Active in City of Sacramento (80 permits)
Raw permit filing name: OLDTOWN ELECTRIC INC
76 issued · 69 parcels
vs 11 prior 24m(+527%)
19 construction/remodel
Sum of permit job values
Application → issuance
Latest: Oct 16, 2026
Where this builder's geocoded permits cluster
Compares this builder's median days from permit application to issuance against all peer permits in City of Sacramento (trailing 5-year benchmark).
| Permit Category | Permits | Issued | Units | Declared Valuation | Builder Median Review | City Median (75th pct) | Relative Pace |
|---|---|---|---|---|---|---|---|
| 58 | 56 | — | $269,576 | 0d (n=56) | 0d (0d p75) | Within typical range | |
| 19 | 19 | — | $24,711 | 6d (n=19) | 4d (21d p75) | Within typical range | |
| 2 | 0 | — | — | — | 41d (93d p75) | — | |
| 1 | 1 | — | $1,500 | — | 0d (0d p75) | — |
Click any address to open the full property dossier or inspect the official agency record
| Property / Parcel | Record & Category | Applied / Issued | Status | Valuation | Work Description & Raw Attribution |
|---|---|---|---|---|---|
| 1809 19th St City of Sacramento · APN 010-0023-014-0000 | Electrical / panel COM-2623155Portal ↗ | Issued Oct 16, 2026 1d review | Issued | $9,625 | PANEL REPLACEMENT: (LIKE FOR LIKE)DEMOLITION EXISTING ELECTRICAL PANEL AND REPLACING IT WITH NEW 200 AMP PANEL. SUB PANEL REPLACEMENT: REMOVE 2 EXISTING SUB PANELS AND REPLACE WITH NEW 200-AMP 30/60 SPACE SUB PANEL RELOCATE FROM SECOND FLOOR TO FIRST FLOOR CARBON MONOXIDE & SMOKE ALARMS ARE REQUIRED. REFERENCE CRC SECTIONS R310.1 & R311.1. ALL WORK IS SUBJECT TO FIELD INSPECTION Filed as: OLDTOWN ELECTRIC INC |
| 10 Ridgemark Ct City of Sacramento · APN 031-0350-007-0000 | Remodel / interior alteration RES-2622909Portal ↗ | Issued Oct 14, 2026 1d review | Issued | $900 | EV Charger Permit: EV Charger Install. Install a 20A GFCI breaker for a EV charger. Run 8 AWG wire from panel to EV location. Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994, are exempt). Carbon monoxide & Smoke alarms required. Reference CRC sections R310.1 & R311.1. Filed as: OLDTOWN ELECTRIC INC |
| 3031 Marshall Way City of Sacramento · APN 013-0103-016-0000 | Remodel / interior alteration RES-2619500Portal ↗ | Issued Oct 14, 2026 41d review | Issued | $2,663 | 2 Ev chargers install Filed as: OLDTOWN ELECTRIC INC |
| 1793 Azurite Way City of Sacramento · APN 225-0786-012-0000 | Remodel / interior alteration RES-2619483Portal ↗ | Issued Sep 30, 2026 27d review | Issued | $1,140 | Back-to-Panel Circuit for EV Charger (40 Amp). Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994 are exempt). ALL WORK SUBJECT TO FIELD INSPECTION. Filed as: OLDTOWN ELECTRIC INC |
| 10 Ridgemark Ct City of Sacramento · APN 031-0350-007-0000 | Electrical / panel RES-2621181Portal ↗ | Issued Sep 23, 2026 0d review | Issued | $4,170 | E-Permit: existing panel 200 Amps - Underground service, new main panel 200 Amps, N/A weather head/masthead work. Filed as: OLDTOWN ELECTRIC INC |
| 7871 Ann Arbor Way City of Sacramento · APN 053-0141-005-0000 | Electrical / panel RES-2620235Portal ↗ | Issued Sep 14, 2026 0d review | Issued | $4,150 | E-Permit: existing panel 125 Amps - Overhead service, new main panel 100 Amps, Replacement weather head/masthead work. Filed as: OLDTOWN ELECTRIC INC |
