Active in City of Sacramento (14 permits)
Raw permit filing name: Q7 ROOFING & WATERPROOFING INC
14 issued · 1 parcels
vs 0 prior 24m
0 construction/remodel
Sum of permit job values
Application → issuance
Latest: Aug 6, 2026
Where this builder's geocoded permits cluster
Compares this builder's median days from permit application to issuance against all peer permits in City of Sacramento (trailing 5-year benchmark).
| Permit Category | Permits | Issued | Units | Declared Valuation | Builder Median Review | City Median (75th pct) | Relative Pace |
|---|---|---|---|---|---|---|---|
| 14 | 14 | — | $210,910 | 8d (n=14) | 0d (0d p75) | Above 75th pct turnaround |
Click any address to open the full property dossier or inspect the official agency record
| Property / Parcel | Record & Category | Applied / Issued | Status | Valuation | Work Description & Raw Attribution |
|---|---|---|---|---|---|
| 5200 Broadway 16 City of Sacramento · APN 015-0041-009-0000 | Roof replacement COM-2616242Portal ↗ | Issued Aug 6, 2026 8d review | Finaled | $15,000 | Roof Permit: FOR BLDG 4, Units 15-18: Removal and Disposal of existing comp shingle roofing 1 layer, Removal and Reinstall of existing skylights as needed, GAF Tiger Paw Underlayment (Class A) using 7/8” plastic caps, GAF Master Flow Vents (1 per every 300SqFt.) per manufacturer guidelines for proper attic & roof ventilation. New step flashing at all roof to wall locations. New 2x2 drip edge at perimeter. Provide and install new roof jacks per manufacture recommendations. GAF Self Adhered Membrane at Valleys, Pipes, Roof Transitions, Rake Walls and Sensitive Areas, GAF Timberline HDZ RSGAF 10” Ridge/Hip Timber crest where conditions apply using roof coil nails. CRRC: 0676-0131 Filed as: Q7 ROOFING & WATERPROOFING INC |
| 5200 Broadway 68 City of Sacramento · APN 015-0041-009-0000 | Roof replacement COM-2616237Portal ↗ | Issued Aug 6, 2026 8d review | Finaled | $15,000 | Roof Permit: FOR BLDG 15, Units 67-70: Removal and Disposal of existing comp shingle roofing 1 layer, Removal and Reinstall of existing skylights as needed, GAF Tiger Paw Underlayment (Class A) using 7/8” plastic caps, GAF Master Flow Vents (1 per every 300SqFt.) per manufacturer guidelines for proper attic & roof ventilation. New step flashing at all roof to wall locations. New 2x2 drip edge at perimeter. Provide and install new roof jacks per manufacture recommendations. GAF Self Adhered Membrane at Valleys, Pipes, Roof Transitions, Rake Walls and Sensitive Areas, GAF Timberline HDZ RSGAF 10” Ridge/Hip Timber crest where conditions apply using roof coil nails. CRRC: 0676-0131 Filed as: Q7 ROOFING & WATERPROOFING INC |
| 5200 Broadway 29 City of Sacramento · APN 015-0041-009-0000 | Roof replacement COM-2616232Portal ↗ | Issued Aug 6, 2026 8d review | Finaled | $15,000 | Roof Permit: FOR BLDG 7, Units 29-34: Removal and Disposal of existing comp shingle roofing 1 layer, Removal and Reinstall of existing skylights as needed, GAF Tiger Paw Underlayment (Class A) using 7/8” plastic caps, GAF Master Flow Vents (1 per every 300SqFt.) per manufacturer guidelines for proper attic & roof ventilation. New step flashing at all roof to wall locations. New 2x2 drip edge at perimeter. Provide and install new roof jacks per manufacture recommendations. GAF Self Adhered Membrane at Valleys, Pipes, Roof Transitions, Rake Walls and Sensitive Areas, GAF Timberline HDZ RSGAF 10” Ridge/Hip Timber crest where conditions apply using roof coil nails. CRRC: 0676-0131 Filed as: Q7 ROOFING & WATERPROOFING INC |
