Active in City of Sacramento (61 permits)
Raw permit filing name: ENERGY SAVING PROS CONSTRUCTION INC
52 issued · 42 parcels
vs 11 prior 24m(−45%)
1 construction/remodel
Sum of permit job values
Application → issuance
Latest: Aug 15, 2025
Where this builder's geocoded permits cluster
Compares this builder's median days from permit application to issuance against all peer permits in City of Sacramento (trailing 5-year benchmark).
| Permit Category | Permits | Issued | Units | Declared Valuation | Builder Median Review | City Median (75th pct) | Relative Pace |
|---|---|---|---|---|---|---|---|
| 22 | 21 | — | $728,320 | 3d (n=21) | 3d (8d p75) | Within typical range | |
| 12 | 12 | — | $164,191 | 0d (n=12) | 0d (0d p75) | Within typical range | |
| 8 | 0 | — | — | — | 41d (93d p75) | — | |
| 7 | 7 | — | $139,845 | 0d (n=7) | 0d (0d p75) | Within typical range | |
| 6 | 6 | — | $38,439 | 0d (n=6) | 0d (0d p75) | Within typical range | |
| 4 | 4 | — | $52,684 | 0d (n=4) | 0d (0d p75) | Within typical range | |
| 1 | 1 | — | $6,125 | — | 4d (21d p75) | — | |
| 1 | 1 | — | $11,000 | — | 40d (91d p75) | — |
Click any address to open the full property dossier or inspect the official agency record
| Property / Parcel | Record & Category | Applied / Issued | Status | Valuation | Work Description & Raw Attribution |
|---|---|---|---|---|---|
| 1741 39th St City of Sacramento · APN 008-0461-017-0000 | Roof replacement RES-2517282Portal ↗ | Issued Aug 15, 2025 0d review | Expired Permit | $28,300 | E-Permit: Tear Off - Yes, Resheet - No, 1 layer(s), 27 squares of 30yr Laminated Dimensional Composition. In-progress inspection required if 10 squares or greater. Filed as: ENERGY SAVING PROS CONSTRUCTION INC |
| 1211 Citrusparke Ave City of Sacramento · APN 225-3050-053-0000 | Plan revision / deferred submittal RES-2511544Portal ↗ | Applied Jun 4, 2025 | Complete | — | REVISION TO RES-2506085 - Changed backup circuit from a 100a to a 60a circuit with a 60a main breaker in the backup sub. Filed as: ENERGY SAVING PROS CONSTRUCTION INC |
| 1211 Citrusparke Ave City of Sacramento · APN 225-3050-053-0000 | Plan revision / deferred submittal RES-2509417Portal ↗ | Applied May 8, 2025 | Complete | — | REVISION TO RES-2506085 - Change ESS from (2) Tesla Powerwall 2s to (1) Tesla Powerwall 3 with expansion unit. Filed as: ENERGY SAVING PROS CONSTRUCTION INC |
| 1211 Citrusparke Ave City of Sacramento · APN 225-3050-053-0000 | Solar / battery storage RES-2506085Portal ↗ | Issued Apr 3, 2025 7d review | Finaled | $41,850 | 4.1kw Solar PV System, and nullgal Solar WH System (water heater installed null) W/ESS. All supply side connections, main breaker change-out, and/or panel upgrade will require a second inspection. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314, Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994 are exempt). ALL WORK SUBJECT TO FIELD INSPECTION. REVISION RES-2509417 - Change ESS from (2) Tesla Powerwall 2s to (1) Tesla Powerwall 3 with expansion unit. REVISION RES-2511544 - Changed backup circuit from a 100a to a 60a circuit with a 60a main breaker in the backup sub. Filed as: ENERGY SAVING PROS CONSTRUCTION INC |
| 1671 W El Camino Ave City of Sacramento · APN 225-0450-001-0000 | HVAC / heat pump COM-2426773Portal ↗ | Issued Dec 10, 2024 0d review | Finaled | $7,000 | HVAC Permit: Like for like HVAC replacement. No duct work. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: ENERGY SAVING PROS CONSTRUCTION INC |
