TENANT IMPROVEMENT
EPC - The permit package is or the interior build-out of permanent exhibit space including interior partitions, structural reinforcement, openings, finishes, and revisions to electrical, telecom, fire alarm, and fire sprinklers. This application includes construction of planetarium dome. Planetarium structure approved under previously submitted COM-1811608
Deferred - Smoke Stack
EPC - Deferred Approval for the Interpretive Historic Smoke Stack Design Element (listed as #3) on sheet AG0.00 in the main construction document package.
Revision - Power House
EPC - Revision to COM-1811608; This Revision contains ASI 053 which changes the physical spaces within and around the planetarium theater to comply with requirements of the theater equipment manufacturer and revise the acoustic panel configuration within the ring wall to comply with constructability review.
Revision - Curtain Wall - Power House
EPC - Revision to COM-1803505; The Scope of work for ASI 007 is to revise the curtainwall system to a metal panel system to simulate the historic roll-up door.
Revisions - Power House Slab
EPC - Revision to COM-1811608; ASI 088 will add a mat slab outside of the cafe area at the Powerhouse Science Center to facilitate future installation of a shade structure. A larger heavier slab is needed handle the future shade structure, which will be covered under a separate permit. Work does not include installation of metal louvered roof system; and no additional square footage to add mat slab.
Revision - Power House
EPC - Revision to COM-1811608; ASI 085 seeks to: Remove shaft wall furring from the east wall of the elevator shaft, Add furring to the west wall side of the elevator shaft. Add detail showing gypsum board cant strip detail at ledges over 2” deep. Revise the height of light track at the donor wall(s) and the capital campaign in Lobby (A100)
Revision
EPC - Revision to COM-1811608, Structural, life safety, plumbing, mechanical, electrical, fire, IB-H is a combination of a variety of ASI documents which have been responses to RFIs from the General Contractor.
Revision
EPC - Revision to COM-1803505, Revision to structural, life safety, plumbing, IB-G contains a variety of revisions which were released to the field as ASIs. See attached Index/Narrative for more information
Revision Outer Dome
EPC - Revision to COM-1811608, This ASI illustrates the planetarium dome outer assembly redesign and deletion of sound isolation clips. The initial design included the use of a single line of framing and Isomax sound isolation clips, the revised design includes an additional line of framing outside of the dome to create acoustic isolation and remove the sound clips.
Revision Fire Proofing
EPC - Revision to COM-1811608, Add partial weatherhood plan to the project showing the roof hatch from stair 3 and add Spray Applied Fire Resistive coating to the bottomside of the deck at the rated wall head. Add A31 (3 5/8" rated wall) with rated access hatch to separate weatherhood above non-rated mechanical space from the area above Stair 3.
POWERHOUSE SCIENCE - FIRE ALARM SYSTEM
EPC - POWERHOUSE SCIENCE - FIRE ALARM SYSTE: Provide & Install new Gamewell/FCI E3 Addressable Fire Alarm System. Voice Evacuation Panel shall be installed per Engineer of Records FA drawing set & to meet all local & current codes.
Wall Revision
EPC - Revision to COM-1811608, wall types and construction to coordinate with the acoustical report (CM Slater). Additional clarification of wall types surrounding the restrooms on the 1st floor.
Fire Proof
EPC - Revision to com-1811608, Provide fire proof detailing for head of wall where it terminates at structural steel where it is not required to be protected.
Source: City of Sacramento CDD, Issued Building Permits (Current Year) · Geography: parcel (APN as recorded on the permit) · Source updated Nov 1, 2026 · Retrieved Nov 3, 2026 · The city publishes current status without a date, so status changes are dated by the window between our snapshots.
APN 001-0190-020-0000 · 13 permits matched by address and location
Matched by checking which current parcel holds each permit's mapped point, or carries its street address. This is our inference, not an official County lineage record.
Source: Sacramento County GIS, Parcels · Geography: current parcel polygons · Source updated Nov 8, 2026 · Retrieved Nov 8, 2026
Assessed values and limited building characteristics (Sacramento County Assessor)
Search by parcel number 001-0190-019-0000. Shows direct levies and special assessments.
Search the city's permit system by address or record number
County systems may not return results for a retired number. If so, use a current parcel listed above. Most recent record here: Feb 10, 2021.