Active in City of Sacramento (78 permits)
Raw permit filing aliases merged: BROWN'S HEATING & AIR · BROWN'S HEATING AND AIR INC
77 issued · 42 parcels
vs 27 prior 24m(+30%)
0 construction/remodel
Sum of permit job values
Application → issuance
Latest: Oct 19, 2026
Where this builder's geocoded permits cluster
Compares this builder's median days from permit application to issuance against all peer permits in City of Sacramento (trailing 5-year benchmark).
| Permit Category | Permits | Issued | Units | Declared Valuation | Builder Median Review | City Median (75th pct) | Relative Pace |
|---|---|---|---|---|---|---|---|
| 55 | 55 | — | $625,931 | 0d (n=55) | 0d (0d p75) | Within typical range | |
| 16 | 15 | — | $146,080 | 0d (n=15) | 0d (0d p75) | Within typical range | |
| 7 | 7 | — | $31,220 | 0d (n=7) | 0d (0d p75) | Within typical range |
Click any address to open the full property dossier or inspect the official agency record
| Property / Parcel | Record & Category | Applied / Issued | Status | Valuation | Work Description & Raw Attribution |
|---|---|---|---|---|---|
| 6501 Elder Creek Rd 46 City of Sacramento · APN 038-0210-062-0000 | HVAC / heat pump COM-2623192Portal ↗ | Issued Oct 19, 2026 3d review | Issued | $11,945 | LIKE FOR LIKE 3 TON, 14.3 SEER3, R454B, 80% AFUE, GAS SPLIT HVAC SYSTEM CHANGE OUT WITH OUTDOOR CONDENSER LOCATED ON THE GROUND. NO DUCT WORK PERMITTED. THE EXISTING UNIT SHALL BE REMOVED. THE NEW UNIT SHALL BE PLACED IN THE SAME LOCATION AS THE EXISTING UNIT. AS NOTED ON FORM CDD-0036, APPLIANCES HEAVIER THAN 400LBS REQUIRE ENGINEERING CALCULATIONS. CF1R-ALT-02-E ON FILE. CARBON MONOXIDE & SMOKE ALARMS REQUIRED. REFERENCE CRC SECTIONS R310.1 & R311.1. ALL WORK IS SUBJECT TO FIELD INSPECTION. Filed as: BROWN'S HEATING AND AIR INC |
| 7971 Rush River Dr City of Sacramento · APN 031-1030-019-0000 | HVAC / heat pump COM-2623012Portal ↗ | Issued Oct 16, 2026 2d review | Issued | $7,600 | HVAC Permit: FOR #20- Like for like 2 ton, 14.3 SEER2, R41a, hydronic, split HVAC system change out with outdoor condenser located on the ground. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R310.1 & R311.1. Filed as: BROWN'S HEATING AND AIR INC |
| 2316 Capitol Ave 1 City of Sacramento · APN 007-0156-005-0000 | HVAC / heat pump COM-2617735Portal ↗ | Issued Aug 19, 2026 6d review | Issued | $8,460 | LIKE FOR LIKE 2 TON, 14.3 SEER2,R454B, HEAT PUMP, SPLIT HVAC SYSTEM CHANGE OUT, WITH THE OUTFOOR CONDENSER LOCATED ON THE GROUND AND THE INDOOR AIR HANDLER LOCATED IN A CLOSET. NO DUCT WORK PERMITTED.CF-1R-ALT-HVAC ON FILE.THE EXISTING UNIT SHALL BE REMOVED. THE NEW UNIT SHALL BE PLACED IN THE SAME LOCATION AS THE EXISTING UNIT. CARBON MONOXIDE & SMOKE ALARMS ARE REQUIRED. REFERENCE CRC SECTIONS R315 & R314. ALL WORK IS SUBJECT TO FIELD INSPECTION. Filed as: BROWN'S HEATING AND AIR INC |
