Retired / historical parcel number
Recorded at 1600 E St; 501 16th St · Records from 2018–2020
E16 Apartments FS Damper Revision
EPC - Revision to COM-1812955 to remove 2 fire-smoke dampers at level 5 trash room to match field conditions per Inspector's request
E16 Apartments - PHASED PERMIT - Revisions 2
EPC - Landscape revisions to Phased Permit COM-1816896 for E16 Apartments (main permit COM-1812955)
E16 Apartments - Live/Work Ranges
EPC - Delta 12 revision to COM-1812955 for kitchen range in live/work units
E16 Apartments - PHASED PERMIT - Revisions
EPC - Hardscape, landscape and drainage revisions for courtyard area per narrative for COM-1812955
E16 Apartments - Courtyard Revision
EPC - String lights revision at courtyard for COM-1812955
E16 Apartments - Alley Gate
EPC - Install new alley gate at Eggplant Alley
E16 Apartments - Alley Gate
EPC - Install new alley gate at Eggplant Alley
E16 Apartments - RFI #90 (Delta 8) Revision
EPC - RFI #90 (delta 8) revisions to sheets M205, M206 and P15 for mech equip at the Elevator Machine Room and rooftop condenser units
E16 Apartments revision 8 (Delta 9)
EPC - Engineering Judgement Report and Revision (delta 9) to sheet A190 to modify 2-hour exterior assembly Wall Type 01 per EJ in response to 11/19/19 Inspection Report
E16 Apartments - RFI #079 (Delta 8) Roof Railing
EPC - RFI #079 (Delta 8) revisions to sheets G106, A206, A502, A813, A814 & S704 for 42" high guardrails at two rooftop terrace egress paths & trellis framing revisions for COM-1812955
E16 Apartments RFI #083 (Delta 9) Revisions
EPC - Revision RFI #083 (Delta 9) sheet A(() - added detail 26/A990 for field conditions where roof trusses are installed too close for 2-hour wood-framed mechanical shafts to continue vertically to roof penetrations for COM-1812955 (75,960 SF for 5-story, Type IIIA wood-framed apartment building)
E16 Apartments - Deferred Glass Wall & Door
EPC - Deferred interior glass wall & door from COM-1812955 (75,960 sf 5-story, Type IIIA wood-framed apartment building)
E16 Apartments - Deferred Balconies & Railings
EPC - Deferred exterior balconies and railings from COM-1812955 (75,960 sf 5-story, Type IIIA wood-framed apartment building)
E16 Apartments RFI #055 (Delta 6) Revision
Source: City of Sacramento CDD, Issued Building Permits (Current Year) · Geography: parcel (APN as recorded on the permit) · Source updated Nov 1, 2026 · Retrieved Nov 3, 2026 · The city publishes current status without a date, so status changes are dated by the window between our snapshots.
| Report year | Project / record | Type | Entitled | Permitted | Completed | Deed-restricted |
|---|---|---|---|---|---|---|
| 2019 | E16 Apartments(COM-1812955) | 5+ · Renter | — | 95 (Jan 15, 2019) | — | — |
Source: California HCD, Housing Element Annual Progress Report — Table A2 · Geography: project (parcel or prior parcel) · Retrieved Nov 9, 2026
APN 002-0136-024-0000 · 32 permits matched by address and location
APN 427-51-36-2 · 3 permits matched by address
Matched by checking which current parcel holds each permit's mapped point, or carries its street address. This is our inference, not an official County lineage record.
Source: Sacramento County GIS, Parcels · Geography: current parcel polygons · Source updated Nov 8, 2026 · Retrieved Nov 8, 2026
Assessed values and limited building characteristics (Sacramento County Assessor)
Search by parcel number 002-0136-004-0000. Shows direct levies and special assessments.
Search the city's permit system by address or record number
County systems may not return results for a retired number. If so, use a current parcel listed above. Most recent record here: Dec 29, 2020.
EPC - RFI #055 (Delta 6) revisions to sheets A190 and A990, adding wall type 57, and new details 32/A990 and 33/A990 as an alternative 2-hr loadbearing shaft wall detail, using LP Flameblock sheathing (UL #V337) in lieu of a second layer of fire-rated gyp board. The LP Flameblock ('2-side' version) acts as both sheathing and fire protection layer of sheathing.
