Active in City of Sacramento (138 permits)
Raw permit filing name: R J A HEATING & AIR INC
132 issued · 119 parcels
vs 24 prior 24m(+104%)
3 construction/remodel
Sum of permit job values
Application → issuance
Latest: Oct 6, 2026
Where this builder's geocoded permits cluster
Compares this builder's median days from permit application to issuance against all peer permits in City of Sacramento (trailing 5-year benchmark).
| Permit Category | Permits | Issued | Units | Declared Valuation | Builder Median Review | City Median (75th pct) | Relative Pace |
|---|---|---|---|---|---|---|---|
| 82 | 82 | — | $1,008,307 | 0d (n=82) | 0d (0d p75) | Within typical range | |
| 52 | 46 | 5 | $893,654 | 0d (n=46) | 0d (0d p75) | Within typical range | |
| 3 | 3 | — | $37,574 | 28d (n=3) | 4d (21d p75) | Above 75th pct turnaround | |
| 1 | 1 | — | $21,555 | — | 0d (0d p75) | — |
Click any address to open the full property dossier or inspect the official agency record
| Property / Parcel | Record & Category | Applied / Issued | Status | Valuation | Work Description & Raw Attribution |
|---|---|---|---|---|---|
| 2020 29th St City of Sacramento · APN 010-0123-021-0000 | Roof replacement COM-2622099Portal ↗ | Issued Oct 6, 2026 1d review | Issued | $30,863 | HVAC CHANGE OUT; 4 HP PACKAGE SYSTEM, ALL ROOF MOUNTED, REPLACE SOME DUCT WORK - LIKE FOR LIKE. (3) 2.5 TON PKG UNIT. (1) 3 TON PKG UNIT. NRCC-MCH-E ON FILE. THE EXISTING UNIT SHALL BE REMOVED. THE NEW UNIT SHALL BE PLACED IN THE SAME LOCATION AS THE EXISTING UNIT. ROOF TOP INSTALLATIONS WILL BE LOCATED ON THE BACK ROOF SLOPES AND BELOW THE RIDGE LINES, AND NOT VISIBLE FROM THE STREET. ALL WORK IS SUBJECT TO FIELD INSPECTION. Filed as: R J A HEATING & AIR INC |
| 1235 Broadway City of Sacramento · APN 009-0252-010-0000 | Roof replacement COM-2620204Portal ↗ | Issued Sep 15, 2026 1d review | Issued | $34,420 | HVAC C/O 6 - 5 TON HP PACKAGE SYSTEMS, ROOF MOUNTED, NO DUCT WORK, LIKE FOR LIKE. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: R J A HEATING & AIR INC |
| 1928 L St City of Sacramento · APN 007-0143-007-0000 | Roof replacement COM-2620214Portal ↗ | Applied Sep 14, 2026 | Applied | $15,159 | HVAC Permit: HVAC Change out, HP Package system, roof mounted, no duct work - like for like. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. ALL WORK SUBJECT TO FIELD INSPECTION. Filed as: R J A HEATING & AIR INC |
| 2 Riverport Cir City of Sacramento · APN 031-0260-056-0000 | HVAC / heat pump RES-2619924Portal ↗ | Issued Sep 9, 2026 0d review | Finaled | $13,570 | Change-out Split System (all-electric heat pump) to Split System (all-electric heat pump). The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. Filed as: R J A HEATING & AIR INC |
| 5690 Lawler St City of Sacramento · APN 201-0630-062-0000 | HVAC / heat pump RES-2615227Portal ↗ | Issued Jul 17, 2026 0d review | Finaled | $12,126 | No Duct Work Permitted. Change-out Split System to Split System. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. Filed as: R J A HEATING & AIR INC |
| 4030 Truxel Rd City of Sacramento · APN 225-1250-045-0000 | HVAC / heat pump COM-2613104Portal ↗ | Issued Jul 16, 2026 24d review | Issued | $12,458 | EPC - REMOVE/REPLACE (1) HVAC RTU LIKE FOR LIKE. Filed as: R J A HEATING & AIR INC |
| 2 Riverport Cir City of Sacramento · APN 031-0260-056-0000 | HVAC / heat pump RES-2614660Portal ↗ | Issued Jul 10, 2026 0d review | Issued | $13,570 | No Duct Work Permitted. Change-out Split System to Split System (all-electric heat pump). The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. Filed as: R J A HEATING & AIR INC |
| 4030 Truxel Rd City of Sacramento · APN 225-1250-045-0000 | Remodel / interior alteration COM-2612151Portal ↗ | Issued Jul 9, 2026 28d review | Issued | $12,458 | EPC - HVAC Change out, STE A Filed as: R J A HEATING & AIR INC |
