Sacramento 95823 · Parkway · APN 050-0020-044-0000 · City of Sacramento
Zoned R-3 in City of Sacramento with likely ministerial ADU eligibility and zero mapped flood, fire, or fault hazard overlaps; benchmark value $416,000 ($366,000–$466,000).
Zone R-3 allows residential use qualifying for ministerial ADU review under state law.
Source: City of Sacramento zoning · CA Gov. Code 66314
Public building records show issued construction/renovation work on this parcel (46 total permits, latest Oct 13, 2025).
Source: City of Sacramento CDD, Issued Building Permits (Current Year) (parcel APN)
about 6% of the lot of the parcel intersects Zone X: 1% annual chance flood, depth under 1 foot. Outside mandatory federal SFHA insurance rules, but check local drainage and finished-floor requirements.
Source: FEMA National Flood Hazard Layer (parcel polygon)
Automated synthesis of indexed municipal, county, state, and federal public records — informational context only, not a formal appraisal, survey, or legal/tax determination.
$416,000
Benchmark range: $366,000 – $466,000
Electrical / panel (COM-2423075): Issued after 2 mo — slower than 90% of electrical / panel permits in City of Sacramento (median 0d, 90th pct 5d, n=11,023).
Source: City of Sacramento CDD, Issued Building Permits (Current Year) (review-time benchmark)
Sale triggers reassessment to 1.00% base + ~0.14% voter debt (~$433/mo). Confirm exact Mello-Roos / CFD special assessments on the county tax bill.
Source: CA Const. Art. XIIIA (Prop 13) · County Tax Collector
Since November 2024 within ½ mile: 1 homes completed, 2 permitted, 1 proposed or in review.
4 projects with a record in this window, grouped by us from permits and State housing reports. Units are as proposed on each project's latest record and counted at its current stage.
344 permits within ½ mile since November 2024
The map shows new construction, ADUs, demolitions, additions, and renovations. Routine systems work (roofs, HVAC, water heaters) is counted but not mapped. Unit counts are as stated on permits.
Source: City of Sacramento CDD, Issued Building Permits (Current Year) · Geography: permits located by parcel, ½ mile radius · Source updated Nov 1, 2026 · Retrieved Nov 3, 2026
Public-records benchmark estimate combining Zillow Home Value Index (Data provided by Zillow), Census ACS 5-year estimates, parcel land-use/lot characteristics, and issued building permits. Not an official appraisal.
No ADU or new-home permits recorded within ¼ mile in this window.
Permit counts, by the date issued (or applied, if not yet issued). Lot splits are planning cases, which we don't have.
We read public zoning and hazard maps against state law (ADUs: Gov. Code 66314; SB 9: Gov. Code 65852.21 and 66411.7). Local rules, title, tenancy history and site conditions can change the answer. Check with City of Sacramento's planning department before relying on it.
Sources: City of Sacramento CDD, Zoning (retrieved Nov 11, 2026) · CAL FIRE Office of the State Fire Marshal, Fire Hazard Severity Zones in the State Responsibility Area (effective 2024-04-01) (retrieved Nov 9, 2026) · CAL FIRE Office of the State Fire Marshal, Fire Hazard Severity Zones in the Local Responsibility Area (map dated 2025-03-24) (retrieved Nov 9, 2026) · FEMA, National Flood Hazard Layer — flood hazard zones (retrieved Nov 9, 2026) · FEMA, National Flood Hazard Layer — FIRM panels (retrieved Nov 9, 2026) · California Geological Survey, Alquist-Priolo Earthquake Fault Zones (retrieved Nov 9, 2026) · Zoning classes: our classification of R-3 as multifamily residential, checked against the zone description on Oct 24, 2026
Chronological history of building permit applications and issuances, snapshot-dated status changes, State housing entitlements, surrounding development within ½ mile, and area home-value trends.