| 212 Waunita Way City of Sacramento · APN 237-0263-003-0000 | Electrical / panel RES-2618797Portal ↗ | Issued Aug 26, 2026 0d review | Issued | $1,000 | Overhead service. REMOVE AND RESECURE ELECTRICAL PANEL FOR SIDING REPAIR BEHIND PANEL. CARBON MONOXIDE & SMOKE ALARMS ARE REQUIRED. REFERENCE CRC SECTIONS R315 & R314. Filed as: OLDTOWN ELECTRIC INC |
| 2718 Marquette Dr City of Sacramento · APN 079-0115-023-0000 | Remodel / interior alteration RES-2618288Portal ↗ | Issued Aug 26, 2026 6d review | Issued | $1,290 | EV Charger Permit: EV Charger install. Run new wire from the panel to EV charger Install new 40 amp breaker Install hard wired EV charger1. Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994, are exempt). Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: OLDTOWN ELECTRIC INC |
| 6823 Greenhaven Dr City of Sacramento · APN 030-0275-022-0000 | Electrical / panel RES-2617960Portal ↗ | Issued Aug 18, 2026 1d review | Finaled | $14,260 | AA: - Underground service, rewiring 2200 sq ft. WHOLE HOUSE REWIRE. CARBON MONOXIDE & SMOKE ALARMS ARE REQUIRED. REFERENCE CRC SECTIONS R315 & R314. Filed as: OLDTOWN ELECTRIC INC |
| 1766 Pebblewood Dr City of Sacramento · APN 225-0690-036-0000 | Electrical / panel RES-2616792Portal ↗ | Issued Aug 5, 2026 1d review | Issued | $4,505 | E-Permit: existing panel 200 Amps - Underground service, new main panel 200 Amps, N/A weather head/masthead work. Filed as: OLDTOWN ELECTRIC INC |
| 481 Wanda Way City of Sacramento · APN 005-0143-007-0000 | Electrical / panel RES-2616790Portal ↗ | Issued Aug 4, 2026 0d review | Issued | $4,390 | E-Permit: existing panel 100 Amps - Overhead service, new main panel 200 Amps, Replacement weather head/masthead work. Filed as: OLDTOWN ELECTRIC INC |
| 518 S St City of Sacramento · APN 009-0056-007-0000 | Remodel / interior alteration RES-2616311Portal ↗ | Issued Aug 4, 2026 5d review | Finaled | $600 | EPC - Run 6 awg thhn wire from sub panel to ev install 60amp 2 pole breaker for ev charger. Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994, are exempt). Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: OLDTOWN ELECTRIC INC |
| 481 Wanda Way City of Sacramento · APN 005-0143-007-0000 | Electrical / panel RES-2616251Portal ↗ | Issued Jul 29, 2026 0d review | Issued | $4,390 | E-Permit: existing panel 100 Amps - Overhead service, new main panel 200 Amps, Replacement weather head/masthead work. Filed as: OLDTOWN ELECTRIC INC |
| 77 Waterglen Cir City of Sacramento · APN 078-0041-022-0000 | Remodel / interior alteration RES-2614267Portal ↗ | Issued Jul 20, 2026 13d review | Finaled | $1,248 | EPC - Install 50-amp breaker run 6/3 Romex wire from panel to EV charger location Install customer provided hard wired EV charger Filed as: OLDTOWN ELECTRIC INC |
| 6430 14th Ave City of Sacramento · APN 021-0073-023-0000 | Electrical / panel RES-2614903Portal ↗ | Issued Jul 15, 2026 1d review | Issued | $6,580 | Electrical Permit: Demolition of 2 existing electrical duplex panels and replacing them with new 100 amp panels. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: OLDTOWN ELECTRIC INC |
| 710 7th Ave City of Sacramento · APN 012-0322-041-0000 | Electrical / panel RES-2611480Portal ↗ | Issued Jun 4, 2026 1d review | Finaled | $5,400 | AA: existing panel 100 Amps - Overhead service, new main panel 200 Amps, N/A weather head/masthead work, main breaker replacement. Filed as: OLDTOWN ELECTRIC INC |