| 4150 Truxel Rd 130 City of Sacramento · APN 225-1250-039-0000 | HVAC / heat pump COM-2612150Portal ↗ | Issued Jul 7, 2026 26d review | Issued | $8,513 | EPC - HVAC Change out Filed as: R J A HEATING & AIR INC |
| 6655 Fordham Way City of Sacramento · APN 024-0366-009-0000 | Roof replacement RES-2614027Portal ↗ | Issued Jul 2, 2026 0d review | Finaled | $16,670 | Change-out w/new ducts Roof Mount to Roof Mount. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. Filed as: R J A HEATING & AIR INC |
| 6623 Valley Hi Dr City of Sacramento · APN 117-0012-010-0000 | HVAC / heat pump COM-2613572Portal ↗ | Issued Jul 1, 2026 5d review | Finaled | $42,413 | HVAC change out, 1 unit - Like for like (Luck Donut ) Filed as: R J A HEATING & AIR INC |
| 6623 Valley Hi Dr City of Sacramento · APN 117-0012-010-0000 | Roof replacement COM-2613601Portal ↗ | Applied Jun 29, 2026 | Ready-to-Issue | $12,555 5 units | HVAC Permit: FOR LUCKY DONUT- HVAC Change out, HP Package system, roof mounted, no duct work - like for like. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: R J A HEATING & AIR INC |
| 7500 14th Ave City of Sacramento · APN 021-0101-039-0000 | Remodel / interior alteration COM-2607760Portal ↗ | Issued Jun 25, 2026 66d review | Finaled | $12,445 | EPC - Adding a ductless muti split system. one outdoor unit and 3 indoor heads wall mounted. Filed as: R J A HEATING & AIR INC |
| 6623 Valley Hi Dr City of Sacramento · APN 117-0012-010-0000 | Roof replacement COM-2612580Portal ↗ | Issued Jun 17, 2026 1d review | Issued | $42,413 | HVAC CHANGE OUT, HP PACKAGE SYSTEM, HP CONDENSER ONLY, BOTH ROOF MOUNTED, NO DUCT WORK - LIKE FOR LIKE. (1) 4 TON PKG UNIT. (2) 3 1/2 TON CONDENSER ONLY. NO DUCT WORK PERMITTED. THE EXISTING UNIT SHALL BE REMOVED. THE NEW UNIT SHALL BE PLACED IN THE SAME LOCATION AS THE EXISTING UNIT. ROOF TOP INSTALLATIONS WILL BE LOCATED ON THE BACK ROOF SLOPES AND BELOW THE RIDGE LINES, AND NOT VISIBLE FROM THE STREET. CF-1R-ALT-HVAC ON FILE. CARBON MONOXIDE & SMOKE ALARMS ARE REQUIRED. REFERENCE CRC SECTIONS R315 & R314. ALL WORK IS SUBJECT TO FIELD INSPECTION. Filed as: R J A HEATING & AIR INC |
| 6623 Valley Hi Dr City of Sacramento · APN 117-0012-010-0000 | Roof replacement COM-2612365Portal ↗ | Applied Jun 15, 2026 | Void | $42,413 | HVAC Permit: HVAC Change out, HP Package system, HP condenser only, both roof mounted, no duct work - like for like. 1 - 4 ton pkg unit. 1 - 3 1/2 ton condenser only. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: R J A HEATING & AIR INC |
| 1901 16th St City of Sacramento · APN 009-0094-004-0000 | Roof replacement COM-2612091Portal ↗ | Issued Jun 12, 2026 2d review | Finaled | $7,570 | HVAC CHANGE OUT, SPLIT HP SYSTEM, ROOF MOUNTED, NO DUCT WORK, LIKE FOR LIKE. NO DUCT WORK PERMITTED. THE EXISTING UNIT SHALL BE REMOVED. THE NEW UNIT SHALL BE PLACED IN THE SAME LOCATION AS THE EXISTING UNIT. CF-1R-ALT-HVAC ON FILE. CF1R REQUIRED AT FINAL INSPECTION. CARBON MONOXIDE & SMOKE ALARMS ARE REQUIRED. REFERENCE CRC SECTIONS R315 & R314. ALL WORK IS SUBJECT TO FIELD INSPECTION. Filed as: R J A HEATING & AIR INC |
| 6125 Stockton Blvd 65 City of Sacramento · APN 038-0081-014-0000 | HVAC / heat pump COM-2611474Portal ↗ | Issued Jun 4, 2026 1d review | Finaled | $2,460 | WALL FURNACE CHANGE OUT, GAS WALL FURNACE - LIKE FOR LIKE. THE EXISTING UNIT SHALL BE REMOVED. THE NEW UNIT SHALL BE PLACED IN THE SAME LOCATION AS THE EXISTING UNIT. AS NOTED ON FORM CDD-0036, APPLIANCES HEAVIER THAN 400LBS REQUIRE ENGINEERING CALCULATIONS. CF-1R-ALT-HVAC ON FILE. CARBON MONOXIDE & SMOKE ALARMS ARE REQUIRED. REFERENCE CRC SECTIONS R315 & R314. ALL WORK IS SUBJECT TO FIELD INSPECTION. Filed as: R J A HEATING & AIR INC |