In "In review" for 13 mo (since Oct 28, 2025), with no new permit record in 13 mo. · 1 unit · $204,448 declared valuation
Nearby electrical / panel (4015 Robinridge Way): First appeared in published agency feed
Record RES-2623827 · Detected between snapshots
Source: City of Sacramento CDD, Issued Building Permits (Current Year) · Snapshot diff within ½ mile
Nearby electrical / panel (108 Creekside Cir): First appeared in published agency feed
Record RES-2622367 · Detected between snapshots
Source: City of Sacramento CDD, Issued Building Permits (Current Year) · Snapshot diff within ½ mile
Nearby addition (adds square footage) (7619 Bluebrook Way): Status changed from Applied to Plan Check Wait
Record RES-2621227 · Detected between snapshots
Source: City of Sacramento CDD, Issued Building Permits (Current Year) · Snapshot diff within ½ mile
Nearby roof replacement (7653 Franklin Blvd): First appeared in published agency feed
Record RES-2623431 · Detected between snapshots
Source: City of Sacramento CDD, Issued Building Permits (Current Year) · Snapshot diff within ½ mile
Nearby hvac / heat pump (7580 Bluebrook Way): First appeared in published agency feed
Record RES-2622705 · Detected between snapshots
Source: City of Sacramento CDD, Issued Building Permits (Current Year) · Snapshot diff within ½ mile
Nearby hvac / heat pump (4201 Brookfield Dr): Status changed from Issued to Expired Permit
Record COM-2521238 · Detected between snapshots
Source: City of Sacramento CDD, Issued Building Permits (Current Year) · Snapshot diff within ½ mile
Nearby hvac / heat pump (4534 Cedarwood Way): Status changed from Issued to Finaled
Record RES-2616550 · Detected between snapshots
Source: City of Sacramento CDD, Issued Building Permits (Current Year) · Snapshot diff within ½ mile
Nearby general repair (4211 Weymouth Ln): Status changed from Issued to Finaled
Record COM-2606353 · Detected between snapshots
Source: City of Sacramento CDD, Issued Building Permits (Current Year) · Snapshot diff within ½ mile
Nearby electrical / panel (4015 Robinridge Way): First appeared in published agency feed
Record RES-2623373 · Detected between snapshots
Source: City of Sacramento CDD, Issued Building Permits (Current Year) · Snapshot diff within ½ mile
Nearby roof replacement (173 Cedar Rock Cir): Status changed from Issued to Finaled
Record RES-2619185 · Detected between snapshots
Source: City of Sacramento CDD, Issued Building Permits (Current Year) · Snapshot diff within ½ mile
Nearby roof replacement (4601 Brookfield Dr): Status changed from Issued to Finaled
Record RES-2620326 · Detected between snapshots
Source: City of Sacramento CDD, Issued Building Permits (Current Year) · Snapshot diff within ½ mile
Nearby windows / doors / siding (1 Fuchsia Ct): Status changed from Issued to Finaled
Record RES-2618709 · Detected between snapshots
Source: City of Sacramento CDD, Issued Building Permits (Current Year) · Snapshot diff within ½ mile
Nearby repair tied to a housing/code case (155 Cedar Rock Cir): Status changed from Issued to Finaled
Record RES-2610214 · Detected between snapshots
Source: City of Sacramento CDD, Issued Building Permits (Current Year) · Snapshot diff within ½ mile
Nearby roof replacement (7571 Bluebrook Way): Status changed from Issued to Finaled
Record RES-2620430 · Detected between snapshots
Source: City of Sacramento CDD, Issued Building Permits (Current Year) · Snapshot diff within ½ mile
Nearby ev charger (4223 Brookfield Dr): Status changed from Issued to Finaled
Record COM-2616305 · Detected between snapshots
Source: City of Sacramento CDD, Issued Building Permits (Current Year) · Snapshot diff within ½ mile
Cross-referenced intelligence from our historical development graph—connecting parcels, permits, entity-resolved builders, empirical review-time distributions, and neighborhood renovation trends.
Explore full City of Sacramento development graph →Issued after 2 mo — slower than 90% of electrical / panel permits in City of Sacramento (median 0d, 90th pct 5d, n=11,023).