| 5200 Broadway 20 City of Sacramento · APN 015-0041-009-0000 | Roof replacement COM-2616228Portal ↗ | Issued Aug 6, 2026 8d review | Finaled | $15,910 | Roof Permit: FOR BLDG 5, Units 19-24: Removal and Disposal of existing comp shingle roofing 1 layer, Removal and Reinstall of existing skylights as needed, GAF Tiger Paw Underlayment (Class A) using 7/8” plastic caps, GAF Master Flow Vents (1 per every 300SqFt.) per manufacturer guidelines for proper attic & roof ventilation. New step flashing at all roof to wall locations. New 2x2 drip edge at perimeter. Provide and install new roof jacks per manufacture recommendations. GAF Self Adhered Membrane at Valleys, Pipes, Roof Transitions, Rake Walls and Sensitive Areas, GAF Timberline HDZ RSGAF 10” Ridge/Hip Timber crest where conditions apply using roof coil nails. CRRC: 0676-0131 Filed as: Q7 ROOFING & WATERPROOFING INC |
| 5200 Broadway 10 City of Sacramento · APN 015-0041-009-0000 | Roof replacement COM-2615843Portal ↗ | Issued Jul 31, 2026 7d review | Finaled | $15,000 | REMOVAL AND DISPOSAL OF EXISTING COMP SHINGLE ROOFING. 1 LAYER. 37 SQUARES. INSTALL ASPHALT SHINGLES. REMOVAL AND REINSTALL OF EXISTING SKYLIGHTS AS NEEDED. GAF TIGER PAW UNDERLAYMENT (CLASS A) USING 7/8” PLASTIC CAPS, GAF MASTER FLOW VENTS (1 PER EVERY 300SQFT.) PER MANUFACTURER GUIDELINES FOR PROPER ATTIC & ROOF VENTILATION. NEW STEP FLASHING AT ALL ROOF TO WALL LOCATIONS. NEW 2X2 DRIP EDGE AT PERIMETER. PROVIDE AND INSTALL NEW ROOF JACKS PER MANUFACTURE RECOMMENDATIONS. GAF SELF ADHERED MEMBRANE AT VALLEYS, PIPES, ROOF TRANSITIONS, RAKE WALLS AND SENSITIVE AREAS, GAF TIMBERLINE HDZ RSGAF 10” RIDGE/HIP TIMBER CREST WHERE CONDITIONS APPLY USING ROOF COIL NAILS. IN-PROGRESS INSPECTION REQUIRED IF 10 SQUARES OR GREATER. CF-1R-ALT ON FILE. CF-6R-ENV-01 REQUIRED AT FINAL INSPECTION. CARBON MONOXIDE & SMOKE ALARMS ARE REQUIRED. REFERENCE CRC SECTIONS R315 & R314. ALL WORK IS SUBJECT TO FIELD INSPECTION. Filed as: Q7 ROOFING & WATERPROOFING INC |
| 5200 Broadway 13 City of Sacramento · APN 015-0041-009-0000 | Roof replacement COM-2615841Portal ↗ | Issued Jul 31, 2026 7d review | Finaled | $15,000 | REMOVAL AND DISPOSAL OF EXISTING COMP SHINGLE ROOFING. 1 LAYER. 37 SQUARES. INSTALL ASPHALT SHINGLES. REMOVAL AND REINSTALL OF EXISTING SKYLIGHTS AS NEEDED. GAF TIGER PAW UNDERLAYMENT (CLASS A) USING 7/8” PLASTIC CAPS, GAF MASTER FLOW VENTS (1 PER EVERY 300SQFT.) PER MANUFACTURER GUIDELINES FOR PROPER ATTIC & ROOF VENTILATION. NEW STEP FLASHING AT ALL ROOF TO WALL LOCATIONS. NEW 2X2 DRIP EDGE AT PERIMETER. PROVIDE AND INSTALL NEW ROOF JACKS PER MANUFACTURE RECOMMENDATIONS. GAF SELF ADHERED MEMBRANE AT VALLEYS, PIPES, ROOF TRANSITIONS, RAKE WALLS AND SENSITIVE AREAS, GAF TIMBERLINE HDZ RSGAF 10” RIDGE/HIP TIMBER CREST WHERE CONDITIONS APPLY USING ROOF COIL NAILS. IN-PROGRESS INSPECTION REQUIRED IF 10 SQUARES OR GREATER. CF-1R-ALT ON FILE. CF-6R-ENV-01 REQUIRED AT FINAL INSPECTION. CARBON MONOXIDE & SMOKE ALARMS ARE REQUIRED. REFERENCE CRC SECTIONS R315 & R314. ALL WORK IS SUBJECT TO FIELD INSPECTION. Filed as: Q7 ROOFING & WATERPROOFING INC |