E16 Apartments - Revision 5 - Roof Drain
EPC - RFI #051 (Delta 6) revisions to sheet A811, adding roof drain detail 05/A811, as an alternative roof drain flashing detail for the enhanced vapor barrier that acts as a 'temporary' roofing during the winter months for COM-1812955 [Construction of 75,960 SF for 5-story, Type IIIA wood-framed apartment building (including adjacent 356 SF CMU trash enclosure)].
E16 Apartments - Deferred Roof Trusses
EPC - Deferred roof trusses from COM-1812955 (Construction of 75,960 SF for 5-story, Type IIIA wood-framed apartment building)
E16 Apartments - RFI #40 Revision
EPC Submittal - Revision to wall framing from 2x6 to 2x4 at door 134 for COM-1812955
E16 Apartments - Deferred Tie-Back Anchors
EPC - Deferred tie-back anchors from COM-1812955 E16 Apartments
E16 Apartments - Revision 3
EPC - Revision 3 per RFI #017 (Delta 5) to structural sheet S201 - deletion of footing at elevator pit
E16 Apartments - Revision 2
EPC - Revision 2 (Delta 5) to COM-1812955 - RFI 014, RFI 018 and RFI 019.1 revisions to Architectural, Structural & Electrical sheets. Modifications to elevator area, recessed bolt-on balconies and lobby leasing area
E16 Apartments - Deferred Tie Down System
EPC - Deferred tie down system from COM-1812955
E16 Apartments - Deferred Fire Alarm
EPC - Deferred fire alarm from COM-1812955 for E16 Apartments building
E16 Apartments - Deferred Sprinklers
EPC - Deferred fire sprinklers from COM-1812955 for E16 Apartments building. (Deferred U/G fire water supply review under COM-1909187)
E16 Apartments - Deferred Fire Water Supply
EPC - Deferred U/G fire water supply from COM-1812955 for E16 Apartments
E16 Apartments
OTC - Underslab plumbing revision - Change 6" branch line to (2) 4" branch lines
EPC Submittal - Deferred/Revision to Issued Permit COM-1812955 - FIRE ALARM SUBMITTAL
E16 Apartments - Revisions
EPC Submittal - Deferred/Revision to Issued Permit COM-1812955 - Revised architectural and structural details per RFI revisions. Architectural, mechanical, and electrical revisions for moving mechanical shaft for corridor HVAC from southern wing to eastern wing.
E16 Apartments - Delta 4 Revisions
EPC - Delta 4 Architectural, Structural, Mechanical & Electrical revisions per narrative for COM-1812955
EPC Submittal - Deferred/Revision to Issued Permit COM-1812955 - Underground Fire Water
EPC Submittal - Deferred/Revision to Issued Permit COM-1812955 - Revised architectural and structural details per RFI revisions. Architectural, mechanical, and electrical revisions for moving mechanical shaft for corridor HVAC from southern wing to eastern wing.
E16 Apartments
EXPEDITED - EPC Submittal - New Commercial Building - Construction of 75,960 SF for 5-story, Type IIIA wood-framed apartment building (including adjacent 356 SF CMU trash enclosure). On-site parking lot with 15 parking spaces, and small courtyard. With 95 apartments 83 single bedroom or studio units and 12 two bedroom units. Lobby, leasing office, fitness center and 15 units on the first floor with 20 units each on floors 2-5. 749 sq. ft. roof top terrace, 440 sq. ft. stair shafts and 276 sq. ft. mech. and elevator shafts. The following items are deferred from this permit: Trusses, Elevator Support, Bolt on Balconies, Tie Down System, Decorative metal railings, and fire protections systems alarm/sprinklers. GROSS SITE DEVELOPMENT AREA = 25,600 SF - PLNG-INSP
16E Apartments - PHASED PERMIT
EPC - PHASED PERMIT for grading, underground and site work including trash enclosure & east fence from COM-1812955 (75,960 gross sf, 5-story, Type IIIA apartment building) - PLNG-INSP
EPC Submittal - New Commercial Building - Construction of 75,960 SF for 5-story, Type IIIA wood-framed apartment building (including adjacent 356 SF CMU trash enclosure). On-site parking lot with 15 parking spaces, and small courtyard.