Issued after 2 mo — slower than 90% of electrical / panel permits in City of Sacramento (median 0d, 90th pct 5d, n=11,023).
Issued after 2 mo — slower than 90% of electrical / panel permits in City of Sacramento (median 0d, 90th pct 5d, n=11,023).
Issued after 2 mo — slower than 90% of electrical / panel permits in City of Sacramento (median 0d, 90th pct 5d, n=11,023).
Issued after 2 mo — slower than 90% of electrical / panel permits in City of Sacramento (median 0d, 90th pct 5d, n=11,023).
Issued after 2 mo — slower than 90% of electrical / panel permits in City of Sacramento (median 0d, 90th pct 5d, n=11,023).
Substantial improvements (additions, interior remodels, ADUs, commercial TI, and new builds) across 4,018 parcels
−18.9% YoY
City baseline: 30.4 / 1k
67 in trailing 24m
Includes 12 ADUs
| Builder / contractor | Primary specialty | Here / ½ mi | ½ mi valuation | Citywide 24m trend |
|---|---|---|---|---|
| Affordable Heating And Air | HVAC / heat pump | 28 on parcel28 in ½ mi | $183,631 | 1 vs 1 prior |
| Guzman Electrical Services | Electrical / panel | 9 on parcel9 in ½ mi | $267,400 | 0 vs 0 prior |
| Prietos Roof Removal | Roof replacement | 8 on parcel8 in ½ mi | $229,650 |
| Permit category | Sample (n) | 25th pct | Median (50th) | 75th pct | 90th pct | Recent 24m median |
|---|---|---|---|---|---|---|
| New single-family home | 3,657 | 28d | 45d | 85d | 184d | 41d(vs 51d prior) |
| New duplex / half-plex | 115 | 82d | 184d | 416d | 575d | 144d(vs 361d prior) |
| New multifamily / condos / mixed-use | 199 | 125d | 210d | 365d | 627d | 199d(vs 289d prior) |
| Accessory dwelling unit (new or conversion) |
HUD Small Area Fair Market Rent · ZIP 95823
HUD FY 2026 · 40th-percentile gross rentCensus ACS 5-year median gross rent (all bedroom counts combined):
Area home-value benchmarks (not an appraisal)
ZIP & neighborhood mediansUnder California Proposition 13, the seller's historical assessed value does not carry over to a buyer. On sale, the parcel is reassessed at the purchase price: 1.00% base rate ($4,150/yr) + local voter-approved bond debt ($581/yr) + fixed direct levies/Mello-Roos ($450/yr).
Insurance & hazard context:
Model adding a backyard ADU or garage conversion under California's Prop 13 blended new-construction assessment (existing house & land tax base stays intact; only ADU build cost is assessed) and SB 13 impact-fee rules.
−$13,999/yr
Cash needed: $91,300
NOI: $11,183/yr
P&I: $2,098/mo
For $0/mo net cash flow
At $1,975/mo gross rent
| Scenario | Assumptions | Year 1 Rent | Year 1 Cash Flow | Cash-on-Cash | Break-Even Rent | Year 5 Cash Flow |
|---|---|---|---|---|---|---|
| Conservative | −8% starting rent, +3% vacancy, +3% combined maintenance/CapEx, 1.5%/yr rent growth | $1,817/mo | −$1,394/mo | -18.3% | $3,762/mo | −$1,363/mo |
| Base (your inputs) | Your entered assumptions, 3.0%/yr rent growth | $1,975/mo | −$1,167/mo | -15.3% | $3,482/mo | −$1,024/mo |
| Optimistic (cap-limited) | +6% starting rent, 3% vacancy, 4.5%/yr rent growth (capped by local ordinance ceiling of 8.6%/yr) | $2,094/mo | −$1,036/mo | -13.6% | $3,401/mo | −$766/mo |
Rental regulatory context (informational only — not legal advice):
California AB 1482 (Tenant Protection Act, Civ. Code § 1947.12) caps annual rent increases at 5% + local CPI (max 10%) on covered properties. In City of Sacramento: Sacramento Tenant Protection Program (City Code Ch. 5.156) — 5% + CPI (8.6% cap effective July 1, 2026) for covered pre-1995 multifamily units. Official program rules ↗
E-Permit: Tear Off - Yes, Resheet - No, 1 layer(s), 22 squares of TPO Single Ply. CRRC: 0676-0001
E-Permit: Tear Off - Yes, Resheet - No, 1 layer(s), 22 squares of TPO Single Ply. CRRC: 0676-0001
COMM POOL REPLASTER
REMOVE OLD PLASTER AND REAPPLY 2 COATS OF NEW PLASTER. Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994, are exempt). Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. ALL WORK SUBJECT TO FIELD INSPECTION.
