Active in City of Sacramento (34 permits) · Unincorporated Marin (4 permits)
Raw permit filing aliases merged: TRI - SQUARE CONSTRUCTION CO INC · TRI-SQUARE CONSTRUCTION CO INC
35 issued · 32 parcels
vs 7 prior 24m
27 construction/remodel
Sum of permit job values
Application → issuance
Latest: Aug 6, 2026
Where this builder's geocoded permits cluster
Compares this builder's median days from permit application to issuance against all peer permits in City of Sacramento (trailing 5-year benchmark).
| Permit Category | Permits | Issued | Units | Declared Valuation | Builder Median Review | City Median (75th pct) | Relative Pace |
|---|---|---|---|---|---|---|---|
| 23 | 22 | — | $1,315,000 | 137d (n=22) | 4d (21d p75) | Above 75th pct turnaround | |
| 5 | 5 | — | $20,800 | 0d (n=5) | 0d (0d p75) | Within typical range | |
| 5 | 4 | — | $454,000 | 91d (n=4) | 33d (85d p75) | Above 75th pct turnaround | |
| 4 | 4 | — | $380,000 | 344d (n=4) | 69d (132d p75) | Above 75th pct turnaround | |
| 1 | 0 | — | — | — | 41d (93d p75) | — |
Click any address to open the full property dossier or inspect the official agency record
| Property / Parcel | Record & Category | Applied / Issued | Status | Valuation | Work Description & Raw Attribution |
|---|---|---|---|---|---|
| 4495 Mack Rd City of Sacramento · APN 119-0070-070-0000 | Other COM-2617042Portal ↗ | Issued Aug 6, 2026 0d review | Finaled | $4,000 | LIKE FOR LIKE 4 LINES OF 600 COPPER MCM REPLACEMENT. ALL WORK SUBJECT TO FIELD INSPECTION. Filed as: TRI - SQUARE CONSTRUCTION CO INC |
| 1820 Diesel Dr City of Sacramento · APN 238-0220-025-0000 | Electrical / panel COM-2616915Portal ↗ | Issued Aug 5, 2026 0d review | Finaled | $6,000 | LIKE FOR LIKE. 4 LINES OF 600 COPPER MCM FOR PG&E SERVICE LINES. PLANS ATTACHED FOR REFERENECE ONLY. ALL WORK SUBJECT TO FIELD INSPECTION. Filed as: TRI - SQUARE CONSTRUCTION CO INC |
| 120 Scripps Dr City of Sacramento · APN 295-0330-056-0000 | Electrical / panel COM-2612615Portal ↗ | Issued Jun 16, 2026 0d review | Finaled | $2,800 | Electrical Permit: Like for like cooper wire replacement cell tower. Filed as: TRI - SQUARE CONSTRUCTION CO INC |
| 3101 Connie Dr City of Sacramento · APN 266-0111-009-0000 | Electrical / panel COM-2510795Portal ↗ | Issued May 27, 2025 0d review | Finaled | $1,500 | Fix SMUD Meter box for green tag inspection due to vandalism; like for like wire repair from transformer to feeder in meter box; Jarad Olsen approved at counter conversation. Filed as: TRI - SQUARE CONSTRUCTION CO INC |
| 1500 Butterfield Rd Unincorporated Marin · APN 176-300-30 | New garage / accessory structure 178194Portal ↗ | Issued Nov 25, 2024 97d review | Issued | $35,000 | Equipment Enclosure W/ Wood Fence & Ret Wall For Pg&E Transformer And Meter Bank Assoc W/176072-3 Filed as: TRI-SQUARE CONSTRUCTION CO INC |
| 3341 Lanatt St City of Sacramento · APN 001-0170-030-0000 | Remodel / interior alteration COM-2408282Portal ↗ | Issued Nov 20, 2024 217d review | Finaled | $60,000 | EPC - Remove fire damaged pole with new pole and related equipment. Filed as: TRI - SQUARE CONSTRUCTION CO INC |
| 100 Lighthouse Rd (Aka 26450 Sfd Blvd) Unincorporated Marin · APN 109-270-08 | New garage / accessory structure 172932Portal ↗ | Issued Oct 29, 2024 845d review | Issued | $150,000 | A T&T: New Cell Site With Cabinets, Antenna Pole; Generator; H V A C Filed as: TRI-SQUARE CONSTRUCTION CO INC |
| 7465 Rush River Dr City of Sacramento · APN 031-0900-061-0000 | Other COM-2414190Portal ↗ | Applied Jun 27, 2024 | Expired Application | $30,000 | EPC - Install tower spine replacement, replace vented concealment canister, spine weldment attachment brackets, remove and replace existing canister shrouds and attachment hardware Filed as: TRI - SQUARE CONSTRUCTION CO INC |
