
| 1460 64th Ave City of Sacramento · APN 047-0094-011-0000 | Electrical / panel RES-2519569Portal ↗ | Issued Sep 17, 2025 0d review | Finaled | $4,500 | E-Permit: existing panel 100 Amps - Overhead service, new main panel 200 Amps, Replacement weather head/masthead work, main breaker replacement. Filed as: VANGUARD ELECTRIC |
| 6768 Frates Way City of Sacramento · APN 030-0020-026-0000 | Electrical / panel RES-2519568Portal ↗ | Issued Sep 17, 2025 0d review | Finaled | $4,800 | E-Permit: existing panel 200 Amps - Underground service, new main panel 200 Amps, N/A weather head/masthead work, main breaker replacement. Filed as: VANGUARD ELECTRIC |