| 6501 Elder Creek Rd 54 City of Sacramento · APN 038-0210-062-0000 | HVAC / heat pump COM-2616669Portal ↗ | Issued Aug 5, 2026 2d review | Finaled | $8,375 | LIKE FOR LIKE 2 TON, 14.3 SEER2, R454B, 4OK BTU, 80% AFUE, GAS, HVAC SYSTEM WITH OUTDOOR CONDENSER LOCATED ON THE GROUND AND INDOOR FURNACE LOCATED IN CLOSET.NO DUCT WORK PERMITTED. CF-1R-ALT-HVAC ON FILE.THE EXISTING UNIT SHALL BE REMOVED. THE NEW UNIT SHALL BE PLACED IN THE SAME LOCATION AS THE EXISTING UNIT.AS NOTED ON FORM CDD-0036, APPLIANCES HEAVIER THAN 400LBS REQUIRE ENGINEERING CALCULATIONS.CARBON MONOXIDE & SMOKE ALARMS ARE REQUIRED. REFERENCE CRC SECTIONS R315 & R314. ALL WORK IS SUBJECT TO FIELD INSPECTION. Filed as: BROWN'S HEATING AND AIR INC |
| 6501 Elder Creek Rd 26 City of Sacramento · APN 038-0210-062-0000 | HVAC / heat pump COM-2616403Portal ↗ | Issued Jul 31, 2026 1d review | Finaled | $8,375 | HVAC Permit: FOR UNIT 26-Like for like 2 ton, 14.3 SEER2, R454b, 40K BTUs, 80% AFUE, gas , HVAC system with outdoor condenser located on the ground and indoor furnace located in the closet. Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994, are exempt). Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: BROWN'S HEATING AND AIR INC |
| 6501 Elder Creek Rd 96 City of Sacramento · APN 038-0210-062-0000 | HVAC / heat pump COM-2616401Portal ↗ | Issued Jul 31, 2026 1d review | Finaled | $8,375 | LIKE FOR LIKE 2 TON GAS HVAC SYSTEM WITH OUTDOOR CONDENSER LOCATED ON THE GROUND AND INDOOR FURNACE IN CLOSET. CARBON MONOXIDE & SMOKE ALARMS ARE REQUIRED. REFERENCE CRC SECTIONS R315 & R314. Filed as: BROWN'S HEATING AND AIR INC |
| 7627 Windbridge Dr City of Sacramento · APN 031-1170-013-0000 | HVAC / heat pump COM-2614545Portal ↗ | Issued Jul 9, 2026 0d review | Issued | $7,215 | HVAC Permit: FOR #55-Like for like 1.5 ton, 14.3 SEER2, R454b, 80% AFUE, gas split HVAC system change out with outdoor condenser located on the ground. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: BROWN'S HEATING AND AIR INC |
| 8200 Bruceville Rd 111 City of Sacramento · APN 117-0184-004-0000 | HVAC / heat pump COM-2614490Portal ↗ | Issued Jul 9, 2026 1d review | Finaled | $8,335 | HVAC Permit: FOR UNIT 111- Like for like 1 ton, WSHP Horizontal, 14.3 SEER2, hydronic water source heat pump, HVAC aid handler, located in the ceiling. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: BROWN'S HEATING AND AIR INC |
| 2536 Wah Ave City of Sacramento · APN 041-0034-016-0000 | Roof replacement COM-2613299Portal ↗ | Issued Jun 26, 2026 2d review | Issued | $10,195 | HVAC Permit: Like for like 3 ton, 14.3 SEER2, 80% AFUE, gas package unit located on the roof. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: BROWN'S HEATING AND AIR INC |
| 8200 Bruceville Rd City of Sacramento · APN 117-0184-004-0000 | HVAC / heat pump COM-2610922Portal ↗ | Issued Jun 25, 2026 29d review | Issued | $26,595 | HVAC Permit: Like for like ceiling mounted 1 ton, 14.3 SEER2, Hydronic WSHP horizontal packaged HVAC unit change out (3x) The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: BROWN'S HEATING AND AIR INC |
| 8200 Bruceville Rd City of Sacramento · APN 117-0184-004-0000 | HVAC / heat pump COM-2612919Portal ↗ | Issued Jun 24, 2026 6d review | Issued | $8,865 | LIKE FOR LIKE CEILING MOUNTED 1 TON 14.3 SEER2, R454B HYDRONIC WSHP HORIZONTAL PACKAGED HVAC UNIT CHANGE OUT. THE EXISTING UNITS SHALL BE REMOVED. THE NEW UNITS SHALL BE PLACED IN THE SAME LOCATION AS THE EXISTING UNITS. AS NOTED ON FORM CDD-0036, APPLIANCES HEAVIER THAN 400LBS REQUIRE ENGINEERING CALCULATIONS. CARBON MONOXIDE & SMOKE ALARMS ARE REQUIRED. REFERENCE CRC SECTIONS R315 & R314. ALL WORK IS SUBJECT TO FIELD INSPECTION. Filed as: BROWN'S HEATING AND AIR INC |
