Active in City of Sacramento (31 permits)
Raw permit filing name: RAMPART ENTERPRISES INC
30 issued · 25 parcels
vs 10 prior 24m(+20%)
17 construction/remodel
Sum of permit job values
Application → issuance
Latest: Sep 30, 2026
Where this builder's geocoded permits cluster
Compares this builder's median days from permit application to issuance against all peer permits in City of Sacramento (trailing 5-year benchmark).
| Permit Category | Permits | Issued | Units | Declared Valuation | Builder Median Review | City Median (75th pct) | Relative Pace |
|---|---|---|---|---|---|---|---|
| 13 | 13 | — | $601,011 | 29d (n=13) | 4d (21d p75) | Above 75th pct turnaround | |
| 12 | 12 | — | $101,001 | 1d (n=12) | 0d (0d p75) | Above 75th pct turnaround | |
| 4 | 4 | — | $395,000 | 24d (n=4) | 63d (119d p75) | Faster than peer median | |
| 1 | 1 | — | $50,000 | — | 40d (91d p75) | — | |
| 1 | 0 | — | — | — | 41d (93d p75) | — |
Click any address to open the full property dossier or inspect the official agency record
| Property / Parcel | Record & Category | Applied / Issued | Status | Valuation | Work Description & Raw Attribution |
|---|---|---|---|---|---|
| 8300 Alpine Ave City of Sacramento · APN 061-0100-013-0000 | Remodel / interior alteration COM-2618429Portal ↗ | Issued Sep 30, 2026 40d review | Issued | $43,000 | EXPEDITED - installation of A065- Jelly moulding Line remodel to include the following -- ELECTRICAL SCOPE: - Install 400 amp panel, 200 amp panel, 30 KVA transformer and 100 amp panel for new equipment. - Install aluminum feeders fro a complete operable system. PLUMBING SCOPE: Install piping for the following: - (2) Hot water pipe drops through T-bar ceiling and connect to owner supplied and installed hose reels. - (2) Cold water pipe drops through T-bar ceiling and connect to owner supplied and installed hose reels. - Relocate (1) compressed air pipe drop through T-bar ceiling approximately 30’ and connect to owner supplied and installed hose reel and air filter. - Compressed air piping and fittings (Duratec Airline) to be furnished by owner and installed by Ellis Plumbing. Filed as: RAMPART ENTERPRISES INC |
| 6320 Eichler St City of Sacramento · APN 024-0394-003-0000 | Electrical / panel RES-2618431Portal ↗ | Issued Aug 21, 2026 0d review | Issued | $2,501 | E-Permit: existing panel 200 Amps - Overhead service, new main panel 200 Amps, Replacement weather head/masthead work, main breaker replacement. Filed as: RAMPART ENTERPRISES INC |
| 415 18th St City of Sacramento · APN 003-0121-001-0000 | Electrical / panel COM-2609575Portal ↗ | Issued Jun 30, 2026 49d review | Finaled | $28,000 | EPC - Remove the Zinsco Service Disconnect, meter sections, meter main and panels. Install new insurance compliant service Disconnect, meter sections, meter/main and panels. Filed as: RAMPART ENTERPRISES INC |
| 3301 C St 1000 City of Sacramento · APN 004-0010-037-0000 | Remodel / interior alteration COM-2603208Portal ↗ | Issued Mar 13, 2026 23d review | Finaled | $7,500 | EPC - This is an all-electric scope of work which includes the following: (1) Install new 200 amp 120/208V 3 Ph Panel (2) Install new feeder from existing distribution panel to the new panel location (3) Install new receptacles for the printer equipment. NO EXTERIOR WORK. Filed as: RAMPART ENTERPRISES INC |
| 8300 Alpine Ave City of Sacramento · APN 061-0100-013-0000 | Remodel / interior alteration COM-2519219Portal ↗ | Issued Oct 10, 2025 29d review | Finaled | $45,000 | EPC - (1) Install one 1200 amp distribution panel for future use. (2) Utilize (E) 1200 amp breakers in the existing MSB. (3) Install 1200 amp aluminum feeder from the existing MSB to the new 1200 amp distribution panel. Filed as: RAMPART ENTERPRISES INC |
