Active in City of Sacramento (68 permits)
Raw permit filing name: KEVIN L V SMITH
63 issued · 26 parcels
vs 31 prior 24m(−48%)
0 construction/remodel
Sum of permit job values
Application → issuance
Latest: Aug 6, 2026
Where this builder's geocoded permits cluster
Compares this builder's median days from permit application to issuance against all peer permits in City of Sacramento (trailing 5-year benchmark).
| Permit Category | Permits | Issued | Units | Declared Valuation | Builder Median Review | City Median (75th pct) | Relative Pace |
|---|---|---|---|---|---|---|---|
| 47 | 44 | — | $215,977 | 3d (n=44) | 0d (0d p75) | Above 75th pct turnaround | |
| 12 | 12 | — | $16,220 | 0d (n=12) | 0d (0d p75) | Within typical range | |
| 5 | 4 | — | $94,126 | 1d (n=4) | 0d (0d p75) | Above 75th pct turnaround | |
| 3 | 2 | — | $57,112 | 8d (n=2) | 3d (8d p75) | — | |
| 1 | 1 | — | $62,000 | — | 1d (3d p75) | — |
Click any address to open the full property dossier or inspect the official agency record
| Property / Parcel | Record & Category | Applied / Issued | Status | Valuation | Work Description & Raw Attribution |
|---|---|---|---|---|---|
| 7610 Rush River Dr 118 City of Sacramento · APN 031-1030-022-0000 | HVAC / heat pump COM-2616966Portal ↗ | Issued Aug 6, 2026 1d review | Finaled | $4,781 | SPLIT SYSTEM CHANGE OUT IN UNIT 118. HEAT PUMP ON THE GROUND AND AIR HANDLER IN THE CLOSET. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: KEVIN L V SMITH |
| 7530 Rush River Dr 79 City of Sacramento · APN 031-0020-097-0000 | HVAC / heat pump COM-2616584Portal ↗ | Issued Aug 3, 2026 0d review | Finaled | $4,781 | HVAC SPLIT SYSTEM CHANGE OUT IN UNIT 79 LIKE FOR LIKE. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: KEVIN L V SMITH |
| 7564 Rush River Dr 6 City of Sacramento · APN 031-0020-097-0000 | HVAC / heat pump COM-2615144Portal ↗ | Issued Jul 29, 2026 13d review | Finaled | $4,781 | HVAC Permit: FOR UNIT 6- HVAC change out split system, like for like. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: KEVIN L V SMITH |
| 7606 Rush River Dr 103 City of Sacramento · APN 031-1030-022-0000 | HVAC / heat pump COM-2611479Portal ↗ | Issued Jun 4, 2026 1d review | Finaled | $4,800 | HVAC Permit: Remove and replace HVAC split system in unit 103, like for like. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: KEVIN L V SMITH |
| 1 Shoal Ct 100 City of Sacramento · APN 030-0330-018-0000 | HVAC / heat pump COM-2610978Portal ↗ | Issued Jun 4, 2026 7d review | Issued | $4,800 | Remove and replace HVAC split system in unit 100, like for like. No duct work permitted. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314 Filed as: KEVIN L V SMITH |
| 7608 Rush River Dr City of Sacramento · APN 031-1030-022-0000 | HVAC / heat pump COM-2611001Portal ↗ | Applied May 28, 2026 | Applied | $4,800 | HVAC Permit: FOR UNIT 103- Remove and replace HVAC split system, like for like. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: KEVIN L V SMITH |
| 7602 Rush River Dr 90 City of Sacramento · APN 031-1030-022-0000 | HVAC / heat pump COM-2605221Portal ↗ | Issued Apr 6, 2026 20d review | Finaled | $4,781 | Change out existing 2 ton split system with air handler in closet and HP on the ground, like for like. No duct work permitted. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit. CF-1R-ALT-HVAC on file. Carbon monoxide & Smoke alarms are required. Reference CRC sections R315 & R314. All work is subject to field inspection. Filed as: KEVIN L V SMITH |
| 7629 Windbridge Dr 42 City of Sacramento · APN 031-1170-005-0000 | HVAC / heat pump COM-2526227Portal ↗ | Issued Dec 17, 2025 6d review | Finaled | $1,900 | HVAC Permit: FOR UNIT 42-Remove and replace HVAC split system in Unit 42 with FAU in the closet and AC on the ground. Same for same. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: KEVIN L V SMITH |
| 7600 Rush River Dr 73 City of Sacramento · APN 031-1030-022-0000 | HVAC / heat pump COM-2525190Portal ↗ | Issued Dec 4, 2025 1d review | Finaled | $2,000 | HVAC remove and replace HVAC split system in Unit 73 (like for like). HP on ground and air handler in closet. As noted on form CDD-0036, appliances heavier than 400lbs require engineering calculations. Provide engineered calculations and specifications for anchorage of new HVAC unit to existing structure per ASCE 7-16 §13.1.4 and §13.6 (e.g., clips/fasteners from new HVAC unit to existing curb/structure). All work subject to field inspection. Filed as: KEVIN L V SMITH |
| 7604 Rush River Dr 102 City of Sacramento · APN 031-1030-022-0000 | HVAC / heat pump COM-2521999Portal ↗ | Issued Nov 25, 2025 36d review | Finaled | $1,900 | "Change out existing 2-ton HVAC Split System (like for like) Air Handler in closet and HP on ground" No Duct Work Permitted. Change-out Split System (all-electric heat pump) to Split System (all-electric heat pump). The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. All work subject to field inspection. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: KEVIN L V SMITH |
| 624 Lake Front Dr 35 City of Sacramento · APN 031-1030-022-0000 | HVAC / heat pump COM-2521991Portal ↗ | Issued Nov 25, 2025 36d review | Finaled | $1,900 | "Change out existing 2-ton HVAC Split System (like for like) Air Handler in closet and HP on ground" No Duct Work Permitted. Change-out Split System (all-electric heat pump) to Split System (all-electric heat pump). The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. All work subject to field inspection. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: KEVIN L V SMITH |