| 5200 Broadway 12 City of Sacramento · APN 015-0041-009-0000 | Roof replacement COM-2615813Portal ↗ | Issued Jul 31, 2026 8d review | Finaled | $15,000 | REMOVAL AND DISPOSAL OF EXISTING COMP SHINGLE ROOFING. 1 LAYER. 37 SQUARES. INSTALL ASPHALT SHINGLES. REMOVAL AND REINSTALL OF EXISTING SKYLIGHTS AS NEEDED, GAF TIGER PAW UNDERLAYMENT (CLASS A) USING 7/8” PLASTIC CAPS, GAF MASTER FLOW VENTS (1 PER EVERY 300SQFT.) PER MANUFACTURER GUIDELINES FOR PROPER ATTIC & ROOF VENTILATION. NEW STEP FLASHING AT ALL ROOF TO WALL LOCATIONS. NEW 2X2 DRIP EDGE AT PERIMETER. PROVIDE AND INSTALL NEW ROOF JACKS PER MANUFACTURE RECOMMENDATIONS. GAF SELF ADHERED MEMBRANE AT VALLEYS, PIPES, ROOF TRANSITIONS, RAKE WALLS AND SENSITIVE AREAS, GAF TIMBERLINE HDZ RSGAF 10” RIDGE/HIP TIMBER CREST WHERE CONDITIONS APPLY USING ROOF COIL NAILS. IN-PROGRESS INSPECTION REQUIRED IF 10 SQUARES OR GREATER. CF-1R-ALT ON FILE. CF-6R-ENV-01 REQUIRED AT FINAL INSPECTION. CARBON MONOXIDE & SMOKE ALARMS ARE REQUIRED. REFERENCE CRC SECTIONS R315 & R314. ALL WORK IS SUBJECT TO FIELD INSPECTION. Filed as: Q7 ROOFING & WATERPROOFING INC |
| 5200 Broadway 6 City of Sacramento · APN 015-0041-009-0000 | Roof replacement COM-2616321Portal ↗ | Issued Jul 30, 2026 0d review | Finaled | $15,000 | REMOVAL AND DISPOSAL OF EXISTING COMP SHINGLE ROOFING. 1 LAYER. 37 SQUARES. INSTALL ASPHALT SHINGLES. REMOVAL AND REINSTALL OF EXISTING SKYLIGHTS AS NEEDED. GAF TIGER PAW UNDERLAYMENT (CLASS A) USING 7/8” PLASTIC CAPS, GAF MASTER FLOW VENTS (1 PER EVERY 300SQFT.) PER MANUFACTURER GUIDELINES FOR PROPER ATTIC & ROOF VENTILATION. NEW STEP FLASHING AT ALL ROOF TO WALL LOCATIONS. NEW 2X2 DRIP EDGE AT PERIMETER. PROVIDE AND INSTALL NEW ROOF JACKS PER MANUFACTURE RECOMMENDATIONS. GAF SELF ADHERED MEMBRANE AT VALLEYS, PIPES, ROOF TRANSITIONS, RAKE WALLS AND SENSITIVE AREAS, GAF TIMBERLINE HDZ RSGAF 10” RIDGE/HIP TIMBER CREST WHERE CONDITIONS APPLY USING ROOF COIL NAILS. IN-PROGRESS INSPECTION REQUIRED IF 10 SQUARES OR GREATER. CF-1R-ALT ON FILE. CF-6R-ENV-01 REQUIRED AT FINAL INSPECTION. CARBON MONOXIDE & SMOKE ALARMS ARE REQUIRED. REFERENCE CRC SECTIONS R315 & R314. ALL WORK IS SUBJECT TO FIELD INSPECTION. Filed as: Q7 ROOFING & WATERPROOFING INC |
| 5200 Broadway 1 City of Sacramento · APN 015-0041-009-0000 | Roof replacement COM-2615664Portal ↗ | Issued Jul 30, 2026 8d review | Finaled | $15,000 | E-Permit: Tear Off - Yes, Resheet - No, 1 layer(s), 37 squares of 30yr Laminated Dimensional Composition. CRRC: 0676-0131. . Tear off, re-sheet, install 37 squares of 30 yr laminated dimensional composition roofing material. In-progress inspection required if 10 sq or greater. CF-6R-ENV-01 required at final inspection. CF-1R-ALT on file. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314 Filed as: Q7 ROOFING & WATERPROOFING INC |
| 5200 Broadway 1 City of Sacramento · APN 015-0041-009-0000 | Roof replacement COM-2615663Portal ↗ | Issued Jul 30, 2026 8d review | Finaled | $15,000 | E-Permit: Tear Off - Yes, Resheet - No, 1 layer(s), 37 squares of 30yr Laminated Dimensional Composition. CRRC: 0676-0131. . Tear off, re-sheet, install 37 squares of 30 yr laminated dimensional composition roofing material. In-progress inspection required if 10 sq or greater. CF-6R-ENV-01 required at final inspection. CF-1R-ALT on file. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314 Filed as: Q7 ROOFING & WATERPROOFING INC |