| 3991 71st St City of Sacramento · APN 021-0091-019-0000 | HVAC / heat pump RES-2426352Portal ↗ | Issued Dec 4, 2024 0d review | Finaled | $17,000 | Change-out w/new ducts Condenser/Coil Only (Split System) to Condenser/Coil Only (Split System). The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. Filed as: ENERGY SAVING PROS CONSTRUCTION INC |
| 1671 W El Camino Ave City of Sacramento · APN 225-0450-001-0000 | HVAC / heat pump RES-2324696Portal ↗ | Issued Nov 20, 2023 0d review | Expired Permit | $8,790 | No Duct Work Permitted. Change-out Split System to Split System. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. Filed as: ENERGY SAVING PROS CONSTRUCTION INC |
| 191 Menard Cir City of Sacramento · APN 225-1280-057-0000 | Electrical / panel RES-2320436Portal ↗ | Issued Sep 25, 2023 0d review | Finaled | $12,220 | E-Permit: - Underground service, adding 1 outlets (240V), adding 200 Amps subpanel. Filed as: ENERGY SAVING PROS CONSTRUCTION INC |
| 881 Maplegrove Way City of Sacramento · APN 250-0410-143-0000 | HVAC / heat pump RES-2315606Portal ↗ | Issued Jul 26, 2023 0d review | Finaled | $10,500 | No Duct Work Permitted. Change-out Split System to Split System. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. Filed as: ENERGY SAVING PROS CONSTRUCTION INC |
| 191 Menard Cir City of Sacramento · APN 225-1280-057-0000 | HVAC / heat pump RES-2314538Portal ↗ | Issued Jul 13, 2023 0d review | Finaled | $17,850 | No Duct Work Permitted. Change-out Split System to Split System. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. Filed as: ENERGY SAVING PROS CONSTRUCTION INC |
| 191 Menard Cir City of Sacramento · APN 225-1280-057-0000 | Plumbing / water heater / sewer RES-2314534Portal ↗ | Issued Jul 13, 2023 0d review | Finaled | $3,800 | Change-out installation of Gas - 050 gallon to Electric - 052 gallon, located inside building, screening not required. Filed as: ENERGY SAVING PROS CONSTRUCTION INC |
| 3325 55th St City of Sacramento · APN 015-0133-014-0000 | Roof replacement RES-2307571Portal ↗ | Issued Apr 17, 2023 0d review | Finaled | $16,030 | No Duct Work Permitted. New install/New location Mini-Split System. A unit will be installed in a new location. This unit will be fully screened behind a solid fence or alternatively behind shrubs or buildings providing screening resulting in the unit not being visible from any street views. Roof top installations will be located on back roof slopes and below ridge lines, and not visible from street views. Filed as: ENERGY SAVING PROS CONSTRUCTION INC |
| 150 Soaring Hawk Ln City of Sacramento · APN 274-0650-006-0000 | Electrical / panel RES-2306142Portal ↗ | Issued Mar 29, 2023 0d review | Withdrawn | $595 | E-Permit: - Underground service, adding 1 outlets (240V). Filed as: ENERGY SAVING PROS CONSTRUCTION INC |
| 1710 Opper Ave City of Sacramento · APN 017-0201-016-0000 | HVAC / heat pump RES-2304818Portal ↗ | Issued Mar 10, 2023 0d review | Finaled | $1,000 | Change-out w/new ducts N/A to Ducts Only. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. Filed as: ENERGY SAVING PROS CONSTRUCTION INC |
| 2763 12th St City of Sacramento · APN 012-0063-024-0000 | Electrical / panel RES-2300742Portal ↗ | Issued Jan 13, 2023 0d review | Finaled | $3,000 | E-Permit: existing panel 200 Amps - Overhead service, new main panel 200 Amps, Reuse Existing weather head/masthead work. Filed as: ENERGY SAVING PROS CONSTRUCTION INC |
| 2763 12th St City of Sacramento · APN 012-0063-024-0000 | HVAC / heat pump RES-2300623Portal ↗ | Issued Jan 11, 2023 0d review | Finaled | $22,500 | Change-out w/new ducts Mini-Split System to Mini-Split System. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. Filed as: ENERGY SAVING PROS CONSTRUCTION INC |