| 4000 Alan Shepard St 268 City of Sacramento · APN 225-2300-002-0000 | HVAC / heat pump COM-2611791Portal ↗ | Issued Jun 15, 2026 7d review | Issued | $6,995 | HVAC LIKE FOR LIKE CHANGE OUT. AI HANDLER MOUNTED IN CEILING. OUTDOOR CONDENSER LOCATED ON GROUND. NO DUCT WORK PERMITTED. CF-1R-ALT-HVAC ON FILE. CF1R REQUIRED AT FINAL INSPECTION. THE EXISTING UNIT SHALL BE REMOVED. THE NEW UNIT SHALL BE PLACED IN THE SAME LOCATION AS THE EXISTING UNIT. AS NOTED ON FORM CDD-0036, APPLIANCES HEAVIER THAN 400LBS REQUIRE ENGINEERING CALCULATIONS. CARBON MONOXIDE & SMOKE ALARMS ARE REQUIRED. REFERENCE CRC SECTIONS R315 & R314. ALL WORK IS SUBJECT TO FIELD INSPECTION. Filed as: BROWN'S HEATING AND AIR INC |
| 8200 Bruceville Rd City of Sacramento · APN 117-0184-004-0000 | HVAC / heat pump COM-2610968Portal ↗ | Issued Jun 1, 2026 4d review | Issued | $35,460 | LIKE FOR LIKE CEILING MOUNTED 1 TON, 14.3 SEER2, R454B HYDRONIC WSHP HORIZONTAL PACKAGED HVAC UNIT CHANGE OUT (X4). THE EXISTING UNITS SHALL BE REMOVED. THE NEW UNITS SHALL BE PLACED IN THE SAME LOCATION AS THE EXISTING UNITS. AS NOTED ON FORM CDD-0036, APPLIANCES HEAVIER THAN 400LBS REQUIRE ENGINEERING CALCULATIONS. CARBON MONOXIDE & SMOKE ALARMS ARE REQUIRED. REFERENCE CRC SECTIONS R315 & R314. ALL WORK IS SUBJECT TO FIELD INSPECTION. Filed as: BROWN'S HEATING AND AIR INC |
| 3409 J St 1 City of Sacramento · APN 007-0062-024-0000 | HVAC / heat pump COM-2610954Portal ↗ | Issued May 29, 2026 1d review | Finaled | $9,400 | HVAC Permit: Like for like closet mounted 3 ton, 14.3 SEER2, R45b, 80% AFUE, gas split HVAC system with outdoor condenser change out. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: BROWN'S HEATING AND AIR INC |
| 8200 Bruceville Rd City of Sacramento · APN 117-0184-004-0000 | HVAC / heat pump COM-2610918Portal ↗ | Issued May 29, 2026 2d review | Issued | $8,865 | HVAC Permit: Like for like ceiling mounted 1 ton, 14.3 SEER2, R454b hydronic WSHP horizontal packaged HVAC unit change out. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: BROWN'S HEATING AND AIR INC |
| 3531 Tice Creek Way City of Sacramento · APN 225-2230-017-0000 | HVAC / heat pump RES-2610681Portal ↗ | Issued May 26, 2026 0d review | Finaled | $11,145 | No Duct Work Permitted. Change-out Split System to Ground Mount. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. Filed as: BROWN'S HEATING AND AIR INC |
| 8200 Bruceville Rd City of Sacramento · APN 117-0184-004-0000 | Plumbing / water heater / sewer COM-2610549Portal ↗ | Issued May 26, 2026 4d review | Issued | $15,075 | Change-out installation of Gas - 100 gallon to Gas - 100 gallon, located inside building, screening not required. Filed as: BROWN'S HEATING AND AIR INC |
| 2101 Zurlo Way City of Sacramento · APN 201-0540-028-0000 | HVAC / heat pump COM-2605041Portal ↗ | Issued May 8, 2026 56d review | Issued | $8,200 | HVAC Permit: Like or like HVAC change out-1.5 tons, 14.3 SEER2, hydronic HVAC split system, furnace mounted in ceiling. Outdoor condenser located on the ground. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: BROWN'S HEATING AND AIR INC |