| 1500 Butterfield Rd Unincorporated Marin · APN 176-300-30 | New garage / accessory structure 176073Portal ↗ | Issued Feb 27, 2024 341d review | Issued | $110,000 | New Verizon Telecom Facility - Faux Water Tank With Antenna Tower Within Filed as: TRI-SQUARE CONSTRUCTION CO INC |
| 1500 Butterfield Rd Unincorporated Marin · APN 176-300-30 | New garage / accessory structure 176072Portal ↗ | Issued Feb 27, 2024 347d review | Issued | $85,000 | New Verizon Telecom Facility - Fenced Equipment Area; Cabinets; Generator; Retaining Wall Filed as: TRI-SQUARE CONSTRUCTION CO INC |
| 6141 Logan St City of Sacramento · APN 038-0231-010-0000 | Electrical / panel COM-2325504Portal ↗ | Issued Dec 5, 2023 4d review | Finaled | $2,500 | Electrical Permit: Emergency electrical / meter was vandalized.200amp no weather head its an underground service. Like for like replacement. Filed as: TRI - SQUARE CONSTRUCTION CO INC |
| 5493 Carlson Dr City of Sacramento · APN 005-0010-036-0000 | Other COM-2308292Portal ↗ | Issued Sep 22, 2023 149d review | Finaled | $100,000 | EPC - Remove (E) 60' old damaged wood cell pole due to storms for (N) 60' steel cell pole. Cell equipment under a separate permit. Remove (E) chain link fence and replace with new 6' tall fence with barbed wire and (N) 6' wide access gate in the same location. Filed as: TRI - SQUARE CONSTRUCTION CO INC |
| 3250 Gardendale Rd City of Sacramento · APN 049-0042-004-0000 | Remodel / interior alteration COM-2208816Portal ↗ | Issued Jan 13, 2023 262d review | Finaled | $55,000 | EPC - T-Mobile's SC70302A Site Mod Project. Remove(6) antennas, (3) RRU's, Collar Mounts, (2) Outdoor Cabinets and all Coaxial Cables. Install (6) New Antennas, (6) New RRU's, (2) New Hybrid Cables, (N) Collar Mounts and (2) New Outdorr Cabinets. Filed as: TRI - SQUARE CONSTRUCTION CO INC |
| 2450 Venture Oaks Way City of Sacramento · APN 274-0320-040-0000 | Remodel / interior alteration COM-2104871Portal ↗ | Issued Aug 19, 2022 528d review | Finaled | $25,000 | EPC - Remove and Replace Antenna Equipment: Remove 6 existing Sprint antennas. Install 9 new Sprint antennas. Remove 6 Sprint RRU's, install 9 new Sprint RRU's. Remove 2 existing Sprint outdoor battery cabinets, install 2 new Sprint outdoor battery cabinets. Remove 3 existing hybrid cables, install 3 new 6x24 HCS cables. Filed as: TRI - SQUARE CONSTRUCTION CO INC |
| 3250 Gardendale Rd City of Sacramento · APN 049-0042-004-0000 | Other COM-2214498Portal ↗ | Issued Aug 9, 2022 32d review | Finaled | $20,000 | EPC - T-Mobile to install 480' of new 4" conduit for telco back to their existing lease area from pole AT&T meet point. T-MOBILE WOULD LIKE TO EXTEND EXISITING H-FRAME AND INSTALL NEW 24X24 TELCO BOX. Filed as: TRI - SQUARE CONSTRUCTION CO INC |
| 5700 S Land Park Dr City of Sacramento · APN 024-0161-012-0000 | Remodel / interior alteration COM-2207467Portal ↗ | Issued Jul 14, 2022 97d review | Finaled | $25,000 | EPC - A modification to an existing unmanned T-Mobile telecommunication facility consisting of removing and replacing existing 100A service meter with new 200A service meter and removing and replacing existing gen plug with new generator intersect Filed as: TRI - SQUARE CONSTRUCTION CO INC |
| 7850 Amherst St City of Sacramento · APN 052-0170-044-0000 | Remodel / interior alteration COM-2201732Portal ↗ | Issued Mar 23, 2022 58d review | Finaled | $180,000 | EPC - Proposed VZW Unmanned Telecommunication Facility: - A 12'-0'' x 19' - 0'' lease area. - Outdoor equipment cabinets - Power and telco utilities brought to facility. - A cable ice bridge. -Antennas w/ associated tower mounted equipment on an existing lattice tower. Filed as: TRI - SQUARE CONSTRUCTION CO INC |
