Electrical Protection
EPC - Protection of the electrical feeder conduit is being added to the basement structural drawings and the basement electrical drawings. Revision to COM-1707117, New 6-story (with partial basement) ±68,445 SF gross mixed-use building. 105-room hotel, with 1st floor restaurant; Type-IA/IIIA; Occ. R-1/A-2. Requires lot merger and demolition of existing structures. DEFERRED ITEMS, FIRE SPRINKLERS, FIRE ALARM, GREASE HOOD SUPPRESSION, STANDPIPE SYSTEM, STOREFRONT SYSTEM,OPERABLE PARTITION, CONTINUOUS ROD HOLDDOWN SYSTEM, AND ELEVATORS DEFERRED. - PLNG-INSP. Two DEMO permit were issued COM-1807391 / COM-1807394
Fort Sutter Hotel
EPC - A battery stand by power has been added to the project to power roof exhaust fans allowing for FSD's to be removed from the bath exhaust , 717.5.3 exceptions 1 & 2, Revision to COM-1707117, New 6-story (with partial basement) ±68,445 SF gross mixed-use building. 105-room hotel, with 1st floor restaurant; Type-IA/IIIA; Occ. R-1/A-2. Requires lot merger and demolition of existing structures. DEFERRED ITEMS, FIRE SPRINKLERS, FIRE ALARM, GREASE HOOD SUPPRESSION, STANDPIPE SYSTEM, STOREFRONT SYSTEM,OPERABLE PARTITION, CONTINUOUS ROD HOLDDOWN SYSTEM, AND ELEVATORS DEFERRED. - PLNG-INSP. Two DEMO permit were issued COM-1807391 / COM-1807394
Fort Sutter Hotel
EXPEDITED - EPC - Additional detail is included for a rated shaft condition as they pass a floor assemblies, interior wall intersections with the exterior walls were updated / revised. Revision to COM-1707117, New 6-story (with partial basement) ±68,445 SF gross mixed-use building. 105-room hotel, with 1st floor restaurant; Type-IA/IIIA; Occ. R-1/A-2. Requires lot merger and demolition of existing structures. DEFERRED ITEMS, FIRE SPRINKLERS, FIRE ALARM, GREASE HOOD SUPPRESSION, STANDPIPE SYSTEM, STOREFRONT SYSTEM,OPERABLE PARTITION, CONTINUOUS ROD HOLDDOWN SYSTEM, AND ELEVATORS DEFERRED. - PLNG-INSP. Two DEMO permit were issued COM-1807391 / COM-1807394
Fort Sutter Hotel
EPC - See attached matrix for the scope of the revision, Revision to COM-1707117, New 6-story (with partial basement) ±68,445 SF gross mixed-use building. 105-room hotel, with 1st floor restaurant; Type-IA/IIIA; Occ. R-1/A-2. Requires lot merger and demolition of existing structures. DEFERRED ITEMS, FIRE SPRINKLERS, FIRE ALARM, GREASE HOOD SUPPRESSION, STANDPIPE SYSTEM, STOREFRONT SYSTEM,OPERABLE PARTITION, CONTINUOUS ROD HOLDDOWN SYSTEM, AND ELEVATORS DEFERRED. - PLNG-INSP. Two DEMO permit were issued COM-1807391 / COM-1807394
Fort Sutter Hotel
EPC - the original design included belled piers as part of the foundation. Due to constructability limitations, the foundation needed to be revised to include frilled cast in place piers designed in friction. revision to COM-1707117, New 6-story (with partial basement) ±68,445 SF gross mixed-use building. 105-room hotel, with 1st floor restaurant; Type-IA/IIIA; Occ. R-1/A-2. Requires lot merger and demolition of existing structures. DEFERRED ITEMS, FIRE SPRINKLERS, FIRE ALARM, GREASE HOOD SUPPRESSION, STANDPIPE SYSTEM, STOREFRONT SYSTEM,OPERABLE PARTITION, CONTINUOUS ROD HOLDDOWN SYSTEM, AND ELEVATORS DEFERRED. - PLNG-INSP. Two DEMO permit were issued COM-1807391 / COM-1807394
Fort Sutter Hotel
EPC-New Fire Sprinkler system, manual wet standpipe, fire pump, Deferred to COM-1707117, New 6-story (with partial basement) ±68,445 SF gross mixed-use building. 105-room hotel, with 1st floor restaurant; Type-IA/IIIA; Occ. R-1/A-2. Requires lot merger and demolition of existing structures. DEFERRED ITEMS, FIRE SPRINKLERS, FIRE ALARM, GREASE HOOD SUPPRESSION, STANDPIPE SYSTEM, STOREFRONT SYSTEM,OPERABLE PARTITION, CONTINUOUS ROD HOLDDOWN SYSTEM, AND ELEVATORS DEFERRED. - PLNG-INSP. Two DEMO permit were issued COM-1807391 / COM-1807394
Fort Sutter Hotel
EPC - New 6-story (with partial basement) ±68,445 SF gross mixed-use building. 105-room hotel, with 1st floor restaurant; Type-IA/IIIA; Occ. R-1/A-2. Requires lot merger and demolition of existing structures. DEFERRED ITEMS, FIRE SPRINKLERS, FIRE ALARM, GREASE HOOD SUPPRESSION, STANDPIPE SYSTEM, STOREFRONT SYSTEM,OPERABLE PARTITION, CONTINUOUS ROD HOLDDOWN SYSTEM, AND ELEVATORS DEFERRED. - PLNG-INSP. Two DEMO permit were issued COM-1807391 / COM-1807394 REVISON COM-2021448-ELECTRICAL TO KITCHEN
Demo Permit
Demolition of a two story building / 6,000 sq. ft.
Fort Sutter Hotel
EPC Submittal - New Commercial Building - New 7 level (6 floors plus partial basement) Hotel. See Project Information for Scope Description. REVISON COM-2021448-A couple additional lights are being added to the kitchen to increase foot candles. Clarification on kitchen power for floor outlet at movable island.
Source: City of Sacramento CDD, Issued Building Permits (Current Year) · Geography: parcel (APN as recorded on the permit) · Source updated Nov 1, 2026 · Retrieved Nov 3, 2026 · The city publishes current status without a date, so status changes are dated by the window between our snapshots.
APN 007-0172-024-0000 · 7 permits matched by address and location
Matched by checking which current parcel holds each permit's mapped point, or carries its street address. This is our inference, not an official County lineage record.
Source: Sacramento County GIS, Parcels · Geography: current parcel polygons · Source updated Nov 8, 2026 · Retrieved Nov 8, 2026
Assessed values and limited building characteristics (Sacramento County Assessor)
Search by parcel number 007-0172-020-0000. Shows direct levies and special assessments.
Search the city's permit system by address or record number
County systems may not return results for a retired number. If so, use a current parcel listed above. Most recent record here: Feb 18, 2020.