| 212 Waunita Way City of Sacramento · APN 237-0263-003-0000 | Electrical / panel RES-2611462Portal ↗ | Issued Jun 3, 2026 0d review | Finaled | $3,950 | E-Permit: existing panel 100 Amps - Overhead service, new main panel 100 Amps, Replacement weather head/masthead work. Filed as: OLDTOWN ELECTRIC INC |
| 60 Starlit Cir City of Sacramento · APN 030-0074-004-0000 | Electrical / panel RES-2611461Portal ↗ | Issued Jun 3, 2026 0d review | Finaled | $5,000 | E-Permit: existing panel 100 Amps - Underground service, new main panel 200 Amps, N/A weather head/masthead work. Filed as: OLDTOWN ELECTRIC INC |
| 1079 San Mateo Way City of Sacramento · APN 017-0041-029-0000 | Remodel / interior alteration RES-2610522Portal ↗ | Issued Jun 2, 2026 12d review | Issued | $2,355 | Run new #8 AWG wire from the panel to EV charger Install new 2 pole 40breaker Install CS EV charger. Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994, are exempt). All work subject to field inspection. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: OLDTOWN ELECTRIC INC |
| 518 S St City of Sacramento · APN 009-0056-007-0000 | Electrical / panel RES-2610801Portal ↗ | Applied May 27, 2026 | Withdrawn | $10,000 | AA: existing panel 200 Amps - Overhead service, N/A weather head/masthead work, main breaker replacement, adding 200 Amps subpanel, installation of 200 Amps replacement subpanel. The main panel is being converted to a 200 amp panel and a new main panel is being added and going to a 400 amp. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: OLDTOWN ELECTRIC INC |
| 3200 Truxel Rd City of Sacramento · APN 225-0740-015-0000 | Electrical / panel COM-2609138Portal ↗ | Issued May 22, 2026 16d review | Issued | $18,705 | EPC - Remove existing 400 amp 3 phase disconnect and 9 meters Replace with new 400 amp disconnect , 8 meters and house panel Filed as: OLDTOWN ELECTRIC INC |
| 518 S St City of Sacramento · APN 009-0056-007-0000 | Electrical / panel RES-2609979Portal ↗ | Issued May 19, 2026 4d review | Finaled | $10,000 | CONVERTING EXISTING 200 AMP METER PANEL TO 200AMP SUB PANEL, RELOCATING THE MAIN PANEL TO THE CORNER TO THE LEFT OF THE EXISTING PANEL LOCATION AND UPSIZING IT TO 400AMP. SUB PANEL REPLACEMENT: UPGRADE EXISTING 100 AMP SUB PANEL TO 200 AMP. APPLICANT WILL NEED TO PAINT THE METER BOX AND RISER TO MATCH HOUSE. CARBON MONOXIDE & SMOKE ALARMS ARE REQUIRED. REFERENCE CRC SECTIONS R315 & R314. ALL WORK IS SUBJECT TO FIELD INSPECTION. Filed as: OLDTOWN ELECTRIC INC |
| 6825 Greenhaven Dr City of Sacramento · APN 030-0275-022-0000 | Electrical / panel RES-2610078Portal ↗ | Issued May 18, 2026 0d review | Finaled | $14,260 | Electrical Permit: Whole house re-wire. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: OLDTOWN ELECTRIC INC |
| 3012 Mulvaney Ave City of Sacramento · APN 225-3090-027-0000 | Remodel / interior alteration RES-2609506Portal ↗ | Issued May 14, 2026 3d review | Issued | $990 | Install new box and Ev outlet on the back of the panel run wire from a panel to the outlet install 40 amp GFCI breaker. Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994, are exempt). All work subject to field inspection. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: OLDTOWN ELECTRIC INC |
| 2601 D St City of Sacramento · APN 003-0096-022-0000 | Electrical / panel RES-2609457Portal ↗ | Issued May 11, 2026 0d review | Finaled | $2,501 | Electrical Permit-Add new circuit for induction stove. Install new breaker. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: OLDTOWN ELECTRIC INC |