| 5200 Broadway 1 City of Sacramento · APN 015-0041-009-0000 | Roof replacement COM-2615660Portal ↗ | Issued Jul 30, 2026 8d review | Finaled | $15,000 | E-Permit: Tear Off - Yes, Resheet - No, 1 layer(s), 37 squares of 30yr Laminated Dimensional Composition. CRRC: 0676-0131. . Tear off, re-sheet, install 37 squares of 30 yr laminated dimensional composition roofing material. In-progress inspection required if 10 sq or greater. CF-6R-ENV-01 required at final inspection. CF-1R-ALT on file. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314 Filed as: Q7 ROOFING & WATERPROOFING INC |
| 5200 Broadway 9 City of Sacramento · APN 015-0041-009-0000 | Roof replacement COM-2615785Portal ↗ | Issued Jul 29, 2026 6d review | Finaled | $15,000 | REMOVAL AND DISPOSAL OF EXISTING COMP SHINGLE ROOFING. 1 LAYER. 37 SQUARES. INSTALL ASPHALT SHINGLES. REMOVAL AND REINSTALL OF EXISTING SKYLIGHTS AS NEEDED. GAF TIGER PAW UNDERLAYMENT (CLASS A) USING 7/8” PLASTIC CAPS, GAF MASTER FLOW VENTS (1 PER EVERY 300SQFT.) PER MANUFACTURER GUIDELINES FOR PROPER ATTIC & ROOF VENTILATION. NEW STEP FLASHING AT ALL ROOF TO WALL LOCATIONS. NEW 2X2 DRIP EDGE AT PERIMETER. PROVIDE AND INSTALL NEW ROOF JACKS PER MANUFACTURE RECOMMENDATIONS. GAF SELF ADHERED MEMBRANE AT VALLEYS, PIPES, ROOF TRANSITIONS, RAKE WALLS AND SENSITIVE AREAS, GAF TIMBERLINE HDZ RSGAF 10” RIDGE/HIP TIMBER CREST WHERE CONDITIONS APPLY USING ROOF COIL NAILS. IN-PROGRESS INSPECTION REQUIRED IF 10 SQUARES OR GREATER. CF-1R-ALT ON FILE. CF-6R-ENV-01 REQUIRED AT FINAL INSPECTION. CARBON MONOXIDE & SMOKE ALARMS ARE REQUIRED. REFERENCE CRC SECTIONS R315 & R314. ALL WORK IS SUBJECT TO FIELD INSPECTION. Filed as: Q7 ROOFING & WATERPROOFING INC |
| 5200 Broadway 8 City of Sacramento · APN 015-0041-009-0000 | Roof replacement COM-2615838Portal ↗ | Issued Jul 28, 2026 4d review | Finaled | $15,000 | REMOVAL AND DISPOSAL OF EXISTING COMP SHINGLE ROOFING. 1 LAYER. 37 SQUARES. INSTALL ASPHALT SHINGLES. REMOVAL AND REINSTALL OF EXISTING SKYLIGHTS AS NEEDED, GAF TIGER PAW UNDERLAYMENT (CLASS A) USING 7/8” PLASTIC CAPS, GAF MASTER FLOW VENTS (1 PER EVERY 300SQFT.) PER MANUFACTURER GUIDELINES FOR PROPER ATTIC & ROOF VENTILATION. NEW STEP FLASHING AT ALL ROOF TO WALL LOCATIONS. NEW 2X2 DRIP EDGE AT PERIMETER. PROVIDE AND INSTALL NEW ROOF JACKS PER MANUFACTURE RECOMMENDATIONS. GAF SELF ADHERED MEMBRANE AT VALLEYS, PIPES, ROOF TRANSITIONS, RAKE WALLS AND SENSITIVE AREAS, GAF TIMBERLINE HDZ RSGAF 10” RIDGE/HIP TIMBER CREST WHERE CONDITIONS APPLY USING ROOF COIL NAILS. IN-PROGRESS INSPECTION REQUIRED IF 10 SQUARES OR GREATER. CF-1R-ALT ON FILE. CF-6R-ENV-01 REQUIRED AT FINAL INSPECTION. CARBON MONOXIDE & SMOKE ALARMS ARE REQUIRED. REFERENCE CRC SECTIONS R315 & R314. ALL WORK IS SUBJECT TO FIELD INSPECTION. Filed as: Q7 ROOFING & WATERPROOFING INC |
| 5200 Broadway 1 City of Sacramento · APN 015-0041-009-0000 | Roof replacement COM-2615657Portal ↗ | Issued Jul 28, 2026 6d review | Finaled | $15,000 | E-Permit: Tear Off - Yes, Resheet - No, 1 layer(s), 37 squares of 30yr Laminated Dimensional Composition. CRRC: 0676-0131. Tear off, re-sheet, install 37 squares of 30 yr laminated dimensional composition roofing material. In-progress inspection required if 10 sq or greater. CF-6R-ENV-01 required at final inspection. CF-1R-ALT on file. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314 Filed as: Q7 ROOFING & WATERPROOFING INC |