E-Permit: Tear Off - Yes, Resheet - Yes, 1 layer(s), 41 squares of TPO Single Ply. CRRC: 0676-0001
E-Permit: Tear Off - Yes, Resheet - Yes, 1 layer(s), 56 squares of PVC Single Ply. CRRC: 0676-0001
ELECTRICAL - 8 SHARED PLANS
EPC - 8 shared plans -- c/o 16 unit meters like for like and house meter, main feed conduit and wire to be replaced. Shared plans reviewed under COM-2423054
ELECTRICAL - 8 SHARED PLANS
EPC - 8 shared plans -- c/o 16 unit meters like for like and house meter, main feed conduit and wire to be replaced. Shared plans reviewed under COM-2423054
ELECTRICAL - 8 SHARED PLANS
EPC - 8 shared plans -- c/o 16 unit meters like for like and house meter, main feed conduit and wire to be replaced. Shared plans reviewed under COM-2423054
ELECTRICAL - 8 SHARED PLANS
EPC - 8 shared plans -- c/o 16 unit meters like for like and house meter, main feed conduit and wire to be replaced. Shared plans reviewed under COM-2423054
ELECTRICAL - 8 SHARED PLANS
EPC - 8 shared plans -- c/o 16 unit meters like for like and house meter, main feed conduit and wire to be replaced. Shared plans reviewed under COM-2423054
ELECTRICAL - 8 SHARED PLANS
EPC - 8 shared plans -- c/o 16 unit meters like for like and house meter, main feed conduit and wire to be replaced. Shared plans reviewed under COM-2423054
ELECTRICAL - 8 SHARED PLANS
EPC - 8 shared plans -- c/o 16 unit meters like for like and house meter, main feed conduit and wire to be replaced. Shared plans reviewed under COM-2423054
ELECTRICAL - 8 SHARED PLANS
EPC - 8 shared plans -- c/o 16 unit meters like for like and house meter, main feed conduit and wire to be replaced. Shared plans reviewed under COM-2423054
E-Permit: Tear Off - Yes, Resheet - No, 1 layer(s), 45 squares of TPO Single Ply. CRRC: 0676-0135
Source: City of Sacramento CDD, Issued Building Permits (Current Year) · Geography: parcel (APN) · Source updated Nov 1, 2026 · Retrieved Nov 3, 2026 · Applied and issued dates come from the city's Applied and Issued permit datasets. The city publishes current status without a date, so status changes are dated by the window between our snapshots.
No housing activity reported to the State for this parcel (2018–2025 reports).
Source: California HCD, Housing Element Annual Progress Report — Table A2 · Geography: project (parcel) · Retrieved Nov 9, 2026 · From City of Sacramento's Housing Element Annual Progress Reports. A project can appear in several report years as it moves from entitlement to permit to completion.
Source: City of Sacramento CDD, Zoning · Geography: zoning district polygon at parcel point · Source updated Nov 11, 2026 · Retrieved Nov 11, 2026
4.93 acres
Assessor's classification for assessment purposes. This is not zoning.