| 624 Lake Front Dr 35 City of Sacramento · APN 031-1030-022-0000 | HVAC / heat pump RES-2514664Portal ↗ | Issued Jul 24, 2025 13d review | Void | $8,790 | "Change out existing 2-ton HVAC Split System (like for like) Air Handler in closet and HP on ground" No Duct Work Permitted. Change-out Split System (all-electric heat pump) to Split System (all-electric heat pump). The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. All work subject to field inspection. Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: KEVIN L V SMITH |
| 7604 Rush River Dr 102 City of Sacramento · APN 031-1030-022-0000 | HVAC / heat pump RES-2514426Portal ↗ | Issued Jul 9, 2025 0d review | Void | $8,790 | No Duct Work Permitted. Change-out Split System (all-electric heat pump) to Split System (all-electric heat pump). The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. Filed as: KEVIN L V SMITH |
| 628 Lake Front Dr 17 City of Sacramento · APN 031-1030-022-0000 | HVAC / heat pump COM-2427414Portal ↗ | Issued Dec 26, 2024 8d review | Finaled | $1,900 | HVAC Permit: For Bldg. C, Unit 17-To remove and replace HVAC split system in the same location-Like for like for unit 17. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: KEVIN L V SMITH |
| 4035 May St 77 City of Sacramento · APN 237-0200-088-0000 | HVAC / heat pump COM-2424710Portal ↗ | Issued Nov 27, 2024 19d review | Finaled | $1,900 | HVAC Permit: FOR UNIT 77-To remove and replace HVAC split system in the same location, like for like. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: KEVIN L V SMITH |
| 7590 Rush River Dr City of Sacramento · APN 031-1170-009-0000 | HVAC / heat pump COM-2423410Portal ↗ | Issued Nov 4, 2024 11d review | Finaled | $1,900 | UNIT #3 -HVAC Permit: Remove and replace 2 ton split system in unit 14 with furnace and coil in the closet and AC on the ground outside. Like for like change out. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: KEVIN L V SMITH |
| 7594 Rush River Dr 14 City of Sacramento · APN 031-1170-009-0000 | HVAC / heat pump COM-2421551Portal ↗ | Issued Oct 2, 2024 1d review | Finaled | $1,900 | HVAC Permit: Remove and replace 2 ton split system in unit 14 with furnace and coil in the closet and AC on the ground outside. Like for like change out. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: KEVIN L V SMITH |
| 6565 Valley Hi Dr 107 City of Sacramento · APN 117-0012-008-0000 | HVAC / heat pump COM-2421499Portal ↗ | Issued Oct 1, 2024 0d review | Finaled | $1,900 | HVAC Permit: Remove and replace HVAC split system in Unit #107 like for like. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: KEVIN L V SMITH |
| 6565 Valley Hi Dr 103 City of Sacramento · APN 117-0012-008-0000 | HVAC / heat pump COM-2421336Portal ↗ | Issued Sep 30, 2024 3d review | Finaled | $1,900 | HVAC Permit: Remove and replace HVAC split system in unit 103, like for like. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: KEVIN L V SMITH |
| 6489 Valley Hi Dr 44 City of Sacramento · APN 117-0012-008-0000 | HVAC / heat pump COM-2421334Portal ↗ | Issued Sep 30, 2024 3d review | Finaled | $1,900 | HVAC Permit: Remove and replace HVAC split system in unit 44, like for like. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: KEVIN L V SMITH |
| 6565 Valley Hi Dr 99 City of Sacramento · APN 117-0012-008-0000 | HVAC / heat pump COM-2421331Portal ↗ | Issued Sep 30, 2024 3d review | Finaled | $1,900 | 6565 VALLEY HI DR #99 - C/O HVAC split system, like for like. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. ALL WORK SUBJECT TO FIELD INSPECTION. Filed as: KEVIN L V SMITH |
| 6497 Valley Hi Dr 2 City of Sacramento · APN 117-0012-008-0000 | HVAC / heat pump COM-2421330Portal ↗ | Issued Sep 30, 2024 3d review | Finaled | $1,900 | HVAC Permit: Remove and replace HVAC split system in unit 2, like for like. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: KEVIN L V SMITH |
| 6485 Valley Hi Dr 18 City of Sacramento · APN 117-0012-008-0000 | HVAC / heat pump COM-2421328Portal ↗ | Issued Sep 30, 2024 3d review | Finaled | $1,900 | 6485 VALLEY HI DR #18 - C/O HVAC split system, like for like. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. ALL WORK SUBJECT TO FIELD INSPECTION. Filed as: KEVIN L V SMITH |
| 7582 Rush River Dr 25 City of Sacramento · APN 031-1170-007-0000 | HVAC / heat pump COM-2413476Portal ↗ | Issued Jun 27, 2024 8d review | Finaled | $1,900 | HVAC Permit: Remove and replace HVAC split system in the same location, like for like. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. Filed as: KEVIN L V SMITH |
| 7639 Windbridge Dr 79 City of Sacramento · APN 031-1170-004-0000 | Roof replacement COM-2411839Portal ↗ | Applied May 30, 2024 | Expired Application | $1,900 | HVAC Permit: Tear off and replace HVAC split system in the same location, like for like. The existing unit shall be removed. The new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. CF-1R-ALT-HVAC on file: Carbon monoxide & Smoke alarms required. Reference CRC sections R315 & R314. ALL WORK SUBJECT TO FIELD INSPECTION Filed as: KEVIN L V SMITH |