Active in City of Sacramento (22 permits)
Raw permit filing name: KLEEN AIR INC
21 issued · 19 parcels
vs 5 prior 24m
0 construction/remodel
Sum of permit job values
Application → issuance
Latest: Aug 20, 2026
Where this builder's geocoded permits cluster
Compares this builder's median days from permit application to issuance against all peer permits in City of Sacramento (trailing 5-year benchmark).
| Permit Category | Permits | Issued | Units | Declared Valuation | Builder Median Review | City Median (75th pct) | Relative Pace |
|---|---|---|---|---|---|---|---|
| 20 | 19 | 9 | $334,907 | 0d (n=19) | 0d (0d p75) | Within typical range | |
| 2 | 2 | — | $30,008 | 0d (n=2) | 0d (0d p75) | — |
Click any address to open the full property dossier or inspect the official agency record
| Property / Parcel | Record & Category | Applied / Issued | Status | Valuation | Work Description & Raw Attribution |
|---|---|---|---|---|---|
| 2665 Kit Carson St A City of Sacramento · APN 009-0030-040-0000 | HVAC / heat pump COM-2618242Portal ↗ | Issued Aug 20, 2026 0d review | Issued | $14,367 | HVAC c/o like for like split system 2.5 ton 14.5 SEER 96% AFUE 40K BTU NO DUCT WORK PERMITTED. CF-1R-ALT-HVAC ON FILE. CF1R REQUIRED AT FINAL INSPECTION. CARBON MONOXIDE & SMOKE ALARMS ARE REQUIRED. REFERENCE CRC SECTIONS R315 & R314. ALL WORK IS SUBJECT TO FIELD INSPECTION. Filed as: KLEEN AIR INC |
| 2665 Kit Carson St A City of Sacramento · APN 009-0030-040-0000 | HVAC / heat pump COM-2618050Portal ↗ | Applied Aug 18, 2026 | Void | $14,367 | HVAC Permit: FOR UNIT A- HVAC c/o like for like split system 2.5 ton 14.5 SEER 96% AFUE 40K BTU The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: KLEEN AIR INC |
| 8310 Jackson Rd City of Sacramento · APN 079-0310-029-0000 | HVAC / heat pump COM-2617634Portal ↗ | Issued Aug 13, 2026 0d review | Finaled | $7,796 | HVAC Permit: HVAC c/o like for like heat pump mini split system 2 ton 18 SEER 8 HSPF 24K BTUs. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: KLEEN AIR INC |
| 2704 F St City of Sacramento · APN 003-0201-004-0000 | HVAC / heat pump RES-2616254Portal ↗ | Issued Jul 29, 2026 0d review | Finaled | $8,910 | No Duct Work Permitted. Change-out Mini-Split System to Mini-Split System. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. Filed as: KLEEN AIR INC |
| 425 W Silver Eagle Rd 2 City of Sacramento · APN 250-0121-027-0000 | HVAC / heat pump COM-2615170Portal ↗ | Issued Jul 17, 2026 1d review | Issued | $12,823 | HVAC Permit: HVAC c/o like for like split system 2.5 ton 15 SEER 80% AFUE 60K BTU. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: KLEEN AIR INC |
| 190 Dnieper River Way City of Sacramento · APN 225-2540-076-0000 | HVAC / heat pump RES-2614718Portal ↗ | Issued Jul 10, 2026 0d review | Finaled | $6,205 | No Duct Work Permitted. Change-out Condenser/Coil Only (Split System) to Condenser/Coil Only (Split System). The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. Filed as: KLEEN AIR INC |
| 1600 Auburn Blvd City of Sacramento · APN 266-0271-011-0000 | HVAC / heat pump COM-2606776Portal ↗ | Issued Apr 9, 2026 2d review | Issued | $70,873 | HVAC Permit: HVAC c/o like for like (1) heat pump package unit 2.5 ton 14 SEER 8 HSPF 30K BTU, (1) heat pump split system 4 ton 14 SEER 8 HSPF 48K BTU, (1) ductless mini-split system2 ton 14 SEER 8 HSPF 24K BTU, and (1) mini-split system 2 ton 14 SEER 8 HSPF 24K BTU The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: KLEEN AIR INC |
| 5865 Camellia Ave City of Sacramento · APN 005-0202-034-0000 | HVAC / heat pump RES-2605454Portal ↗ | Issued Mar 19, 2026 0d review | Finaled | $14,917 | Change-out w/new ducts Ducts Only to Ducts Only. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. Filed as: KLEEN AIR INC |
| 4500 Beloit Dr City of Sacramento · APN 238-0220-036-0000 | HVAC / heat pump COM-2527584Portal ↗ | Issued Dec 31, 2025 0d review | Issued | $22,144 9 units | HVAC Permit: FOR UNIT D-HVAC change out=heat pump package unit=6 tons, 14 SEER, 8 HSPF, 72K BTUs. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: KLEEN AIR INC |
