Active in City of Sacramento (20 permits)
Raw permit filing name: WHITTAKER ELECTRICAL REPAIR & INSTALLATION
20 issued · 17 parcels
vs 13 prior 24m(−69%)
Includes 2 ADU permits
Sum of permit job values
Application → issuance
Latest: Apr 13, 2026
Where this builder's geocoded permits cluster
Compares this builder's median days from permit application to issuance against all peer permits in City of Sacramento (trailing 5-year benchmark).
| Permit Category | Permits | Issued | Units | Declared Valuation | Builder Median Review | City Median (75th pct) | Relative Pace |
|---|---|---|---|---|---|---|---|
| 14 | 14 | — | $60,076 | 0d (n=14) | 0d (0d p75) | Within typical range | |
| 4 | 4 | — | $11,563 | 4d (n=4) | 4d (21d p75) | Within typical range | |
| 2 | 2 | — | $28,580 | 4d (n=2) | 97d (172d p75) | — |
Multi-permit and HCD housing projects linked to this builder's permits
Click any address to open the full property dossier or inspect the official agency record
| Property / Parcel | Record & Category | Applied / Issued | Status | Valuation | Work Description & Raw Attribution |
|---|---|---|---|---|---|
| 1707 35th St City of Sacramento · APN 007-0371-010-0000 | Accessory dwelling unit (new or conversion) RES-2606744Portal ↗ | Issued Apr 13, 2026 7d review | Finaled | $3,000 | Electrical Permit: Rough electrical wiring of interior 1000 square feet. 2-story ADU located in the court yard. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: WHITTAKER ELECTRICAL REPAIR & INSTALLATION |
| 1707 35th St City of Sacramento · APN 007-0371-010-0000 | Accessory dwelling unit (new or conversion) RES-2606525Portal ↗ | Issued Apr 2, 2026 0d review | Finaled | $25,580 | 1. Remove 100 AMP overhead fed meter main on the East side of the property. 2. Install new 400 AMP metered service as upgrade- also overhead fed. (SMUD "cut over" will be needed after the meter has been properly tagged.) 3. Install 100 AMP sub panel in place of old, with sub feeder from new 400 AMP msp. 4. Install a 2nd underground 100 AMP sub feed approximately 11 0' to previously constructed 2 story detached ADU in courtyard VIA 2/0 aluminum. 5. Install 3rd underground/ 100 AMP sub feed approximately 165' in schedule 80 PVC along base of south side ?all on surface via 2/0 aluminum. Filed as: WHITTAKER ELECTRICAL REPAIR & INSTALLATION |
| 4024 Fotos Ct City of Sacramento · APN 021-0071-047-0000 | Electrical / panel RES-2600956Portal ↗ | Issued Jan 21, 2026 5d review | Finaled | $5,200 | REMOVE 100AMP FLUSH MOUNT AND REPLACE WITH 200 AMP SEMI-FLUSH. BRING GROUNDING UP TO CODE. AA: existing panel 100 Amps - Overhead service, new main panel 200 Amps, New Install weather head/masthead work, main breaker replacement. All work subject to field inspection. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: WHITTAKER ELECTRICAL REPAIR & INSTALLATION |
| 1811 Iris Ave City of Sacramento · APN 266-0203-018-0000 | Electrical / panel RES-2515862Portal ↗ | Issued Jul 28, 2025 0d review | Finaled | $3,800 | E-Permit: existing panel 125 Amps - Overhead service, new main panel 200 Amps, Replacement weather head/masthead work, main breaker replacement. Filed as: WHITTAKER ELECTRICAL REPAIR & INSTALLATION |
| 2003 Castro Way City of Sacramento · APN 012-0051-010-0000 | Remodel / interior alteration RES-2419701Portal ↗ | Issued Sep 19, 2024 14d review | Finaled | $3,198 | Install 60amp EV dedicated circuit to be run alongside house and out into front yard. EV charger to be wired in to 4x4 post. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. ALL WORK SUBJECT TO FIELD INSPECTION. Filed as: WHITTAKER ELECTRICAL REPAIR & INSTALLATION |
| 5611 Monalee Ave City of Sacramento · APN 005-0152-024-0000 | Electrical / panel RES-2410341Portal ↗ | Issued May 13, 2024 0d review | Finaled | $800 | E-Permit: existing panel 200 Amps - Overhead service, adding 4 recessed lighting fixtures. Filed as: WHITTAKER ELECTRICAL REPAIR & INSTALLATION |
| 5611 Monalee Ave City of Sacramento · APN 005-0152-024-0000 | Electrical / panel RES-2407227Portal ↗ | Issued Apr 5, 2024 1d review | Finaled | $20,450 | AA: existing panel 125 Amps - Overhead service, new main panel 200 Amps, Replacement weather head/masthead work, main breaker replacement. Rewire kitchen with grounded circuits, new home runs, (2) and one additional dedicated circuit for microwave. Run #12 ground wire into every receptacle/plug. Take new ground wire back to panel. Install new three prong receptacles throughout and replace all those "push button" switches throughout with either décor switches or toggle type. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. ALL WORK SUBJECT TO FIELD INSPECTION. Filed as: WHITTAKER ELECTRICAL REPAIR & INSTALLATION |
