Retired / historical parcel number
Recorded at 414 T St; 416 T St; 434 T St and 1 more · Records from 2017–2026
EV CHARGERS
EPC - INSTALL (26) LEVEL-2 EV CHARGING STATIONS ON SEVEN (7) PEDESTALS WITH TWO 32A SWTCH CHARGER HAS DEDICATED 40A CIRCUITS. WE WILL INSTALL (14) WALL MOUNT WITH A SINGLE 32A SWTCH CHARGER HAS DEDICATED 40A CIRCUITS LOCATED ON THE EXTERIOR OF THE PROPERTY. RUN 2" PVC CONDUIT FROM THE (02) 200A EV-DEDICATED PANEL & (01) 150A EV-DEDICATED PANEL TO EACH PEDESTAL LOCATION, USING (26) 40-AMP CIRCUITS WITH #8 THHN COPPER CONDUCTORS (2-WIRE + GROUND) FOR EV CHARGER.
434 T St: (3) HVAC C/O Split System
HVAC Permit: C/O 3 HVAC units: The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Community Center for Complex. ALL WORK SUBJECT TO FIELD INSPECTION.
434 T St: (3) HVAC C/O Split System
C/O 3 HVAC units: The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Community Center for Complex
446 T Street com HVAC permit minor no plans
HVAC Permit: Remove old HVAC system and replace it with new heat pump and air handler, like for like. The new heat pump system will be installed in the same location as the old HVAC system. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314.
416 T Street com HVAC permit minor no plans
HVAC Permit: Remove existing HVAC system and install new heat pump split system, (condenser unit, air handler in the attic.) The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314.
414 T Street com HVAC permit minor no plans
HVAC Permit: Change out 3 ton split unit. Condenser and air handler, like for like. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314.
416 T St (Trudeau)
Install Electric Vehicle Charging station, 50 amp (Workshop, 434 T St)
Source: City of Sacramento CDD, Issued Building Permits (Current Year) · Geography: parcel (APN as recorded on the permit) · Source updated Nov 1, 2026 · Retrieved Nov 3, 2026 · The city publishes current status without a date, so status changes are dated by the window between our snapshots.
APN 009-0113-029-0001 · 1 permit matched by address and location
APN 009-0113-029-0002 · 1 permit matched by address and location
APN 009-0113-029-0011 · 1 permit matched by address and location
Matched by checking which current parcel holds each permit's mapped point, or carries its street address. This is our inference, not an official County lineage record.
Source: Sacramento County GIS, Parcels · Geography: current parcel polygons · Source updated Nov 8, 2026 · Retrieved Nov 8, 2026
Assessed values and limited building characteristics (Sacramento County Assessor)
Search by parcel number 009-0113-029-0000. Shows direct levies and special assessments.
Search the city's permit system by address or record number
County systems may not return results for a retired number. If so, use a current parcel listed above. Most recent record here: May 15, 2026.