| 2763 12th St City of Sacramento · APN 012-0063-024-0000 | Plumbing / water heater / sewer RES-2300622Portal ↗ | Issued Jan 11, 2023 0d review | Finaled | $6,700 | Change-out installation of Gas - Tankless to Gas - 050 gallon, located inside building, screening not required. Filed as: ENERGY SAVING PROS CONSTRUCTION INC |
| 7000 Pocket Rd City of Sacramento · APN 031-1090-004-0000 | Solar / battery storage RES-2222354Portal ↗ | Issued Oct 21, 2022 2d review | Finaled | $17,640 | 5.60kw Solar PV System, and 0gal Solar WH System (water heater installed null). All supply side connections, main breaker change-out, and/or panel upgrade will require a second inspection. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314, Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994 are exempt). Filed as: ENERGY SAVING PROS CONSTRUCTION INC |
| 5622 Capstan Way City of Sacramento · APN 024-0101-033-0000 | Electrical / panel RES-2209629Portal ↗ | Issued May 9, 2022 0d review | Finaled | $3,500 | E-Permit: existing panel 100 Amps - Overhead service, new main panel 125 Amps, Replacement weather head/masthead work, main breaker replacement. Filed as: ENERGY SAVING PROS CONSTRUCTION INC |
| 6568 Blanche Dell Dr City of Sacramento · APN 038-0042-010-0000 | Roof replacement RES-2207302Portal ↗ | Issued Apr 6, 2022 0d review | Finaled | $19,295 | E-Permit: Tear Off - Yes, Resheet - No, 1 layer(s), 22 squares of 30yr Laminated Dimensional Composition. In-progress inspection required if 10 squares or greater. Filed as: ENERGY SAVING PROS CONSTRUCTION INC |
| 3471 Larchwood Dr City of Sacramento · APN 250-0404-018-0000 | HVAC / heat pump RES-2206651Portal ↗ | Issued Mar 29, 2022 0d review | Finaled | $9,500 | No Duct Work Permitted. Change-out Split System to Split System. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. Filed as: ENERGY SAVING PROS CONSTRUCTION INC |
| 4164 71st St City of Sacramento · APN 021-0172-070-0000 | Plan revision / deferred submittal RES-2205386Portal ↗ | Applied Mar 11, 2022 | Complete | — | Revision to RES-2200053- decided to not upgrade the main service panel. Revision is to reflect they are going to use the existing panel Filed as: ENERGY SAVING PROS CONSTRUCTION INC |
| 4164 71st St City of Sacramento · APN 021-0172-070-0000 | Plan revision / deferred submittal RES-2200928Portal ↗ | Applied Jan 13, 2022 | Complete | — | REVISION TO RES-2200053- Main Panel Upgrade Filed as: ENERGY SAVING PROS CONSTRUCTION INC |
| 855 Cobble Cove Ln City of Sacramento · APN 031-1240-015-0000 | Solar / battery storage RES-2200525Portal ↗ | Issued Jan 11, 2022 4d review | Finaled | $15,300 | 5.1kw Solar PV System, and 0gal Solar WH System (water heater installed null). All supply side connections, main breaker change-out, and/or panel upgrade will require a second inspection. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314, Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994 are exempt).” Filed as: ENERGY SAVING PROS CONSTRUCTION INC |
| 4164 71st St City of Sacramento · APN 021-0172-070-0000 | Solar / battery storage RES-2200053Portal ↗ | Issued Jan 5, 2022 2d review | Finaled | $23,500 | 8.4kw Solar PV System,All supply side connections, main breaker change-out, and/or panel upgrade will require a second inspection. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314, Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994 are exempt). REVISION RES-2200928 - Main Panel Upgrade SEE REVISION RES-2205386- decided to not upgrade the main service panel. Revision is to reflect they are going to use the existing panel Filed as: ENERGY SAVING PROS CONSTRUCTION INC |