| 1904 Pebblewood Dr City of Sacramento · APN 225-0700-051-0000 | Electrical / panel RES-2403561Portal ↗ | Issued Feb 19, 2024 0d review | Finaled | $5,200 | E-Permit: existing panel 200 Amps - Underground service, new main panel 200 Amps, N/A weather head/masthead work, main breaker replacement. Filed as: WHITTAKER ELECTRICAL REPAIR & INSTALLATION |
| 725 Santa Ana Ave City of Sacramento · APN 226-0162-016-0000 | Electrical / panel RES-2315926Portal ↗ | Issued Jul 31, 2023 0d review | Finaled | $2,501 | E-Permit: existing panel 200 Amps - Underground service, new main panel 200 Amps, Replacement weather head/masthead work, main breaker replacement. Filed as: WHITTAKER ELECTRICAL REPAIR & INSTALLATION |
| 3967 E Pacific Ave City of Sacramento · APN 019-0035-003-0000 | Electrical / panel RES-2313286Portal ↗ | Issued Jun 28, 2023 0d review | Finaled | $3,500 | E-Permit: existing panel 100 Amps - Overhead service, new main panel 200 Amps, New Install weather head/masthead work, main breaker replacement. Filed as: WHITTAKER ELECTRICAL REPAIR & INSTALLATION |
| 2020 Moontree Dr City of Sacramento · APN 225-0853-001-0000 | Electrical / panel RES-2305227Portal ↗ | Issued Mar 16, 2023 0d review | Finaled | $3,100 | E-Permit: existing panel 100 Amps - Underground service, new main panel 100 AMP LIKE FOR LIKE, N/A weather head/masthead work. Filed as: WHITTAKER ELECTRICAL REPAIR & INSTALLATION |
| 3520 Astoria St City of Sacramento · APN 252-0251-016-0000 | Electrical / panel RES-2302322Portal ↗ | Issued Feb 7, 2023 0d review | Finaled | $2,950 | E-Permit: existing panel 100 Amps - Overhead service, New Install weather head/masthead work. Filed as: WHITTAKER ELECTRICAL REPAIR & INSTALLATION |
| 613 Macarthur St City of Sacramento · APN 238-0072-019-0000 | Electrical / panel RES-2301757Portal ↗ | Issued Jan 30, 2023 0d review | Expired Permit | $2,500 | E-Permit: existing panel 060 Amps - Overhead service, new main panel 125 Amps, Reuse Existing weather head/masthead work. Filed as: WHITTAKER ELECTRICAL REPAIR & INSTALLATION |
| 2229 63rd Ave City of Sacramento · APN 047-0141-002-0000 | Electrical / panel RES-2300646Portal ↗ | Issued Jan 12, 2023 0d review | Finaled | $2,200 | E-Permit: existing panel 100 Amps - Overhead service, new main panel 100 Amps, Replacement weather head/masthead work. Filed as: WHITTAKER ELECTRICAL REPAIR & INSTALLATION |
| 7050 Wavecrest Way City of Sacramento · APN 030-0640-049-0000 | Remodel / interior alteration RES-2300346Portal ↗ | Issued Jan 12, 2023 6d review | Finaled | $2,450 | INSTALL 50 AMP EV CHARGER 65' AWAY FROM PANEL ON 50 AMP GFCI PROTECTED DISCONNECT ON #6 WIRE WITH BOX PLUG. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: WHITTAKER ELECTRICAL REPAIR & INSTALLATION |
| 7050 Wavecrest Way City of Sacramento · APN 030-0640-049-0000 | Electrical / panel RES-2300229Portal ↗ | Issued Jan 5, 2023 0d review | Expired Permit | $2,000 | E-Permit: existing panel 125 Amps - Overhead service. Filed as: WHITTAKER ELECTRICAL REPAIR & INSTALLATION |
| 4120 Moss Dr City of Sacramento · APN 016-0053-001-0000 | Electrical / panel RES-2300176Portal ↗ | Issued Jan 4, 2023 0d review | Finaled | $1,025 | E-Permit: existing panel 100 Amps - Underground service, New Install weather head/masthead work. Filed as: WHITTAKER ELECTRICAL REPAIR & INSTALLATION |
| 1008 E Landing Way City of Sacramento · APN 031-1400-023-0000 | Remodel / interior alteration RES-2213772Portal ↗ | Issued Jul 1, 2022 2d review | Finaled | $2,325 | EV Charger - 240/40 AMP Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314 Filed as: WHITTAKER ELECTRICAL REPAIR & INSTALLATION |
| 4490 69th St City of Sacramento · APN 021-0251-063-0000 | Remodel / interior alteration RES-2213770Portal ↗ | Issued Jul 1, 2022 2d review | Finaled | $3,590 | EV CHARGER - 240 V/40 AMP Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314 Filed as: WHITTAKER ELECTRICAL REPAIR & INSTALLATION |
| 2281 Pierre Ave City of Sacramento · APN 052-0101-002-0000 | Electrical / panel RES-2213054Portal ↗ | Issued Jun 21, 2022 0d review | Finaled | $4,850 | MPU from 100 amp to 200 amp , addition of 60 amp sub panel- Overhead service Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314 Filed as: WHITTAKER ELECTRICAL REPAIR & INSTALLATION |