| 6125 Stockton Blvd 64 City of Sacramento · APN 038-0081-014-0000 | HVAC / heat pump COM-2611471Portal ↗ | Issued Jun 4, 2026 1d review | Finaled | $2,460 | WALL FURNACE CHANGE OUT, GAS WALL FURNACE - LIKE FOR LIKE. THE EXISTING UNIT SHALL BE REMOVED. THE NEW UNIT SHALL BE PLACED IN THE SAME LOCATION AS THE EXISTING UNIT. AS NOTED ON FORM CDD-0036, APPLIANCES HEAVIER THAN 400LBS REQUIRE ENGINEERING CALCULATIONS. CF-1R-ALT-HVAC ON FILE. CARBON MONOXIDE & SMOKE ALARMS ARE REQUIRED. REFERENCE CRC SECTIONS R315 & R314. ALL WORK IS SUBJECT TO FIELD INSPECTION. Filed as: R J A HEATING & AIR INC |
| 2399 Northgate Blvd City of Sacramento · APN 274-0110-052-0000 | Roof replacement COM-2609185Portal ↗ | Issued May 7, 2026 0d review | Finaled | $20,312 | HVAC Permit: HVAC change out, 2 HP package unit, roof mounted, no duct work - like for like. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: R J A HEATING & AIR INC |
| 2231 Northview Dr City of Sacramento · APN 274-0110-055-0000 | HVAC / heat pump COM-2608330Portal ↗ | Issued Apr 28, 2026 1d review | Issued | $40,240 | HVAC change out, 3 HP split systems, Condenser is ground mounted, no duct work - Like for like (2 - 4ton units, 1 - 3ton unit) Replacing water heater as well with a 50 gal HP water heater - like for like. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit. CF-1R-ALT-HVAC on file. Carbon monoxide & Smoke alarms are required. Reference CRC sections R315 & R314. All work is subject to field inspection. Filed as: R J A HEATING & AIR INC |
| 2835 Norwood Ave City of Sacramento · APN 263-0283-027-0000 | Roof replacement COM-2607360Portal ↗ | Issued Apr 17, 2026 3d review | Issued | $8,893 | HVAC change out, HP package unit, roof mounted, no duct work - like for like. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit. CF-1R-ALT-HVAC on file. Water Heater Permit: Replacing 2 water heaters - 65 gallon HP water heater. Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994, are exempt). Carbon monoxide & Smoke alarms are required. Reference CRC sections R315 & R314. All work is subject to field inspection. Filed as: R J A HEATING & AIR INC |
| 1301 I St City of Sacramento · APN 006-0053-021-0000 | Roof replacement COM-2604143Portal ↗ | Issued Apr 8, 2026 36d review | Issued | $64,373 | HVAC Change out - 7 Split HP unit, roof mounted, no duct work - like for like 4 - 5 ton units 2 - 4 ton units 1 - 3 ton unit As noted on form CDD-0036, appliances heavier than 400lbs require engineering calculations. Provide engineered calculations and specifications for anchorage of new HVAC unit to existing structure per ASCE 7-16 §13.1.4 and §13.6 (e.g., clips/fasteners from new HVAC unit to existing curb/structure). All work subject to field inspection. Filed as: R J A HEATING & AIR INC |
| 2835 Norwood Ave City of Sacramento · APN 263-0283-027-0000 | Plumbing / water heater / sewer COM-2606812Portal ↗ | Issued Apr 7, 2026 0d review | Withdrawn | $21,555 | Water Heater Permit: Replacing 2 water heaters - 65 gallon HP water heater. Water conserving fixtures are required to be installed throughout this residence per SB 407 (Note: Residences built after January 1, 1994, are exempt). Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: R J A HEATING & AIR INC |
| 2850 Northgate Blvd City of Sacramento · APN 262-0122-019-0000 | Roof replacement COM-2603160Portal ↗ | Issued Feb 24, 2026 6d review | Issued | $10,757 | HVAC Permit: HVAC change out of a package HP unit, roof mounted, no duct work-like for like. Filed as: R J A HEATING & AIR INC |
| 2309 Northgate Blvd City of Sacramento · APN 274-0110-040-0000 | Roof replacement COM-2603041Portal ↗ | Issued Feb 17, 2026 0d review | Issued | $7,188 | HVAC change out, package HP unit, roof mounted, no duct work, like for like. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. All work subject to field inspection. Filed as: R J A HEATING & AIR INC |