4505 BROOKFIELD DR; 4505 BROOKFIELD DR # 1 # 1; 4505 BROOKFIELD DR # 2 # 2
Source: Sacramento County GIS, Parcels · Geography: parcel · Source updated Nov 8, 2026 · Retrieved Nov 8, 2026
Assessed values and limited building characteristics (Sacramento County Assessor)
Current roll value. This is assessed value, not market value.
Search by parcel number 050-0020-044-0000. Shows direct levies and special assessments.
Search the city's permit system by address or record number
The official flood hazard map for this location. Our reading of it is under What could be built here.
This site does not show owner names.
| Builder Arts Design | Pool / spa | 1 on parcel1 in ½ mi | $11,750 | 0 vs 0 prior |
| The Gb Group Recent nearby: 87 Creeks Edge Way (Jan 17, 2023) | Addition (adds square footage) | 10 in ½ mi | $320,000 | 0 vs 7 prior |
| F And T Investments Recent nearby: 4159 Brookfield Dr (Mar 27, 2026) | Remodel / interior alteration | 5 in ½ mi | $437,700 | 13 vs 11 prior+18% |
| Yancey Recent nearby: 4672 Kerwood Way (Feb 12, 2024) | Remodel / interior alteration | 3 in ½ mi | $94,410 | 38 vs 46 prior−17% |
| Kft Construction Recent nearby: 4359 Shining Star Dr 2 (May 19, 2021) | Remodel / interior alteration | 3 in ½ mi | $82,500 | 0 vs 0 prior |
| Jackson Properties Recent nearby: 7584 Center Pkwy (Jul 10, 2020) | Commercial tenant improvement | 2 in ½ mi | $694,623 | 12 vs 23 prior−48% |
| Pacific Builders Recent nearby: 280 Stone Valley Cir (Jun 27, 2022) | Addition (adds square footage) | 2 in ½ mi | $32,000 | 12 vs 26 prior−54% |
| 1,693 |
| 57d |
| 97d |
| 172d |
| 284d |
| 97d(vs 103d prior) |
| Addition (adds square footage) | 1,948 | 6d | 42d | 83d | 162d | 49d(vs 43d prior) |
| Remodel / interior alteration | 8,151 | 1d | 4d | 21d | 55d | 5d |
| Commercial tenant improvement | 2,366 | 30d | 63d | 119d | 201d | 61d(vs 64d prior) |
| Pool / spaOn this parcel | 1,059 | 1d | 5d | 25d | 49d | 4d(vs 7d prior) |
Source: City of Sacramento CDD, Issued Building Permits (Current Year) · Computed from issued permits with recorded application and issuance dates over the trailing 60 months. Categories with fewer than 20 permits are excluded.
REROOF
E-Permit: Tear Off - Yes, Resheet - No, 1 layer(s), 29 squares of TPO Single Ply. CRRC: 0676-0135
E-Permit: Tear Off - Yes, Resheet - No, 1 layer(s), 29 squares of PVC Single Ply. CRRC: 0676-0135
E-Permit: Tear Off - Yes, Resheet - No, 2 layer(s), 50 squares of TPO Single Ply. CRRC: 0610-0017
7543 Franklin Blvd. com electrical minor no plans
Electrical Permit: Replace the exiting electrical main services to 7 building like for like. The exiting services are Zinsco panels and insurance company is asking to replace them. 5-600A 1 ph with 17- 100A meters and 3-300A 1 ph with 6 -100A meter. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314.
HVAC C/O
Unit #12- Like for like change out of a 14 seer, 2 ton gas/electric package system located on roof. No duct work.The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314.
HVAC C/O
Unit #7- Like for like change out of a 14 SEER, 2 TON Gas/Electric Split System on Roof and in Closet. 24k BTU. No Duct Work.
HVAC C/O
Unit #14- Like for like change out of a 14 SEER, 2 TON GAS/ELECTRIC package system located on roof. No DUCT WORK. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314.