| 1 Wayne Ct City of Sacramento · APN 062-0060-089-0000 | Remodel / interior alteration COM-2518398Portal ↗ | Issued Oct 3, 2025 31d review | Finaled | $8,000 | EPC - There is no exterior work. Install Five (5) receptacles in the finish paint booth (two circuits). Filed as: RAMPART ENTERPRISES INC |
| 621 Capitol Mall City of Sacramento · APN 006-0151-021-0000 | Remodel / interior alteration COM-2504249Portal ↗ | Issued Jun 19, 2025 108d review | Finaled | $87,000 | EPC - (1) Installation of two dual head EV Chargers for Fleet Use Only (2) Installation of bollards and signage for new EV Chargers (3) Installation of 75KVA Transformer and 200 amp panel to support chargers. SEE REVISION COM-2516407: The layout in the Electrical Room required the contractor (Rampart Enterprises) to tap off a separate bus to maintain required clearances. Filed as: RAMPART ENTERPRISES INC |
| 3301 C St 1000 City of Sacramento | Commercial tenant improvement COM-2507492Portal ↗ | Issued May 2, 2025 18d review | Finaled | $175,000 | EPC - (1) Retrofit existing lighting fixtures with new LED lighting fixtures. (2) Provide and install new lighting controls. Filed as: RAMPART ENTERPRISES INC |
| 948 Q St City of Sacramento · APN 006-0340-025-0000 | Electrical / panel RES-2508311Portal ↗ | Issued Apr 24, 2025 0d review | Finaled | $5,000 | E-Permit: existing panel 125 Amps - Underground service, new main panel 225 Amps, N/A weather head/masthead work. Filed as: RAMPART ENTERPRISES INC |
| 92 Aiken Way City of Sacramento · APN 004-0076-011-0000 | Electrical / panel RES-2504957Portal ↗ | Issued Mar 12, 2025 0d review | Finaled | $2,501 | E-Permit: existing panel 200 Amps - Overhead service, new main panel 200 Amps, Replacement weather head/masthead work, main breaker replacement. Filed as: RAMPART ENTERPRISES INC |
| 1701 R St City of Sacramento · APN 006-0296-018-0000 | Electrical / panel COM-2428060Portal ↗ | Issued Jan 2, 2025 2d review | Finaled | $4,000 | EOTC - Mount One (1) new receptacle at approx. (14"). Filed as: RAMPART ENTERPRISES INC |
| 3950 Duckhorn Dr 110 City of Sacramento · APN 225-0140-082-0000 | EV charger COM-2413695Portal ↗ | Issued Nov 6, 2024 138d review | Finaled | $50,000 | EPC - Provide and install (1) (N) transformer 75KVA. Provide and install (1) (N) 200A panel. Provide power supply and connection to (2) HVLV Fans. Power supply and connection to (2) dual-head EV chargers. Power supply and connection to (2) single-head EV chargers. Provide code compliant striping for (6) new EV charger spaces. Provide code compliant signage for (6) new EV charger spaces. Provide and install (8) concrete bollards for (6) new EV chargers. REVISION COM-2403810:EPC - REVISION TO CALCUALTIONS DUE TO UNIT SUBSTITUTION, HEAVIER IN WEIGHT AND REDUCED ANCHOR SPACING. Filed as: RAMPART ENTERPRISES INC |
| 1 Wayne Ct City of Sacramento · APN 062-0060-089-0000 | Remodel / interior alteration COM-2419154Portal ↗ | Issued Sep 27, 2024 30d review | Finaled | $30,000 | EPC - INSTALLATION OF (1) NEW 100 AMP 277/480 VOLT PANEL. INSTALLATION OF NEW ELECTRICAL CIRCUITRY TO NEW MANUFACTURING EQUIPMENT. NEW EQUIPMENT TO BE INSTALLED ON SEPARATE PERMIT. Filed as: RAMPART ENTERPRISES INC |
| 360 Commerce Cir City of Sacramento · APN 275-0251-006-0000 | Remodel / interior alteration COM-2418157Portal ↗ | Issued Aug 16, 2024 1d review | Finaled | $21,000 | EOTC - REMOVE THE EXISTING 400 AMP 120/240 VOLT 3 PHASE (DELTA-LEG) SERVICE THAT WAS DAMAGED BY A FIRE. INSTALL NEW 400 AMP CT CABINET AND ASSOCIATED SECONDARY FEEDERS TO SMUD OVERHEAD RISER. Filed as: RAMPART ENTERPRISES INC |
| 160 Commerce Cir City of Sacramento · APN 275-0290-020-0000 | Electrical / panel COM-2411620Portal ↗ | Issued Jun 10, 2024 4d review | Finaled | $5,000 | EOTC - Provide and install (1) 200A 120/208V 3PH meter main to provide temporary power for construction. Filed as: RAMPART ENTERPRISES INC |