| 3800 Bayou Rd City of Sacramento · APN 225-1480-054-0000 | Remodel / interior alteration COM-2017430Portal ↗ | Issued Mar 3, 2022 525d review | Finaled | $252,000 | EXPEDITED - EPC - New Verizon Wireless Cell site, roof top, clock tower. install antennas, with associated radio equipment. - PLNG-INSP CYC4: SWITCHING 5G ANTENNA MODEL, REVISED EXHAUST VENT ON A4.4 Filed as: TRI - SQUARE CONSTRUCTION CO INC |
| 3310 Airport Rd City of Sacramento · APN 225-0180-057-0000 | Remodel / interior alteration COM-2106253Portal ↗ | Issued Feb 3, 2022 315d review | Finaled | $30,000 | EPC - New carrier addition to existing 75' telecommunications facility: • Add Antenna/Radio mounting brackets at 56’-0” above ground level • Add nine (9) Antennas (3 per sector) • Add six (6) Radios (2 per sector) • Install concrete equipment/generator pads within existing equipment area • Add one (1) Equipment Cabinet • Add one (1) Battery Cabinet • Add one (1) 25kw Generator w/ 240gal Storage Tank • Add Power & Telco demarcation hardware and conduits Filed as: TRI - SQUARE CONSTRUCTION CO INC |
| 1230 N St City of Sacramento · APN 006-0222-028-0000 | Remodel / interior alteration COM-2123522Portal ↗ | Issued Dec 27, 2021 54d review | Expired Permit | $25,000 | EPC - Power Upgrade Only. Remove (E) conduit and conductors from (E) Service Panel. Install (N) 200A Service Meter, Disconnect and 200A Generator Interface along with (N) cabling and conduits. Filed as: TRI - SQUARE CONSTRUCTION CO INC |
| 701 Fairgrounds Dr City of Sacramento · APN 011-0380-002-0000 | Remodel / interior alteration COM-2106260Portal ↗ | Issued Dec 8, 2021 258d review | Finaled | $7,500 | EPC - Install new 2" conduit and conductors between Existing 200amp panels. Filed as: TRI - SQUARE CONSTRUCTION CO INC |
| 3950 Norwood Ave City of Sacramento · APN 250-0040-068-0000 | Remodel / interior alteration COM-2100253Portal ↗ | Issued Aug 24, 2021 230d review | Expired Permit | $45,000 | EPC - T-Mobile Cell Site Modification - Remove (3) antennas, (6) coax cables, (6) TMA units and (1) existing canister. Install (3) T-arm sector frames, (4) hybrid cables, (6) RRU's and (9) antennas. Install (1) 6160 cabinet, (1) B160 Battery cabinet, (1) PSU 4813 B160 and (4) BB 6630 units. Remove (18) RRUS and (3) triplexers. Filed as: TRI - SQUARE CONSTRUCTION CO INC |
| 6451 Power Inn Rd City of Sacramento · APN 040-0101-001-0000 | Electrical / panel COM-2020944Portal ↗ | Issued Nov 12, 2020 0d review | Finaled | $8,000 | Emergency repair to service run due to unintentional damage to include replacing conductors and conduit. Filed as: TRI - SQUARE CONSTRUCTION CO INC |
| 1900 Fruitridge Rd City of Sacramento · APN 025-0041-019-0000 | Remodel / interior alteration COM-2011691Portal ↗ | Issued Oct 6, 2020 91d review | Finaled | $10,000 | EPC - T-Mobile would like remove and replace its existing PPC pedestal with a new 200 amp distribution panel and H-Frame in their existing lease area. Filed as: TRI - SQUARE CONSTRUCTION CO INC |
| 1707 J St City of Sacramento · APN 006-0066-017-0000 | Remodel / interior alteration COM-2015135Portal ↗ | Issued Sep 21, 2020 28d review | Expired Permit | $8,000 | EPC - We are proposing to remove the existing 50 amp breaker and replace with a new 100 amp breaker in the existing 277/480 switch gear. Upgrade existing 100 amp panel to new 200 amp Filed as: TRI - SQUARE CONSTRUCTION CO INC |