| 1213 42nd Ave City of Sacramento · APN 024-0222-022-0000 | HVAC / heat pump RES-2608173Portal ↗ | Issued Apr 24, 2026 0d review | Finaled | $7,825 | Change-out installation of Electric Heat Pump 80 gallons + to Electric Heat Pump 80 gallons +, relocate to outside building, within Existing Exterior Enclosure. Filed as: BROWN'S HEATING AND AIR INC |
| 1213 42nd Ave City of Sacramento · APN 024-0222-022-0000 | Roof replacement RES-2607741Portal ↗ | Issued Apr 20, 2026 0d review | Finaled | $22,040 | Change-out w/new ducts Roof Mount to Roof Mount. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. Filed as: BROWN'S HEATING AND AIR INC |
| 1616 Q St City of Sacramento · APN 006-0294-018-0000 | HVAC / heat pump COM-2521144Portal ↗ | Issued Apr 2, 2026 177d review | Issued | $91,068 | Like-for-like install of 2ton heat pump package units on the rooftop. There are 12 units total, on 1 rooftop. Per CDD-0036, all 12 units existing weights are 325 lbs and proposed weight is 290 lbs for each unit. As noted on form CDD-0036, appliances heavier than 400lbs require engineering calculations. Provide engineered calculations and specifications for anchorage of new HVAC unit to existing structure per ASCE 7-16 §13.1.4 and §13.6 (e.g., clips/fasteners from new HVAC unit to existing curb/structure). All work subject to field inspection. Filed as: BROWN'S HEATING AND AIR INC |
| 2133 Harris Ave City of Sacramento · APN 252-0031-033-0000 | Roof replacement RES-2604087Portal ↗ | Issued Mar 2, 2026 0d review | Issued | $12,655 | No Duct Work Permitted. Change-out Roof Mount to Roof Mount (all-electric heat pump). The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. Filed as: BROWN'S HEATING AND AIR INC |
| 2310 Capitol Ave 14 City of Sacramento · APN 007-0156-025-0000 | HVAC / heat pump COM-2522987Portal ↗ | Issued Jan 28, 2026 86d review | Issued | $8,100 | HVAC like for like change-out 2 ton The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: BROWN'S HEATING AND AIR INC |
| 4000 Alan Shepard St 208 City of Sacramento · APN 225-2300-002-0000 | HVAC / heat pump COM-2519545Portal ↗ | Issued Jan 20, 2026 126d review | Issued | $6,995 | "HVAC Like for Like Change Out: 2 ton, 14.3 SEER2, R-410A, Hydronic, Split System (Ceiling Mount)" As noted on form CDD-0036, appliances heavier than 400lbs require engineering calculations. Provide engineered calculations and specifications for anchorage of new HVAC unit to existing structure per ASCE 7-16 §13.1.4 and §13.6 (e.g., clips/fasteners from new HVAC unit to existing curb/structure). All work subject to field inspection. Filed as: BROWN'S HEATING AND AIR INC |
| 7627 Windbridge Dr City of Sacramento · APN 031-1170-013-0000 | HVAC / heat pump COM-2510249Portal ↗ | Issued Oct 15, 2025 149d review | Expired Permit | $7,495 | HVAC Permit: FOR UNIT 70-HVAC like for like change out-split system=14 SEER, R-4 10A gas 2 ton system. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: BROWN'S HEATING AND AIR INC |