| 2201 Broadway City of Sacramento · APN 010-0222-018-0000 | Remodel / interior alteration COM-2319968Portal ↗ | Issued Nov 21, 2023 63d review | Finaled | $40,000 | EPC - Utilization of the existing electrical service as a temp power. The existing 1200A 277/480V service is capable of handling temporary loads defined by plan set. Temporary distributions panels and transformers will be decommissioning along with the existing main switchboard when the new 3000A 277/480V switchboard and 1600A 277/480V distribution panels arrive. Main Permit under COM-2303820 Filed as: RAMPART ENTERPRISES INC |
| 3950 Duckhorn Dr City of Sacramento · APN 225-0140-082-0000 | Commercial tenant improvement COM-2322105Portal ↗ | Issued Nov 16, 2023 30d review | Finaled | $75,000 | EPC - - Provide revised LED high bay lighting for new high pile storage. - Provide revised emergency egress lighting for new high pile storage. - Provide revised fire alarm system for new high pile storage. Filed as: RAMPART ENTERPRISES INC |
| 2231 59th St City of Sacramento · APN 011-0172-009-0000 | Electrical / panel COM-2320803Portal ↗ | Issued Oct 12, 2023 13d review | Expired Permit | $3,000 | EPC Existing service failed and SMUD removed the meter due to heat. Upgrade the service from 150A 240V 1PH to 200A 240 1PH. Facility is currently on temporary until 10/11/23. Filed as: RAMPART ENTERPRISES INC |
| 1310 H St City of Sacramento · APN 006-0053-002-0000 | Electrical / panel COM-2321356Portal ↗ | Issued Oct 6, 2023 0d review | Expired Permit | $500 | Electrical Permit: Replace the failed 400 amp main breaker. Filed as: RAMPART ENTERPRISES INC |
| 1310 H St City of Sacramento · APN 006-0053-002-0000 | Electrical / panel COM-2310543Portal ↗ | Issued May 24, 2023 0d review | Expired Permit | $40,000 | Repair vandalized SMUD secondary service - replace a customer-owned utility line that's been damaged from SMUD Vault to the building. This is like for like replacement of underground service feeders to an existing pedestal. Filed as: RAMPART ENTERPRISES INC |
| 3900 Duckhorn Dr City of Sacramento · APN 225-0140-083-0000 | Electrical / panel COM-2227059Portal ↗ | Issued Mar 1, 2023 71d review | Expired Permit | $4,000 | EPC - TEMP POWER Provide temporary power for construction. Filed as: RAMPART ENTERPRISES INC |
| 300 Capitol Mall City of Sacramento · APN 006-0142-038-0000 | Remodel / interior alteration COM-2225937Portal ↗ | Issued Jan 17, 2023 42d review | Finaled | $134,011 | EPC - Provide and install exterior accent lighting. Provide and install new lighting control system. Utilize existing electrical service and associated sub-panels. Total Site Sq ft 104,108+ - PLNG-INSP Filed as: RAMPART ENTERPRISES INC |
| 160 Main Ave City of Sacramento · APN 237-0022-046-0000 | Electrical / panel COM-2206487Portal ↗ | Issued Apr 7, 2022 8d review | Expired Permit | $5,000 | EPC. Temporary power request for COM-2205072. Warehouse 43050 sqft for Triple AAA facilities. Filed as: RAMPART ENTERPRISES INC |
| 1715 R St City of Sacramento · APN 006-0296-018-0000 | Remodel / interior alteration COM-2112567Portal ↗ | Issued Jun 16, 2021 5d review | Finaled | $7,000 | EXPEDITED - EPC - EOTC - Install a new Submeter adjacent to the house panel. Install a 30AMP Twist Lock Receptacle + 20AMP 120V Receptacle that will be mounted to a steel post. Feed by the existing house panel via existing underground conduit. Filed as: RAMPART ENTERPRISES INC |
| 431 16th St City of Sacramento · APN 002-0133-022-0000 | Electrical / panel COM-2007048Portal ↗ | Issued Apr 29, 2020 0d review | Finaled | $1,500 | Replace Breaker Filed as: RAMPART ENTERPRISES INC |