C/O (2) HVAC Roof-Mount Package systems (UNITS 10 & 11)
Change-out existing HVAC placed in the same location. The appliance/s shall not exceed the size of the existing units by more than 25%. New or relocated units shall be screened from street views by the building with no portion of the new unit being visible from any street views. HERS Report required at final inspection. Smoke & Carbon Monoxide Alarms required per CRC sections R314 & R315. Access to perform inspection/s must be provided by the Party requesting the inspection.
C/O HVAC Package system (UNIT # 10)
UNIT # 10 - LIKE FOR LIKE CHANGE OUT OF A 2 TON, 14 SEER GAS / ELECTRIC PACKAGE SYSTEM LOCATED ON ROOFTOP. 40K BTU NO DUCT WORK.
C/O HVAC Package system (UNIT # 3)
UNIT # 3 - C/O LIKE FOR LIKE CHANGE OUT OF A 2 TON, 14 SEER GAS / ELECTRIC PACKAGE SYSTEM LOCATED ON ROOFTOP. 40K BTU NO DUCT WORK.
C/O HVAC Package system (UNIT # 2)
UNIT # 2 - C/O LIKE FOR LIKE CHANGE OUT OF A 2 TON, 14 SEER GAS / ELECTRIC PACKAGE SYSTEM LOCATED ON ROOFTOP. 40K BTU NO DUCT WORK.
C/O HVAC Package system (UNIT 1)
UNIT 1 - C/O existing roof-mount package system - No duct work. HERS report required at final. Smoke & Carbon Monoxide Alarms required per CRC sections R314 & R315. Access to perform inspection/s must be provided by the Party requesting the inspection.
UNIT 6, C/O HVAC
UNIT 6, C/O HVAC GAS/ELECTRIC 2 TON PACKAGE UNIT, NO DUCTING The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314
UNIT 16, C/O HVAC
UNIT 16, C/O HVAC GAS/ELECTRIC 2 TON PACKAGE UNIT. NO DUCTING The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314
HVAC-Package Unit
Change out Package unit HVAC unit like for like. No duct work to be completed with this permit.
HVAC-Package Unit
Change out Package unit HVAC unit like for like. No duct work to be completed with this permit.
HVAC-Package unit
Change out 2 ton package unit, roof top mount. No duct work to be completed with this permit. Like for like size.
C/O HVAC
Unit 4***2 ton rooftop change out. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314.
C/O HVAC
Unit 1***2 ton rooftop change out. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314.
C/O 2 TON RTU
C/O 2 TON PACKAGED RTU LIKE FOR LIKE. HVAC change out. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314.
C/O 2 TON RTU
C/O 2 TON PACKAGED RTU LIKE FOR LIKE. HVAC change out. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314.
C/O 2 TON RTU
C/O 2 TON PACKAGED RTU LIKE FOR LIKE. HVAC change out. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314.
C/O 2 TON RTU
C/O 2 TON PACKAGED RTU LIKE FOR LIKE. HVAC change out. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314.
C/O HVAC
C/O 2 TON PACKAGED RTU LIKE FOR LIKE. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314
7533 Franklin Blvd- Unit #4 2 Ton / 40BTU Roof Pkg C/O
7533 Franklin Blvd- Unit #4 2 Ton / 40BTU Roof Pkg C/O. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314
7543 Franklin Blvd Unit # 2 - 40K BTU / 2 Ton Roof Pak C/O
7543 Franklin Blvd Unit # 2 - 40K BTU / 2 Ton Roof Pak C/O Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314
HVAC CHANGE OUT
CHANGE OUT TWO TON ROOF MOUNT PACKAGE UNIT, 40K BTU
HVAC CHANGE OUT
BLDG #4507, UNIT #10; HVAC PACKAGE UNIT CHANGE OUT (LIKE FOR LIKE) The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314.
UNIT 16-SOUTHGATE TOWN / TERRACE HOMES INC / HVAC CO
UNIT 16: The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25. . CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314
HVAC Change Out
HVAC change out. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%.
hvac c/o # 11
HVAC change out of existing roof mount package unit like for like. . The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314
hvac c/o #16
HVAC change out of existing roof mount package unit like for like. . The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314