| 1 Clauss Ct 10c City of Sacramento · APN 022-0280-019-0000 | HVAC / heat pump COM-2524755Portal ↗ | Issued Nov 26, 2025 1d review | Finaled | $6,538 | HVAC Permit: FOR UNIT 16-C: HVAC R-8 duct work only. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: KLEEN AIR INC |
| 28 Creeks Edge Way City of Sacramento · APN 049-0340-046-0000 | HVAC / heat pump RES-2522811Portal ↗ | Issued Oct 31, 2025 1d review | Finaled | $13,002 | HVAC Permit-HVAC split system change out, like for like=2.5 tons, 15 SEER, 80%, AFUE 60Ks BTU. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: KLEEN AIR INC |
| 1517 36th St City of Sacramento · APN 007-0303-013-0000 | HVAC / heat pump RES-2521558Portal ↗ | Issued Oct 14, 2025 0d review | Finaled | $8,910 | No Duct Work Permitted. Change-out Mini-Split System to Mini-Split System. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. Filed as: KLEEN AIR INC |
| 730 50th St City of Sacramento · APN 004-0312-008-0000 | HVAC / heat pump RES-2519364Portal ↗ | Issued Sep 15, 2025 0d review | Finaled | $22,250 | No Duct Work Permitted. Change-out Split System to Split System. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. Filed as: KLEEN AIR INC |
| 4500 Beloit Dr City of Sacramento · APN 238-0220-036-0000 | HVAC / heat pump COM-2513039Portal ↗ | Issued Jun 20, 2025 0d review | Finaled | $22,875 | HVAC Permit-FOR Unit A-HVAC change out-heat pump package unit=7.5 tons, 14 SEER, 80% HSPF, 90K BTUs. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: KLEEN AIR INC |
| 61 Aiken Way City of Sacramento · APN 004-0041-022-0000 | Roof replacement RES-2508470Portal ↗ | Issued Apr 25, 2025 0d review | Finaled | $14,380 | No Duct Work Permitted. Change-out Roof Mount to Roof Mount. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. Filed as: KLEEN AIR INC |
| 5610 34th Ave City of Sacramento · APN 027-0094-005-0000 | Roof replacement RES-2427653Portal ↗ | Issued Dec 20, 2024 0d review | Finaled | $15,628 | No Duct Work Permitted. Change-out Roof Mount to Roof Mount. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. Filed as: KLEEN AIR INC |
| 5370 64th St City of Sacramento · APN 023-0161-007-0000 | HVAC / heat pump RES-2426479Portal ↗ | Issued Dec 5, 2024 0d review | Finaled | $7,823 | No Duct Work Permitted. Change-out Condenser/Coil Only (Split System) to Condenser/Coil Only (Split System). The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. Filed as: KLEEN AIR INC |
| 1536 38th St City of Sacramento · APN 008-0402-008-0000 | HVAC / heat pump RES-2423518Portal ↗ | Issued Oct 25, 2024 0d review | Finaled | $15,866 | No Duct Work Permitted. Change-out Condenser/Coil Only (Split System) to Condenser/Coil Only (Split System). The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. Filed as: KLEEN AIR INC |
| 2831 3rd Ave City of Sacramento · APN 013-0052-024-0000 | HVAC / heat pump RES-2422788Portal ↗ | Issued Oct 16, 2024 0d review | Finaled | $30,420 | HVAC Permit: HVAC change out like for like (2) split systems, (1) 3 ton 15 Seer 80% AFUE 60K BTUs, and 1 2 ton 15 SEER, 80% AFUE 40K BTUs. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: KLEEN AIR INC |
| 1517 36th St City of Sacramento · APN 007-0303-013-0000 | HVAC / heat pump RES-2422249Portal ↗ | Issued Oct 9, 2024 0d review | Expired Permit | $8,910 | No Duct Work Permitted. Change-out Mini-Split System to Mini-Split System. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. Filed as: KLEEN AIR INC |
| 5630 Erskin Fish Way City of Sacramento · APN 201-0580-061-0000 | HVAC / heat pump RES-2416155Portal ↗ | Issued Aug 9, 2024 17d review | Finaled | $18,915 | No Duct Work Permitted. Change-out Split System to Split System. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. Filed as: KLEEN AIR INC |
| 4912 48th St City of Sacramento · APN 022-0064-002-0000 | HVAC / heat pump RES-2323301Portal ↗ | Issued Nov 1, 2023 0d review | Expired Permit | $6,996 | No Duct Work Permitted. Change-out Condenser/Coil Only (Split System) to Condenser/Coil Only (Split System). The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. Filed as: KLEEN AIR INC |