Active in City of Sacramento (7 permits)
Raw permit filing name: M3 MEP LLC
5 issued · 3 parcels
vs 5 prior 24m
0 construction/remodel
Sum of permit job values
Application → issuance
Latest: Nov 8, 2024
Where this builder's geocoded permits cluster
Compares this builder's median days from permit application to issuance against all peer permits in City of Sacramento (trailing 5-year benchmark).
| Permit Category | Permits | Issued | Units | Declared Valuation | Builder Median Review | City Median (75th pct) | Relative Pace |
|---|---|---|---|---|---|---|---|
| 4 | 2 | — | $266,000 | 11d (n=2) | 0d (0d p75) | — | |
| 2 | 2 | — | $4,000 | 14d (n=2) | 14d (29d p75) | — | |
| 1 | 1 | — | $160,000 | — | 10d (61d p75) | — |
Click any address to open the full property dossier or inspect the official agency record
| Property / Parcel | Record & Category | Applied / Issued | Status | Valuation | Work Description & Raw Attribution |
|---|---|---|---|---|---|
| 1100 Richards Blvd City of Sacramento · APN 001-0090-005-0000 | Electrical / panel COM-2424676Portal ↗ | Applied Nov 8, 2024 | Expired Application | $25,000 | 18-005902 EPC - 1. SITE LIGHTING FOR TWO PARKING LOT AREAS. 2. INCLUDES BOTH NEW SITE LIGHTING POLES AND HEADS AND THE REPLACEMENT OF (E) HEADS WITH (N) WHERE THE (E) POLES REMAIN. Filed as: M3 MEP LLC |
| 1100 Richards Blvd City of Sacramento · APN 001-0090-005-0000 | Electrical / panel COM-2424672Portal ↗ | Applied Nov 8, 2024 | Void | $25,000 | EPC - 1. SITE LIGHTING FOR TWO PARKING LOT AREAS. 2. INCLUDES BOTH NEW SITE LIGHTING POLES AND HEADS AND THE REPLACEMENT OF (E) HEADS WITH (N) WHERE THE (E) POLES REMAIN. Filed as: M3 MEP LLC |
| 8655 Younger Creek Dr City of Sacramento · APN 062-0120-032-0000 | Fire alarm / sprinkler COM-2422408Portal ↗ | Issued Oct 25, 2024 14d review | Finaled | $2,000 | EPC - Replace Existing Fire Panel with like panel with onboard cell dialer Filed as: M3 MEP LLC |
| 4800 Florin Perkins Rd City of Sacramento · APN 061-0164-019-0000 | Fire alarm / sprinkler COM-2422393Portal ↗ | Issued Oct 24, 2024 14d review | Finaled | $2,000 | EPC - Replace existing fire panel with like panel w/internal cell dialer Filed as: M3 MEP LLC |
| 1100 Richards Blvd City of Sacramento · APN 001-0090-005-0000 | Electrical / panel COM-2418502Portal ↗ | Issued Aug 21, 2024 1d review | Finaled | $108,000 | PERMIT TO COMPLETET WORK ON EXPIRED PERMIT COM-2401209, COM-2305392 EPC - 18-005902 Install multiple food truck charging stations. Provide new ,1200A, 480/277V, 3-Phase, 4-wire building service to replace depreciated 600A, 120/208V service equipment. Provide dry type transformers and distribution to reconnect existing distribution equipment. Remove and replace and repair existing un-permitted work. ** See COM-2403809 revision for Changes to single-line drawing, revised layout of site food truck power, added bollard detail, added pole base detail, and new plans for site lighting. ** revision COM-2406046 - EPC - CHANGES TO SINGLE LINE DRAWING,REVISED LAYOUT OF SITE FOOD TRUCK POWER, ADDED BOLLARD DETAIL, ADDED POLE BASE DETAIL. REVISION COM-2403809:Changes to single-line drawing, revised layout of site food truck power, added bollard detail, added pole base detail, and new plans for site lighting.+ SEPARATE PERMIT TO BE ISSUED FOR SITE LIGHTING revision COM-2420251 1) Revise approved plans to include panel boards PNL1 and TP6 to one-line 2) Revise AIC rating for each panel board and/or mains to match field conditions or provide work to match approved plans 3) Remove second TP2 panel from one-line Filed as: M3 MEP LLC |
| 1100 Richards Blvd City of Sacramento · APN 001-0090-005-0000 | Electrical / panel COM-2401209Portal ↗ | Issued Feb 6, 2024 20d review | Expired Permit | $108,000 | PERMIT TO COMPLETET WORK ON EXPIRED PERMIT COM-2305392 EPC - 18-005902 Install multiple food truck charging stations. Provide new ,1200A, 480/277V, 3-Phase, 4-wire building service to replace depreciated 600A, 120/208V service equipment. Provide dry type transformers and distribution to reconnect existing distribution equipment. Remove and replace and repair existing un-permitted work. ** See COM-2403809 revision for Changes to single-line drawing, revised layout of site food truck power, added bollard detail, added pole base detail, and new plans for site lighting. ** REVISION COM-2403809:Changes to single-line drawing, revised layout of site food truck power, added bollard detail, added pole base detail, and new plans for site lighting.+ SEPARATE PERMIT TO BE ISSUED FOR SITE LIGHTING Filed as: M3 MEP LLC |
| 1100 Richards Blvd City of Sacramento · APN 001-0090-005-0000 | Repair tied to a housing/code case COM-2305392Portal ↗ | Issued Jul 20, 2023 122d review | Expired Permit | $160,000 | EPC - 18-005902 Install multiple food truck charging stations. Provide new ,1200A, 480/277V, 3-Phase, 4-wire building service to replace depreciated 600A, 120/208V service equipment. Provide dry type transformers and distribution to reconnect existing distribution equipment. Remove and replace and repair existing un-permitted work. Filed as: M3 MEP LLC |